A new grid stimulus with subtle flicker perception for user-friendly SSVEP-based BCIs

被引:7
|
作者
Ming, Gege [1 ,2 ]
Zhong, Hui [3 ]
Pei, Weihua [1 ,2 ]
Gao, Xiaorong [4 ]
Wang, Yijun [1 ,2 ,5 ]
机构
[1] Chinese Acad Sci, Inst Semicond, State Key Lab Integrated Optoelect, Beijing 100083, Peoples R China
[2] Univ Chinese Acad Sci, Sch Future Technol, Beijing 100049, Peoples R China
[3] Jiangsu JITRI Brian Machine Fus Intelligence Inst, Suzhou 215008, Peoples R China
[4] Tsinghua Univ, Dept Biomed Engn, Beijing 100084, Peoples R China
[5] Chinese Inst Brain Res, Beijing 102206, Peoples R China
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
brain-computer interfaces; electroencephalography; grid stimulus; steady-state visual evoked potentials; task-related component analysis; VISUAL-CORTEX; RESPONSES; ILLUMINATION; PERFORMANCE; FREQUENCY; HUMANS; EYE;
D O I
10.1088/1741-2552/acbee0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. The traditional uniform flickering stimulation pattern shows strong steady-state visual evoked potential (SSVEP) responses and poor user experience with intense flicker perception. To achieve a balance between performance and comfort in SSVEP-based brain-computer interface (BCI) systems, this study proposed a new grid stimulation pattern with reduced stimulation area and low spatial contrast. Approach. A spatial contrast scanning experiment was conducted first to clarify the relationship between the SSVEP characteristics and the signs and values of spatial contrast. Four stimulation patterns were involved in the experiment: the ON and OFF grid stimulation patterns that separately activated the positive or negative contrast information processing pathways, the ON-OFF grid stimulation pattern that simultaneously activated both pathways, and the uniform flickering stimulation pattern that served as a control group. The contrast-intensity and contrast-user experience curves were obtained for each stimulation pattern. Accordingly, the optimized stimulation schemes with low spatial contrast (the ON-50% grid stimulus, the OFF-50% grid stimulus, and the Flicker-30% stimulus) were applied in a 12-target and a 40-target BCI speller and compared with the traditional uniform flickering stimulus (the Flicker-500% stimulus) in the evaluation of BCI performance and subjective experience. Main results. The OFF-50% grid stimulus showed comparable online performance (12-target, 2 s: 69.87 +/- 0.74 vs. 69.76 +/- 0.58 bits min(-1), 40-target, 4 s: 57.02 +/- 2.53 vs. 60.79 +/- 1.08 bits min(-1)) and improved user experience (better comfortable level, weaker flicker perception and higher preference level) compared to the traditional Flicker-500% stimulus in both multi-targets BCI spellers. Significance. Selective activation of the negative contrast information processing pathway using the new OFF-50% grid stimulus evoked robust SSVEP responses. On this basis, high-performance and user-friendly SSVEP-based BCIs have been developed and implemented, which has important theoretical significance and application value in promoting the development of the visual BCI technology.
引用
收藏
页数:22
相关论文
共 28 条
  • [1] Optimizing Visual Stimulation Paradigms for User-Friendly SSVEP-Based BCIs
    Gu, Meng
    Pei, Weihua
    Gao, Xiaorong
    Wang, Yijun
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2024, 32 : 1090 - 1099
  • [2] Optimizing spatial properties of a new checkerboard-like visual stimulus for user-friendly SSVEP-based BCIs
    Ming, Gege
    Pei, Weihua
    Chen, Hongda
    Gao, Xiaorong
    Wang, Yijun
    JOURNAL OF NEURAL ENGINEERING, 2021, 18 (05)
  • [3] A large database towards user-friendly SSVEP-based BCI
    Yue Dong
    Sen Tian
    Brain Science Advances, 2023, 9 (04) : 297 - 309
  • [4] A User-Friendly Dictionary-Supported SSVEP-based BCI Application
    Stawicki, Piotr
    Gembler, Felix
    Volosyak, Ivan
    SYMBIOTIC INTERACTION (SYMBIOTIC 2016), 2017, 9961 : 168 - 180
  • [5] Stimulus-Stimulus Transfer Based on Time-Frequency-Joint Representation in SSVEP-Based BCIs
    Wang, Ze
    Wong, Chi Man
    Rosa, Agostinho
    Qian, Tao
    Jung, Tzyy-Ping
    Wan, Feng
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2023, 70 (02) : 603 - 615
  • [6] User discomfort in SSVEP-based BCIs - can modulation depth offer a solution?
    Gilford, Cheryl
    Camilleri, Tracey
    Camilleri, Kenneth P.
    BRAIN-COMPUTER INTERFACES, 2024, : 159 - 177
  • [7] A user-friendly SSVEP-based brain-computer interface using a time-domain classifier
    Luo, An
    Sullivan, Thomas J.
    JOURNAL OF NEURAL ENGINEERING, 2010, 7 (02)
  • [8] Transferring Subject-Specific Knowledge Across Stimulus Frequencies in SSVEP-Based BCIs
    Wong, Chi Man
    Wang, Ze
    Rosa, Agostinho C.
    Chen, C. L. Philip
    Jung, Tzyy-Ping
    Hu, Yong
    Wan, Feng
    IEEE TRANSACTIONS ON AUTOMATION SCIENCE AND ENGINEERING, 2021, 18 (02) : 552 - 563
  • [9] Spatial Filtering in SSVEP-Based BCIs: Unified Framework and New Improvements
    Wong, Chi Man
    Wang, Boyu
    Wang, Ze
    Lao, Ka Fai
    Rosa, Agostinho
    Wan, Feng
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2020, 67 (11) : 3057 - 3072
  • [10] A User-Friendly SSVEP-Based BCI Using Imperceptible Phase-Coded Flickers at 60Hz
    Lu Jiang
    Weihua Pei
    Yijun Wang
    China Communications, 2022, 19 (02) : 1 - 14