PITFALLS ON THE ROAD TO THE IDEAL TIME-OF-FLIGHT MIRROR - IDEAL TIME-FOCUSING IN THE 2ND STAGE OF TANDEM MASS SPECTROMETERS

被引:22
|
作者
MAKAROV, AA
RAPTAKIS, EN
DERRICK, PJ
机构
[1] UNIV WARWICK,INST MASS SPECTROMETRY,COVENTRY CV4 7AL,W MIDLANDS,ENGLAND
[2] UNIV WARWICK,DEPT CHEM,COVENTRY CV4 7AL,W MIDLANDS,ENGLAND
关键词
HIGH-ENERGY COLLISIONS; ION MIRROR; ION OPTICS; TANDEM MASS SPECTROMETER; TIME OF FLIGHT;
D O I
10.1016/0168-1176(95)04210-C
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
The use of time-of-flight (TOF) mass analysers in the second stage of tandem mass spectrometers employing high energy collision-induced fragmentation is considered. The challenge of achieving detection of all fragment ions and unit mass resolution (in the mass range up to, say, 2000 m/z) cannot be successfully met by traditional reflectrons, because of the huge energy spread of the fragment ions. Quadratic-field mirrors providing independence of time of flight from initial energy and angular spreads (i.e. ideal time-focusing) are required. The limits on the mass resolutions of quadratic-field mirrors are shown to be imposed by two types of factors: (i) fundamental limitations, such as uncertainty in the coordinate of ion fragmentation inside the collision cell, metastable decay of ions inside the mirror, and the presence of small field-free and acceleration regions; (ii) imperfections in the field approximation by multi-electrode systems resulting in long-range held sag accompanied by short-range periodic field variations. The greatest challenge in practical applications of quadratic-field mirrors arises from defocusing in the transverse direction, which holds serious implications for the efficiency of transmission. It is shown that appropriate choice of mirror, detector and collision cell dimensions, coupled with correction of electrodes potentials, should be capable of providing better than unit mass-resolution in the mass range up to several thousand m/z. Comparison is made with the orthogonal TOF analysers used for the same purpose. The latter are shown to suffer more stringent limitations on mass resolution at high m/z, compared to quadratic mirrors.
引用
收藏
页码:165 / 182
页数:18
相关论文
共 50 条
  • [1] Ideal velocity focusing in a reflectron time-of-flight mass spectrometer
    Doroshenko, VM
    Cotter, RJ
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (10) : 992 - 999
  • [2] 2 TIME-OF-FLIGHT MASS SPECTROMETERS
    HARRINGTON, DB
    [J]. ANALYTICAL CHEMISTRY, 1957, 29 (09) : 1377 - 1377
  • [3] 2ND-ORDER SPACE FOCUSING IN 2-FIELD TIME-OF-FLIGHT MASS SPECTROMETERS
    ELAND, JHD
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 1993, 4 (12) : 1522 - 1524
  • [4] Ideal space focusing in a time-of-flight mass spectrometer: an optimization using an analytical approach
    Doroshenko, VM
    [J]. EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2000, 6 (06) : 491 - 499
  • [5] High Energy Collisions on Tandem Time-of-Flight Mass Spectrometers
    Cotter, Robert J.
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2013, 24 (05) : 657 - 674
  • [6] NEW METHOD FOR FOCUSING ION BUNCHES IN TIME-OF-FLIGHT MASS SPECTROMETERS
    KARATAEV, VI
    SHMIKK, DV
    MAMYRIN, BA
    [J]. SOVIET PHYSICS TECHNICAL PHYSICS-USSR, 1972, 16 (07): : 1177 - &
  • [7] Theoretical study of space focusing in linear time-of-flight mass spectrometers
    Seccombe, DP
    Reddish, TJ
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (02): : 1330 - 1338
  • [8] Aberrations of the cylindrical mirror time-of-flight mass spectrometers with oblique incidence
    Ioanoviciu, D
    Ioanoviciu, A
    Cuna, S
    Cosma, V
    Szilagyi, E
    Albert, I
    [J]. JOURNAL OF MASS SPECTROMETRY, 2005, 40 (12): : 1626 - 1627
  • [9] Tandem and very high mass time-of-flight mass spectrometers for proteome research
    Cotter, Robert J.
    Iltchenko, Serguei
    Gundry, Rebekah
    [J]. MOLECULAR & CELLULAR PROTEOMICS, 2004, 3 (10) : S124 - S124
  • [10] Design of high performance time-of-flight (TOF) and tandem time-of-flight (TOF-TOF) mass spectrometers.
    Vestal, M