STABILITY OF FIXATION IN HEALTHY-SUBJECTS DURING AUTOMATED PERIMETRY

被引:0
|
作者
EIZENMAN, M [1 ]
TROPE, GE [1 ]
FORTINSKY, M [1 ]
MURPHY, PH [1 ]
机构
[1] UNIV TORONTO,DEPT OPHTALMOL,TORONTO M5S 1A1,ONTARIO,CANADA
关键词
EYE MOVEMENTS; FIXATION; FIXATION LOSS; FIXATION STABILITY; PERIMETRY; SHORT-TERM FLUCTUATION;
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The stability of fixation of 12 healthy young subjects was assessed with a high-resolution eye tracker during automated perimetry. All the subjects exhibited eye movements and fixation shifts during the examination. The average shift in eye position between successive 1-minute intervals ranged from 0.41-degrees to 2.11-degrees, and the average standard deviation of eye position around the average of each interval ranged from 0.56-degrees to 2.55-degrees. In nine of the subjects the eye remained within 3-degrees of centre for 96% or more of the stimuli. The remaining three subjects experienced difficulty maintaining central fixation: the eye was more than 3-degrees away from centre for 28% or more of the stimuli. In the latter subjects the ability to repeatedly stimulate the intended retinal test locations was substantially reduced. The authors discuss the effects of unstable fixation on short-term fluctuation and on fixation loss.
引用
收藏
页码:336 / 340
页数:5
相关论文
共 50 条
  • [1] STABILITY OF SERUM FERRITIN IN HEALTHY-SUBJECTS
    ULVIK, RJ
    [J]. HAEMATOLOGIA, 1984, 17 (04) : 433 - 438
  • [2] Ocular stability during static and kinetic fixation perimetry
    Flanagan, JG
    Rhemtulla, EK
    Eizenman, M
    Asman, P
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S845 - S845
  • [3] Standard Automated Perimetry versus Matrix Frequency Doubling Technology Perimetry in Subjects with Ocular Hypertension and Healthy Control Subjects
    Lamparter, Julia
    Aliyeva, Shakhsanam
    Schulze, Andreas
    Berres, Manfred
    Pfeiffer, Norbert
    Hoffmann, Esther M.
    [J]. PLOS ONE, 2013, 8 (02):
  • [4] A Comparison of Learning Effects for Standard Automated Perimetry, Short-wavelength Automated Perimetry and Frequency-Doubling Technology Perimetry in Healthy Subjects
    Myers, Lorraine
    Hu, Rongrong
    Morgan, Linda S.
    Hoop, Joni S.
    Racette, Lyne
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [5] Variability in monocular and binocular fixation during standard automated perimetry
    Hirasawa, Kazunori
    Kobayashi, Kaoru
    Shibamoto, Asuka
    Tobari, Houmi
    Fukuda, Yuki
    Shoji, Nobuyuki
    [J]. PLOS ONE, 2018, 13 (11):
  • [6] Automated perimetry and threats to fixation - reply
    Drance, SM
    [J]. OPHTHALMOLOGY, 1998, 105 (09) : 1575 - 1575
  • [7] Automated perimetry in detecting threats to fixation
    Zhang, LL
    Drance, SM
    Douglas, GR
    [J]. OPHTHALMOLOGY, 1997, 104 (11) : 1918 - 1920
  • [8] DIAPHRAGMATIC FUNCTION IN HEALTHY-SUBJECTS DURING PARTIAL CURARIZATION
    GAL, TJ
    GOLDBERG, SK
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1980, 48 (06) : 921 - 926
  • [9] AUTOMATED MEASUREMENT OF IMMEDIATE MEMORY PARAMETER IN HEALTHY-SUBJECTS OVER 65
    DERIVERA, JLG
    CONCEPCION, A
    MONTERREY, A
    RODRIGUEZPULIDO, F
    [J]. ARCHIVOS DE NEUROBIOLOGIA, 1993, 56 (05): : 245 - 254
  • [10] BLOOD OF HEALTHY-SUBJECTS AND AGING
    PIMENOV, YS
    [J]. GEMATOLOGIYA I TRANSFUZIOLOGIYA, 1993, 38 (03): : 43 - 45