DECREASE IN THE SINGLE-BREATH DIFFUSING-CAPACITY AFTER SATURATION DIVES

被引:0
|
作者
SUZUKI, S
IKEDA, T
HASHIMOTO, A
机构
来源
UNDERSEA BIOMEDICAL RESEARCH | 1991年 / 18卷 / 02期
关键词
OXYGEN TOXICITY; PULMONARY FUNCTION; PROLONGED OXYGEN BREATHING; SATURATION DIVE;
D O I
暂无
中图分类号
P7 [海洋学];
学科分类号
0707 ;
摘要
Before and after saturation dives, we measured lung volumes and diffusing capacity (DLCO/VA) with a single-breath method on 12 divers (6 divers per dive) who participated in 300-msw saturation dives (total dive time of 15 days with PO2 = 0.42 atm abs) and on 6 divers who were engaged in a 320-msw saturation dive (6 days of bottom time with PO2 = 0.42 atm abs and 12 days of total decompression time with PO2 = 0.495 atm abs. In all divers, vital capacity right after surfacing did not significantly decrease compared with predive values. In the 300-msw saturation divers after surfacing, DLCO/VA adjusted for hemoglobin (Hb) changes did not significantly decrease, but in the 320-msw saturation divers Hb-adjusted DLCO/VA was significantly (P < 0.001) decreased by 0.70 (mean) +/- 0.21 (SD) (ml.min-1.mmHg-1.liter-1). These observations indicate that the diffusing capacity is a more sensitive index of pulmonary oxygen toxicity than vital capacity that is traditionally used, and that oxygen partial pressure less than 0.5 atm abs can induce a decrease in pulmonary function.
引用
收藏
页码:103 / 109
页数:7
相关论文
共 50 条
  • [1] REFERENCE EQUATIONS FOR THE SINGLE-BREATH DIFFUSING-CAPACITY
    MILLER, A
    THORNTON, JC
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1986, 133 (06): : 1210 - 1210
  • [2] REFERENCE EQUATIONS FOR THE SINGLE-BREATH DIFFUSING-CAPACITY - REPLY
    PAOLETTI, P
    VIEGI, G
    PISTELLI, G
    DIPEDE, F
    GIUNTINI, C
    LEBOWITZ, MD
    KNUDSON, RJ
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1986, 133 (06): : 1211 - 1211
  • [3] AUTOMATIC DEVICE FOR SINGLE-BREATH CO DIFFUSING-CAPACITY IN DOGS
    DERKS, CM
    LISART, J
    ENGLERT, M
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1977, 368 (1-2): : 135 - 140
  • [4] IMPROVED ACCURACY AND PRECISION OF SINGLE-BREATH CO DIFFUSING-CAPACITY MEASUREMENTS
    GRAHAM, BL
    MINK, JT
    COTTON, DJ
    JOURNAL OF APPLIED PHYSIOLOGY, 1981, 51 (05) : 1306 - 1313
  • [5] ISOLATED REDUCTION IN SINGLE-BREATH DIFFUSING-CAPACITY IN THE EVALUATION OF EXERTIONAL DYSPNEA
    MOHSENIFAR, Z
    COLLIER, J
    BELMAN, MJ
    KOERNER, SK
    CHEST, 1992, 101 (04) : 965 - 969
  • [6] SINGLE-BREATH DIFFUSING-CAPACITY FOR CARBON-MONOXIDE IN STABLE ASTHMA
    COLLARD, P
    NJINOU, B
    NEJADNIK, B
    KEYEUX, A
    FRANS, A
    CHEST, 1994, 105 (05) : 1426 - 1429
  • [7] COMPARISON OF 4 METHODS FOR CALCULATING DIFFUSING-CAPACITY BY THE SINGLE-BREATH METHOD
    BECK, KC
    OFFORD, KP
    SCANLON, PD
    CHEST, 1994, 105 (02) : 594 - 600
  • [8] EVALUATION OF THE SINGLE-BREATH DIFFUSING-CAPACITY IN ASTHMA AND CYSTIC-FIBROSIS
    KEENS, TG
    MANSELL, A
    KRASTINS, IRB
    LEVISON, H
    BRYAN, AC
    HYLAND, RH
    ZAMEL, N
    CHEST, 1979, 76 (01) : 41 - 44
  • [9] STANDARDIZATION OF COMPUTATION OF SINGLE-BREATH DIFFUSING-CAPACITY (TRANSFER-FACTOR)
    MORRIS, AH
    CRAPO, RO
    CLINICAL RESEARCH, 1985, 33 (01): : A80 - A80
  • [10] SINGLE-BREATH DIFFUSING-CAPACITY AND LUNG-VOLUMES IN SMALL LABORATORY MAMMALS
    TAKEZAWA, J
    MILLER, FJ
    ONEIL, JJ
    JOURNAL OF APPLIED PHYSIOLOGY, 1980, 48 (06) : 1052 - 1059