A virtual reality simulator for hysteroscopic placement of tubal sterilization micro-inserts: the face and construct validity

被引:6
|
作者
Janse, Julienne A. [1 ]
Veersema, Sebastiaan [1 ]
Broekmans, Frank J. [2 ]
Schreuder, Henk W. R. [2 ]
机构
[1] Sint Antonius Hosp Nieuwegein, Dept Gynecol & Obstet, Koekoekslaan 1, NL-3435 CM Nieuwegein, Netherlands
[2] Univ Med Ctr Utrecht, Div Woman & Baby, NL-3508 GA Utrecht, Netherlands
关键词
Hysteroscopy; Training; Sterilizatio; Essure((R)); Virtual reality;
D O I
10.1007/s10397-013-0790-8
中图分类号
R61 [外科手术学];
学科分类号
摘要
This study investigated the validity of a virtual reality simulator for hysteroscopic tubal sterilization. Initially performed laparoscopically, the hysteroscopic sterilization method is becoming increasingly popular. An adequate training model could enhance one's skills prior to the start of performing the procedure on the real patient. This prospective study (Canadian Task force II-2) enrolled 69 residents and gynecologists who were divided into three groups, based on vaginoscopic hysteroscopy and Essure((R)) experience level: novices (N = 17), intermediates (N = 35), and experts (N = 17). Participants completed two cases on a virtual reality simulator (EssureSim (TM)) in which four Essure((R)) placements were performed. A questionnaire was completed to assess face validity, and reality scores were given on a 5-point Likert scale. Construct validity was represented by the ability of six simulator-derived parameters to significantly differentiate between different hysteroscopic experience levels. Reality of the sterilization procedure was scored with a median of 5.00 points on a 5-point Likert scale by all participants with prior sterilization experience. Of these participants, 95.5 % indicated the simulator as a useful preparation for real-time Essure((R))placement. The expert and intermediate group performed both cases significantly faster than novices (p=. 001). The novices had a significantly longer path length in comparison to the other groups (p=. 006). Analysis of the remaining parameters did not show a persistent ability to differentiate between experience levels. Satisfactory validity was demonstrated for the EssureSim (TM) by high reality scores and moderate ability to distinguish between different performance levels.
引用
收藏
页码:181 / 188
页数:8
相关论文
共 50 条
  • [1] Hysteroscopic placement of tubal sterilization micro-inserts on a virtual reality simulator: assessment of the learning curve
    Janse, J. A.
    Goedegebuure, R. S. A.
    Veersema, S.
    Broekmans, F. J. M.
    Schreuder, H. W. R.
    [J]. HUMAN REPRODUCTION, 2012, 27
  • [2] Hysteroscopic placement of tubal sterilization implants: virtual reality simulator training
    Pierre Panel
    Michael Bajka
    Arnaud Le Tohic
    Alaa El Ghoneimi
    Carmen Chis
    Stéphane Cotin
    [J]. Surgical Endoscopy, 2012, 26 : 1986 - 1996
  • [3] Hysteroscopic placement of tubal sterilization implants: virtual reality simulator training
    Panel, Pierre
    Bajka, Michael
    Le Tohic, Arnaud
    El Ghoneimi, Alaa
    Chis, Carmen
    Cotin, Stephane
    [J]. SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2012, 26 (07): : 1986 - 1996
  • [4] Construct and face validity of SINERGIA laparoscopic virtual reality simulator
    Luisa F. Sánchez-Peralta
    Francisco M. Sánchez-Margallo
    José Luis Moyano-Cuevas
    José Blas Pagador
    Silvia Enciso-Sanz
    Patricia Sánchez-González
    Enrique J. Gómez-Aguilera
    Jesús Usón-Gargallo
    [J]. International Journal of Computer Assisted Radiology and Surgery, 2010, 5 : 307 - 315
  • [5] Construct and face validity of SINERGIA laparoscopic virtual reality simulator
    Sanchez-Peralta, Luisa F.
    Sanchez-Margallo, Francisco M.
    Moyano-Cuevas, Jose Luis
    Blas Pagador, Jose
    Enciso-Sanz, Silvia
    Sanchez-Gonzalez, Patricia
    Gomez-Aguilera, Enrique J.
    Uson-Gargallo, Jesus
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2010, 5 (04) : 307 - 315
  • [6] Face validity, construct validity and training benefits of a virtual reality turp simulator
    Bright, Elizabeth
    Vine, Samuel
    Wilson, Mark R.
    Masters, Rich S. W.
    McGrath, John S.
    [J]. INTERNATIONAL JOURNAL OF SURGERY, 2012, 10 (03) : 163 - 166
  • [7] Face, content and construct validity of a virtual reality simulator for robotic surgery
    Gavazzi, A.
    Bahsoun, A.
    Van Haute, W.
    Khan, M. S.
    Dasgupta, P.
    [J]. BRITISH JOURNAL OF SURGERY, 2011, 98 : 51 - 51
  • [8] Face and construct validity of a computer-based virtual reality simulator for ERCP
    Bittner, James G.
    Mellinger, John D.
    Imam, Toufic
    Schade, Robert R.
    MacFadyen, Bruce V., Jr.
    [J]. GASTROINTESTINAL ENDOSCOPY, 2010, 71 (02) : 357 - 364
  • [9] A pilot study to evaluate the face & construct validity of an orthopaedic virtual reality simulator
    Feeley, Aoife
    Feeley, Iain
    Merghani, Khalid
    Sheehan, Eoin
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2021, 52 (07): : 1715 - 1720
  • [10] Face and content validity of a virtual-reality simulator for myringotomy with tube placement
    Caiwen Huang
    Horace Cheng
    Yves Bureau
    Sumit K. Agrawal
    Hanif M. Ladak
    [J]. Journal of Otolaryngology - Head & Neck Surgery, 44