MONITORING FREE-WATER EVAPORATION AT AUTOMATED WEATHER STATIONS

被引:0
|
作者
MCGINN, SM
MCLEAN, HDJ
机构
关键词
D O I
10.1175/1520-0426(1995)012<1363:MFWEAA>2.0.CO;2
中图分类号
P75 [海洋工程];
学科分类号
0814 ; 081505 ; 0824 ; 082401 ;
摘要
The automation of weather stations necessitates an alternative approach to the traditional manual measure of free-water evaporation made using a class A pan. This study compared commercially available water-level sensing transducers mounted on class A pans to manual measurements using a class A pan. Measurements of free-water evaporation with two automated transducers over a 24-h period resulted in mean differences of 0.23 and 0.98 mm. Hourly measurements for free-water evaporation allowed examination of the correlation between principal weather elements and evaporation. Evaporation from the pan was highly correlated with wind speed at night (r = 0.86) and with air temperature during the day (r = 0.75). In addition, it was found that during the summer some 33% of the daily free-water evaporation occurred at night. For a 24-h period, accumulated free-water evaporation was highly correlated with air temperature (r = 0.85), net radiation (r = 0.81), incoming solar radiation (r = 0.80), and wind speed (r = 0.69).
引用
收藏
页码:1363 / 1366
页数:4
相关论文
共 50 条