PRECISION OF NONINVASIVE TEMPERATURE-MEASUREMENT BY DIFFUSE-REFLECTANCE SPECTROSCOPY

被引:22
|
作者
PEARSALL, TP
SABAN, SR
BOOTH, J
BEARD, BT
JOHNSON, SR
机构
[1] THERMIONICS NW,PORT TOWNSEND,WA 98368
[2] UNIV BRITISH COLUMBIA,DEPT PHYS,VANCOUVER,BC V6T 1Z1,CANADA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1995年 / 66卷 / 10期
关键词
D O I
10.1063/1.1146184
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Diffuse reflectance spectroscopy can be used as a noninvasive probe for measurement of temperature in real time. We have measured the precision of this technique to determine the temperature of Si and GaAs substrates during semiconductor processing. Our results show that the standard deviation of the noninvasive optical technique is less than 1.5 degrees C for GaAs and less than 2.0 degrees C for Si over the temperature range 25 degrees C<T<600 degrees C. This standard deviation compares favorably to that for a type-a thermocouple used in the same measurements: s.d.<1.5 degrees C. These results support the notion that noninvasive optical temperature measurement can be used in semiconductor processing with a precision approaching that of a thermocouple. (C) 1995 American Institute of Physics.
引用
收藏
页码:4977 / 4980
页数:4
相关论文
共 50 条
  • [1] In vivo noninvasive measurement of blood glucose by near-infrared diffuse-reflectance spectroscopy
    Maruo, K
    Tsurugi, M
    Tamura, M
    Ozaki, Y
    APPLIED SPECTROSCOPY, 2003, 57 (10) : 1236 - 1244
  • [2] DIFFUSE-REFLECTANCE SPECTROSCOPY IN THE INFRARED
    MAULHARDT, H
    KUNATH, D
    TALANTA, 1982, 29 (03) : 237 - 241
  • [3] Precision of non-invasive temperature measurement by diffuse reflectance spectroscopy
    Wang, ZZ
    Kwan, SL
    Pearsall, TP
    Booth, J
    Beard, BT
    Johnson, SR
    DIAGNOSTIC TECHNIQUES FOR SEMICONDUCTOR MATERIALS PROCESSING II, 1996, 406 : 69 - 74
  • [4] DIFFUSE-REFLECTANCE INFRARED-SPECTROSCOPY
    RAYMOND, KW
    CORKILL, JA
    JOURNAL OF CHEMICAL EDUCATION, 1994, 71 (08) : A204 - A204
  • [5] Diffuse-reflectance infrared spectroscopy - Theory and application
    Hrebicik, M
    Volka, K
    CHEMICKE LISTY, 1996, 90 (02): : 80 - 92
  • [6] OPTIMIZATION OF SAMPLE PACKING IN DIFFUSE-REFLECTANCE INFRARED-SPECTROSCOPY
    KRIVACSY, Z
    HLAVAY, J
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 1994, 50 (01): : 49 - 55
  • [7] FEMTOSECOND DIFFUSE-REFLECTANCE SPECTROSCOPY OF TIO2 POWDERS
    COLOMBO, DP
    BOWMAN, RM
    JOURNAL OF PHYSICAL CHEMISTRY, 1995, 99 (30): : 11752 - 11756
  • [8] NONINVASIVE BLOOD-GLUCOSE ASSAY BY NEAR-INFRARED DIFFUSE-REFLECTANCE SPECTROSCOPY OF THE HUMAN INNER LIP
    MARBACH, R
    KOSCHINSKY, T
    GRIES, FA
    HEISE, HM
    APPLIED SPECTROSCOPY, 1993, 47 (07) : 875 - 881
  • [9] TEMPERATURE-MEASUREMENT BY ABSORPTION SPECTROSCOPY
    SALOMAA, R
    BYCKLING, E
    AMERICAN LABORATORY, 1977, 9 (11) : 52 - &
  • [10] Noninvasive Measurement of the Glucose Level in Biological Media Based on Diffuse Reflectance Spectroscopy
    Pozhar, K. V.
    Mikhailov, M. O.
    Polyakova, E. A.
    Litinskaia, E. L.
    Abolemova, Yu. E.
    BIOMEDICAL ENGINEERING-MEDITSINSKAYA TEKNIKA, 2021, 55 (02): : 84 - 88