EVALUATION OF A LOCAL MICROSPHERE INJECTION METHOD FOR MEASUREMENT OF BLOOD-FLOW IN THE RABBIT LOWER-EXTREMITY

被引:4
|
作者
MAKI, Y
BREIDENBACH, WC
FIRRELL, JC
机构
[1] CHRISTINE M KLEINERT INST HAND & MICROSURG,1 MED CTR PLAZA,SUITE 850,225 ABRAHAM FLEXNER WAY,LOUISVILLE,KY 40202
[2] UNIV LOUISVILLE,HLTH SCI CTR,SCH MED,LOUISVILLE,KY 40202
关键词
D O I
10.1002/jor.1100110104
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The precision of a modified microsphere technique to measure blood flow in the hind limb of the rabbit was determined. Regional (local) injections made via a catheter in the aorta and blood withdrawn through a catheter in the hind limb enabled deposition of a high concentration of microspheres in the tissues while minimizing the number of microspheres needed for accurate measurement. Niobium-95 and cerium-141-labeled 16 mum diameter microspheres were used. Blood flow was measured in 15 locations of muscle and skin for simultaneous injections into the aorta and left ventricle (group A), simultaneous injections of a mixture into the left ventricle (group B), and ventricular injections given 1 h apart (group C). No significant differences in mean blood flow measurements were found. Correlation coefficients between local and ventricular injections ranged from 0.89-0.99 and between 0.994 and 0.999 for two simultaneous ventricular injections. The variability over time was greater, with correlations between the first and second injections ranging from 0.13-0.939. Precision of the local technique compared with the ventricular technique can be kept within 30% with five or six animals. The advantage of this technique over ventricular injections is in the measurement of blood flow in small tissue samples when the number of microspheres deposited from ventricular injections is insufficient.
引用
收藏
页码:20 / 27
页数:8
相关论文
共 50 条
  • [1] ANGIOCINEDENSITOMETRY IN MEASUREMENT OF BLOOD-FLOW IN LOWER-EXTREMITY
    ITZCHAK, Y
    YERUSHALMI, S
    ADAR, R
    MODAN, M
    DEUTSCH, V
    [J]. HAREFUAH, 1978, 95 (08) : 241 - 244
  • [2] A NEW METHOD OF ASSESSMENT OF BLOOD-FLOW IN LOWER-EXTREMITY VEINS
    LYTKIN, MI
    VEDENSKI, AN
    STOIKO, YM
    SINGAEVSKI, AB
    [J]. VESTNIK KHIRURGII IMENI I I GREKOVA, 1990, 144 (02): : 115 - 117
  • [3] LUMBAR SYMPATHECTOMY AND BLOOD-FLOW IN LOWER-EXTREMITY
    MASUOKA, S
    SHIMOMURA, T
    [J]. AMERICAN JOURNAL OF SURGERY, 1978, 136 (03): : 369 - 374
  • [4] EVALUATION OF A LOCAL INJECTION TECHNIQUE FOR MICROSPHERE DETERMINATION OF BLOOD-FLOW
    MAKI, Y
    BREIDENBACH, WC
    FIRRELL, JC
    [J]. FASEB JOURNAL, 1988, 2 (06): : A1872 - A1872
  • [5] MEASUREMENT OF BLOOD-PRESSURE, BLOOD-FLOW AND FLOW VELOCITY IN ARTERIAL RECONSTRUCTION OF THE LOWER-EXTREMITY
    SHIONOYA, S
    MATSUBARA, J
    HIRAI, M
    KAWAI, S
    SEKO, T
    SAKURAI, T
    BAN, I
    [J]. ANGIOLOGY, 1983, 34 (04) : 244 - 256
  • [6] GRAVITATIONAL EFFECTS ON BLOOD-FLOW TO ATHEROSCLEROTIC LOWER-EXTREMITY
    GIRON, F
    DERBY, AR
    JUNIOR, J
    [J]. JOURNAL OF SURGICAL RESEARCH, 1977, 23 (02) : 82 - 87
  • [7] LASER DOPPLER MEASUREMENT OF LOWER-EXTREMITY MICROVASCULAR BLOOD-FLOW IN A NEONATE WITH INTRAARTERIAL THROMBOSIS
    JOHNSON, DE
    THOMPSON, TR
    GEORGIEFF, MK
    BASS, J
    [J]. PEDIATRIC RESEARCH, 1987, 21 (04) : A364 - A364
  • [8] SKIN BLOOD-FLOW MEASUREMENT WITH XE-133 TO PREDICT HEALING OF LOWER-EXTREMITY AMPUTATIONS
    HARRIS, JP
    MCLAUGHLIN, AF
    QUINN, RJ
    PAGE, S
    MAY, J
    [J]. AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 1986, 56 (05): : 413 - 415
  • [9] HYPEREMIA IN RELATION TO PREVIOUS ISCHEMIA - BLOOD-FLOW RESPONSE IN THE LOWER-EXTREMITY
    BESTE, KW
    GRAUBNER, J
    [J]. HERZ KREISLAUF, 1987, 19 (10): : 483 - 486
  • [10] PROOF OF POISEUILLE LAW FOR DETERMINING LOWER-EXTREMITY BLOOD-FLOW AND PRESSURE
    CAESAR, MA
    BRODKIN, R
    HANLEY, D
    KIDAWA, AS
    DAVIS, RH
    [J]. JOURNAL OF THE AMERICAN PODIATRY ASSOCIATION, 1984, 74 (04): : 173 - 186