CLINICAL-EVALUATION OF A NOVEL AMBULATORY AUTOMATIC BLOOD-PRESSURE MONITORING-SYSTEM

被引:0
|
作者
MODESTI, PA
GENSINI, GF
BROGI, E
SERNERI, GGN
机构
[1] Clinica Medica I, University of Florence, Florence
关键词
D O I
10.1177/000331979004101007
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Reliability and reproducibility of a new automatic ambulatory blood pressure recorder were tested on 31 subjects (18 normotensives and 13 hypertensives). Of 3688 recordings, 1424 measurements were cross-checked with a sphygmomanom eter in standing or sitting position at the beginning and at the end of a twenty-four hour monitoring period. In the normotensive subjects cross-checkings were performed also during a treadmill exercise stress test. Analysis of variance did not indicate statistical differences between the two types of measurement (p>0.09 for systolic and p>0.62 for diastolic), and a significant linear correlation was found at rest (r = 0.99, p<0.001 for systolic and r = 0.98, p<0.001 for diastolic pressure). During the effort test the device was unable to correctly measure blood pressure values after the first step. During the twenty-four hour monitoring period only 1.1 % of the preprogrammed measurements were lost for each subject. The recorder seems to be a suitable and reliable tool for automatic blood pressure monitoring. © 1990, Sage Publications. All rights reserved.
引用
收藏
页码:855 / 861
页数:7
相关论文
共 50 条
  • [1] CLINICAL-EVALUATION OF AN AUTOMATIC BLOOD-PRESSURE MONITORING DEVICE
    MODESTI, PA
    GENSINI, GF
    CONTI, C
    SERNERI, GGN
    [J]. JOURNAL OF CLINICAL HYPERTENSION, 1987, 3 (04): : 631 - 644
  • [2] A CLINICAL-EVALUATION OF THE ACCUTRACKER - A LIGHTWEIGHT AMBULATORY BLOOD-PRESSURE MONITOR
    PHILLIPS, DIW
    BRAITHWAITE, J
    NEWCOMBE, RG
    LAZARUS, JH
    [J]. JOURNAL OF HUMAN HYPERTENSION, 1989, 3 (06) : 463 - 465
  • [3] MULTICENTER EVALUATION OF A CONTINUOUS NONINVASIVE BLOOD-PRESSURE MONITORING-SYSTEM
    YOUNG, C
    VENDER, J
    FLEMING, A
    DEBREE, A
    WHITE, W
    [J]. ANESTHESIOLOGY, 1993, 79 (3A) : A501 - A501
  • [4] COMPUTERIZED AUTOMATIC NON-INVASIVE BLOOD-PRESSURE MONITORING-SYSTEM
    FARSANG, C
    ALFOLDI, A
    KISMARTYLECHNER, I
    KISS, I
    VARGA, K
    [J]. ACTA MEDICA HUNGARICA, 1988, 45 (3-4) : 329 - 338
  • [5] AUTOMATIC AMBULATORY BLOOD-PRESSURE MONITORING IN THE HOSPITAL
    HOLLENSTEIN, U
    TAMMEN, AT
    BURKHARDT, V
    FELDHOFF, A
    BLUMCHEN, G
    [J]. HERZ, 1989, 14 (04) : 238 - 245
  • [6] CLINICAL-EVALUATION OF BLOOD-PRESSURE IN ALCOHOLICS
    SCHNALL, C
    WIENER, JS
    [J]. QUARTERLY JOURNAL OF STUDIES ON ALCOHOL, 1958, 19 (03): : 432 - 446
  • [7] AUTOMATIC BLOOD-PRESSURE MONITORS - A CLINICAL-EVALUATION OF 5 MODELS IN ADULTS
    JOHNSON, CJH
    KERR, JH
    [J]. ANAESTHESIA, 1985, 40 (05) : 471 - 478
  • [8] THE DIAGNOSTIC IMPACT OF AUTOMATIC AMBULATORY BLOOD-PRESSURE MONITORING
    WORTMANN, A
    KUHNLE, K
    BACHMANN, K
    [J]. JOURNAL OF HYPERTENSION, 1985, 3 (04) : 403 - 403
  • [9] CLINICAL USEFULNESS OF AMBULATORY BLOOD-PRESSURE MONITORING
    WHITE, WB
    GRIN, JM
    MCCABE, EJ
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 1993, 6 (06) : S225 - S228
  • [10] CLINICAL USES OF AMBULATORY BLOOD-PRESSURE MONITORING
    PORTMAN, RJ
    YETMAN, RJ
    [J]. PEDIATRIC NEPHROLOGY, 1994, 8 (03) : 367 - 376