MULTICENTER EVALUATION OF A NEW RECOMBINANT ENZYME-IMMUNOASSAY FOR THE COMBINED DETECTION OF ANTIBODY TO HIV-1 AND HIV-2

被引:23
|
作者
AYRES, L
AVILLEZ, F
GARCIABENITO, A
DEINHARDT, F
GURTLER, L
DENIS, F
LEONARD, G
RANGER, S
GROB, P
JOLLERJEMELKA, H
HESS, G
SEIDL, S
FLACKE, H
SIMON, F
BRUNVEZINET, F
SONDAG, D
ANDRE, A
HAMPL, H
SCHOEN, R
STRAMER, S
TROONEN, H
机构
[1] ABBOTT GMBH,DIAGNOST,MAX PLANCK RING 2,W-6200 WIESBADEN,GERMANY
[2] NATL INST HLTH,LISBON,PORTUGAL
[3] UNIV MUNICH,MAX VONPETTENKOFER INST,W-8000 MUNICH 2,GERMANY
[4] BICHAT CLAUDE BERNARD HOSP,DEPT VIROL,PARIS,FRANCE
[5] STATE UNIV LIEGE,RED CROSS BLOOD DONOR SERV,B-4000 LIEGE,BELGIUM
[6] CTR HOSP REG UNIV DUPUYTREN,DEPT VIROL,LIMOGES,FRANCE
[7] UNIV HOSP ZURICH,DEPT INTERNAL MED,CLIN IMMUNOL SECT,CH-8091 ZURICH,SWITZERLAND
[8] UNIV MAINZ,DEPT INTERNAL MED,W-6500 MAINZ,GERMANY
[9] UNIV FRANKFURT,RED CROSS BLOOD DONOR SERV,W-6000 FRANKFURT,GERMANY
关键词
anti-HIV-1/HIV-2 enzyme immunoassay; multicenter study;
D O I
10.1097/00002030-199002000-00006
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
A newly developed recombinant antigen-based anti-HIV-1/HIV-2 enzyme immunoassay (Abbott Recombinant HIV-1/HIV-2 EIA) was evaluated against a second generation anti-HIV-1 EIA (Abbott Recombinant HIV-1 EIA). Five thousand and twenty-nine sera from European blood donors and 403 sera from central African blood donors were used in the evaluation, along with four panels and one cohort. The panels included 99 'problem' sera, 733 sera with antibodies to HIV-1 from asymptomatic people and from patients at different disease stages, 25 serial bleeds from five plasmapheresis donors seroconverting for antibodies to HIV-1, and 202 sera with antibodies to HIV-2 collected from healthy and diseased people of European or west African origin. In addition, 734 sera collected from a west African cohort were tested. Using Western blots as the reference standard, the specificity obtained by the recombinant anti-HIV-1 EIA (HIV-(i) EIA) was 99.90% [99.81-99.99%; 95% confidence limits (95% CL)] with European blood donor sera; 99.50% (98.78-100%) with Central African blood donor sera; 92.93% (87.78-98.08%) with 'problem' sera and 99.43% (98.78-100%) with sera from a west African cohort. Using the same samples, the recombinant anti-HIV-1/HIV-2 EIA (HIV-1/HIV-2 EIA) yielded a specificity of 99.84% (99.73-99.95%), 99.50% (98.78-100%), 95.96% (92.00-99.92%) and 98.58% (97.69-99.47%), respectively. All 776 Western blot-confirmed anti-HIV-1 sera were reactive in both EIAs, and the EIA-reactive samples from seroconverting plasma donors were always observed for both assays in the same serial bleed. For HIV-2, the HIV-1 EIA yielded an overall sensitivity of 75.83% (69.93-81.72%) compared with 99.53% (98.58-100%) for HIV-1/HIV-2 EIA. The addition of a recombinant env-protein of HIV-2 to the recombinant env and core proteins of HIV-1 on the solid phase of HIV-1 EIA improved the detection of anti-HIV-2 while preserving the assay's overall specificity and sensitivity for the detection of anti-HIV-1.
