DIFFERENTIAL-PULSE VOLTAMMETRIC DETERMINATION OF LEAD(II) WITH BENZOIN OXIME-MODIFIED CARBON-PASTE ELECTRODES

被引:0
|
作者
PENG, TZ
TANG, Z
WANG, GS
SHEN, BE
机构
关键词
CHEMICALLY MODIFIED ELECTRODE; STRIPPING VOLTAMMETRY; LEAD; BENZOIN OXIME;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new chemically modified electrode (CME) for determining lead(II) with high sensitivity and selectivity is reported. The electrode is constructed by adding benzoin oxime into a carbon paste mixture. The lead(II) is accumulated on the electrode surface by the formation of the complex in an open circuit, and then the resulting surface is characterized by medium exchange, potential reduction, and differential pulse anodic stripping voltammetry. In 10 deposition/measurement/regeneration cycles with a single surface, the response could be reproduced with 5.7% relative standard deviation. Quantitation of lead(II) from the peak current of the anodic wave for a 10 minute deposition time gives a detection limit of 8 x 10(-9) M (1.6 ppb). Linear calibration plots are obtained for lead(II) dconcentrations ranging from 10(-7) to 10(-8) M. The modified electrode preferentially accumulates lead from the solution, while most of the metal ions do not interfere with the determination. The mechanism of the accumulation of lead on the benzoin oxime-modified electrode has been explored. Application to the determination of lead in wastewater is illustrated.
引用
收藏
页码:597 / 603
页数:7
相关论文
共 50 条
  • [1] DIFFERENTIAL-PULSE STRIPPING VOLTAMMETRIC DETERMINATION OF THALLIUM WITH AN 8-HYDROXYQUINOLINE-MODIFIED CARBON-PASTE ELECTRODE
    CAI, QT
    KHOO, SB
    [J]. ELECTROANALYSIS, 1995, 7 (04) : 379 - 385
  • [2] PRECONCENTRATION AND DIFFERENTIAL-PULSE VOLTAMMETRIC DETERMINATION OF IRON(II) WITH NAFION 1,10-PHENANTHROLINE-MODIFIED CARBON PASTE ELECTRODES
    ZHIQIANG, G
    PEIBIAO, L
    GUANGQING, W
    ZAOFAN, Z
    [J]. ANALYTICA CHIMICA ACTA, 1990, 241 (01) : 137 - 146
  • [3] VOLTAMMETRIC DETERMINATION OF LEAD WITH A CHEMICALLY-MODIFIED CARBON-PASTE ELECTRODE WITH DIPHENYLTHIOCARBAZONE
    MOLINAHOLGADO, T
    PINILLAMACIAS, JM
    HERNANDEZHERNANDEZ, L
    [J]. ANALYTICA CHIMICA ACTA, 1995, 309 (1-3) : 117 - 122
  • [4] VOLTAMMETRIC DETERMINATION OF NITRATE WITH A MODIFIED CARBON-PASTE ELECTRODE
    NEUHOLD, C
    KALCHER, K
    DIEWALD, W
    CAI, XH
    RABER, G
    [J]. ELECTROANALYSIS, 1994, 6 (03) : 227 - 236
  • [5] VOLTAMMETRIC CHARACTERIZATION OF ACTIVATED CARBONS IN MODIFIED CARBON-PASTE ELECTRODES
    KAPLAN, JD
    MARSH, JH
    ORCHARD, SW
    [J]. ELECTROANALYSIS, 1993, 5 (5-6) : 509 - 516
  • [6] DETERMINATION OF IRON(II) WITH CHEMICALLY-MODIFIED CARBON-PASTE ELECTRODES
    GAO, ZQ
    LI, PB
    ZHAO, ZF
    [J]. TALANTA, 1991, 38 (10) : 1177 - 1184
  • [7] Preconcentration and voltammetric determination of nitro compounds on carbon-paste electrodes
    Sapel'nikova, S.V.
    Kuz'mina, N.V.
    Majstrenko, V.N.
    Kudasheva, F.Kh.
    [J]. Zhurnal Analiticheskoj Khimii, 2002, 57 (05): : 532 - 538
  • [8] Preconcentration and Voltammetric Determination of Nitro Compounds on Carbon-Paste Electrodes
    S. V. Sapel'nikova
    N. V. Kuz'mina
    V. N. Maistrenko
    F. Kh. Kudasheva
    [J]. Journal of Analytical Chemistry, 2002, 57 : 443 - 447
  • [9] Preconcentration and voltammetric determination of nitro compounds on carbon-paste electrodes
    Sapel'nikova, SV
    Kuz'mina, NV
    Maistrenko, VN
    Kudasheva, FK
    [J]. JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 57 (05) : 443 - 447
  • [10] Differential-pulse voltammetric determination of clenbuterol in bovine urine using a nafion-modified carbon paste electrode
    Moane, S
    Smyth, MR
    OKeeffe, M
    [J]. ANALYST, 1996, 121 (06) : 779 - 784