ASSESSMENT OF AN AURAL INFRARED-SENSOR FOR BODY-TEMPERATURE MEASUREMENT IN CHILDREN

被引:42
|
作者
RHOADS, FA [1 ]
GRANDNER, J [1 ]
机构
[1] CHILDRENS NATL MED CTR,CTR GEN PEDIAT AMBULATORY,WASHINGTON,DC
关键词
D O I
10.1177/000992289002900209
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
A newly marketed device measures body temperature using an ear probe that detects infrared radiation from the tympanic membrane. It is simple to use and gives a reading in 1-2 seconds. Its accuracy was evaluated in a group of children, aged 1 month through 10 years, by comparing it with either rectal (n = 65), or oral (n = 48) temperatures obtained with a standard electronic thermometer, IVAC (San Diego, CA). The average elapsed time between readings was 11 minutes. Overall, 60 rectal and 40 oral temperatures (88.5%) were higher with IVAC than with the aural sensor. The difference ranged from -0.7°C to +2.5°C. The correlations between the infrared ear-probe values and the rectal and oral temperature readings were 0.77 and 0.75, respectively. Because the average reading using the aural sensor was lower than that using the IVAC, the sensitivity of the aural sensor for detecting clinically important levels of fever was low. None of seven patients with a rectal temperature of 39°C or more and only 7 of 27 with a rectal temperature of 38°C or more were identified by the aural sensor as having temperatures above these cutoff levels. Similarly, none of three patients with an oral temperature of 39°C or more and only three of eight with an oral temperature of 38°C or more were identified correctly by the aural sensor. The authors conclude that the aural sensor is unsatisfactory for detecting clinically significant fevers in a pediatric outpatient setting. © 1990, Sage Publications. All rights reserved.
引用
收藏
页码:112 / 115
页数:4
相关论文
共 50 条
  • [1] INFRARED-SENSOR TRACKS TEMPERATURE
    SCHOENSTEIN, PG
    [J]. INTECH, 1991, 38 (04) : 38 - 39
  • [2] INFRARED, THERMISTOR, AND GLASS-MERCURY THERMOMETER BODY-TEMPERATURE MEASUREMENT IN CHILDREN WITH CANCER
    SHENEP, JL
    ADAIR, JR
    ROBERSON, PK
    HUGHES, WT
    FLYNN, PM
    OAKES, LL
    MARINA, NM
    [J]. PEDIATRIC RESEARCH, 1991, 29 (04) : A151 - A151
  • [3] INFRARED, THERMISTOR, AND GLASS-MERCURY THERMOMETRY FOR MEASUREMENT OF BODY-TEMPERATURE IN CHILDREN WITH CANCER
    SHENEP, JL
    ADAIR, JR
    HUGHES, WT
    ROBERSON, PK
    FLYNN, PM
    BRODKEY, TO
    FULLEN, GH
    KENNEDY, WT
    OAKES, LL
    MARINA, NM
    [J]. CLINICAL PEDIATRICS, 1991, 30 (04) : 36 - 41
  • [4] BODY-TEMPERATURE MEASUREMENT
    TOGAWA, T
    [J]. CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1985, 6 (02): : 83 - 108
  • [5] AN EVALUATION OF BODY-TEMPERATURE MEASUREMENT
    ILSLEY, AH
    RUTTEN, AJ
    RUNCIMAN, WB
    [J]. ANAESTHESIA AND INTENSIVE CARE, 1983, 11 (01) : 31 - 39
  • [6] MODERN METHODS FOR THE MEASUREMENT OF BODY-TEMPERATURE
    ALLAN, JR
    [J]. ANAESTHESIA, 1982, 37 (04) : 507 - 508
  • [7] MEASUREMENT OF BODY-TEMPERATURE IN NEONATAL MICE
    GOODRICH, CA
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1977, 43 (06) : 1102 - 1105
  • [8] EPITAXIALLY GROWN PYROELECTRIC INFRARED-SENSOR ARRAY FOR HUMAN-BODY DETECTION
    CHOI, JR
    LEE, DH
    NAM, HJ
    CHO, SM
    LEE, JH
    KIM, KY
    [J]. INTEGRATED FERROELECTRICS, 1995, 6 (1-4) : 241 - 251
  • [9] INFRARED-SENSOR FOR REMOTE TEMPERATURE MONITORING OF SOLAR THERMAL CENTRAL RECEIVERS
    WARREN, DW
    [J]. PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1983, 366 : 112 - 121
  • [10] An assessment of infrared tympanic thermometers for body temperature measurement
    Betta, V
    Cascetta, F
    Sepe, D
    [J]. PHYSIOLOGICAL MEASUREMENT, 1997, 18 (03) : 215 - 225