引用
收藏
页码:131 / 138
页数:8
相关论文
共 50 条
  • [1] EFFICACY OF THE ABBOTT RECOMBINANT HIV-1/HIV-2 ENZYME-IMMUNOASSAY FOR THE DETECTION OF HIV ANTIBODIES
    GERSHYDAMET, GM
    KODJO, M
    BENOIT, S
    [J]. AIDS, 1990, 4 (01) : 87 - 88
  • [2] COMPARATIVE-EVALUATION OF ENZYME-IMMUNOASSAY SYSTEMS FOR HIV-1 AND HIV-2 INFECTIONS
    GOLOSOVA, TV
    TUPOLEVA, TA
    MARGOLINA, AN
    [J]. GEMATOLOGIYA I TRANSFUZIOLOGIYA, 1991, 36 (02): : 37 - 38
  • [3] EVALUATION OF AN ENZYME-IMMUNOASSAY FOR THE COMBINED DETECTION OF ANTIBODIES TO HIV-1, HIV-2, HTLV-I AND HTLV-II
    MCALPINE, L
    PARRY, JV
    TOSSWILL, JHC
    [J]. AIDS, 1992, 6 (04) : 387 - 391
  • [4] A SYNTHETIC PEPTIDE BASED ENZYME-IMMUNOASSAY FOR THE SIMULTANEOUS DETECTION OF ANTIBODIES TO HIV-1 AND HIV-2
    DATI, F
    BUCK, T
    [J]. CLINICAL CHEMISTRY, 1990, 36 (06) : 1090 - 1091
  • [5] Performance evaluation of the HIV-1/HIV-2 PLUS EIA, an improved enzyme immunoassay for detection of human antibody to HIV-1 (Groups M and O) and HIV-2
    Shriver, K
    Shores, P
    Nelson, S
    Davis, G
    Morgan, J
    Coleman, P
    Monji, N
    Joseph, M
    Cole, C
    Bentsen, C
    Ferrera, C
    Gadelle, S
    [J]. TRANSFUSION, 2001, 41 (09) : 78S - 79S
  • [6] The HIV-1/HIV-2 plus EIA: An improved enzyme immunoassay for detection of human antibody to HIV-1 (groups M and O) and HIV-2
    Shriver, K
    Shores, P
    Nelson, S
    Gadelle, S
    Monji, N
    Ferrera, CA
    Bentsen, C
    Coleman, P
    Foerder, CA
    [J]. TRANSFUSION, 2000, 40 (10) : 87S - 87S
  • [7] DETECTION OF ANTIBODY IGG TO HIV-1 IN URINE BY SENSITIVE ENZYME-IMMUNOASSAY (IMMUNE-COMPLEX TRANSFER ENZYME-IMMUNOASSAY) USING RECOMBINANT PROTEINS AS ANTIGENS FOR DIAGNOSIS OF HIV-1 INFECTION
    HASHIDA, S
    HIROTA, K
    HASHINAKA, K
    SAITOH, A
    NAKATA, A
    SHINAGAWA, H
    OKA, S
    SHIMADA, K
    MIMAYA, J
    MATSUSHITA, S
    ISHIKAWA, E
    [J]. JOURNAL OF CLINICAL LABORATORY ANALYSIS, 1993, 7 (06) : 353 - 364
  • [8] A CAPTURE ENZYME-IMMUNOASSAY FOR DETECTION OF HIV-2 SIV ANTIGEN
    THORSTENSSON, R
    WALTHER, L
    PUTKONEN, P
    ALBERT, J
    BIBERFELD, G
    [J]. JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES AND HUMAN RETROVIROLOGY, 1991, 4 (04): : 374 - 379
  • [9] A recombinant protein based immunoassay for the combined detection of antibodies to HIV-1, HIV-2 and HTLV-I
    Benitez, J
    Palenzuela, D
    Rivero, J
    Gavilondo, JV
    [J]. JOURNAL OF VIROLOGICAL METHODS, 1998, 70 (01) : 85 - 91
  • [10] Importance of an Early HIV Antibody Differentiation Immunoassay for Detection of Dual Infection with HIV-1 and HIV-2
    Zbinden, Andrea
    Durig, Roland
    Shah, Cyril
    Boni, Jurg
    Schupbach, Jorg
    [J]. PLOS ONE, 2016, 11 (06):