GPU-Based Fourier Domain Optical Coherence Tomography System for Real Time Imaging of Human Skin

被引:0
|
作者
Zhu Shanshan [1 ]
Gao Wanrong [1 ]
Shi Weisong [1 ]
机构
[1] Nanjing Univ Sci & Technol, Sch Elect & Opt Engn, Nanjing 210094, Jiangsu, Peoples R China
关键词
medical optics; medical imaging; graphics processing unit (GPU); parallel computing; spectral-domain optical coherence tomography (SD-OCT); two-dimensional real-time imaging;
D O I
10.3788/LOP55.041701
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The non-damage, high speed, and ultra-high resolution characteristics of optical coherence tomography (OCT) technology in in vivo imaging application make it a broad space for development in the biomedical imaging field. Generally, a large amount of OCT data are acquired , and fast Fourier transform (FFT) in the image reconstruction process requires much calculation time. Therefore, the traditional central processing unit (CPU) serial data processing mode is difficult to meet the requirements of real-time imaging. To this end, the compute unified device architecture (CUDA) parallel programming technique is applied to the data processing of skin tissue imaging in the spectral-domain optical coherence tomography (SD-OCT) system, and it is implemented in the graphics processing unit (GPU). We detail the parallelization of the system algorithm and the parallel processing of the data collected by the system to improve the imaging speed. In the experiment, we use the SD-OCT system to image the skin of the finger and collect the data. The data collected by the laboratory's existing data processing platform MATLAB and GPU are processed respectively, and the imaging speed and image quality of different data processing platforms are compared. The experimental results show that the GPU and CPU hybrid programming model has a processing speed up to 10 times faster than the CPU-based MATLAB method while the image quality remains the same, which meets the clinical requirement of real-time imaging in the clinic.
引用
收藏
页数:8
相关论文
共 19 条
  • [1] Bian HY, 2014, ACTA OPT SINICA, V34, P0211003, DOI 10.3788/AOS201434.0211003
  • [2] CHAI Q, 2016, ACTA OPT SINICA, V36
  • [3] Removing noises caused by motion artefacts in microcirculation maps of human skin in vivo
    Chen, C.
    Shi, W.
    Gao, W.
    [J]. JOURNAL OF MICROSCOPY, 2015, 260 (03) : 389 - 399
  • [4] State-of-the-art retinal optical coherence tomography
    Drexler, Wolfgang
    Fujimoto, James G.
    [J]. PROGRESS IN RETINAL AND EYE RESEARCH, 2008, 27 (01) : 45 - 88
  • [5] Guo Y C, 2017, LASER OPTOELECTRONIC, V54
  • [6] Total retinal blood flow measurement by three beam Doppler optical coherence tomography
    Haindl, Richard
    Trasischker, Wolfgang
    Wartak, Andreas
    Baumann, Bernhard
    Pircher, Michael
    Hitzenberger, Christoph K.
    [J]. BIOMEDICAL OPTICS EXPRESS, 2016, 7 (02): : 287 - 301
  • [7] OPTICAL COHERENCE TOMOGRAPHY
    HUANG, D
    SWANSON, EA
    LIN, CP
    SCHUMAN, JS
    STINSON, WG
    CHANG, W
    HEE, MR
    FLOTTE, T
    GREGORY, K
    PULIAFITO, CA
    FUJIMOTO, JG
    [J]. SCIENCE, 1991, 254 (5035) : 1178 - 1181
  • [8] High-speed optical coherence tomography signal processing on GPU
    Li, Xiqi
    Shi, Guohua
    Zhang, Yudong
    [J]. 9TH INTERNATIONAL CONFERENCE ON PHOTONICS AND IMAGING IN BIOLOGY AND MEDICINE (PIBM 2010), 2011, 277
  • [9] Liu H, 2016, CHINESE J LASERS, V13
  • [10] Liu Q Y, 2013, CHINESE J MED INSTRU, V37, P1