EFFECT OF UNDER-FLOOR WATER STORAGE ON THE THERMAL PERFORMANCE OF A ROOM

被引:2
|
作者
SODHA, MS
KAUR, J
SAWHNEY, RL
机构
[1] Centre of Energy Studies and Research, Devi Ahilya Vishwavidhyalaya, Indore, 452 001, R N Tagore Marg
关键词
UNDERGROUND STORAGE SYSTEMS; WATER STORAGE; DISCOMFORT INDEX;
D O I
10.1002/er.4440160406
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The thermal performance of a room coupled to an evaporatively cooled water storage tank below its floor has been evaluated in terms of the discomfort index for the hot-dry climate of Jodhpur. For a given depth of the storage tank, the effect on the room air temperature of the flow rate with which water is cooled evaporatively has been analysed. It is seen that the storage coupling reduces the mean room temperature but does not affect the swing in the room temperature.
引用
收藏
页码:315 / 326
页数:12
相关论文
共 50 条
  • [1] Simulation of thermal performance of under-floor electric heating system with latent heat thermal energy storage plate
    Lin, Kunping
    Zhang, Yinping
    [J]. Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2003, 24 (05): : 633 - 637
  • [2] Particle dispersion in a room with under-floor air distribution
    Zhang, Z
    Chen, Q
    [J]. INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 2723 - 2728
  • [3] Simulation of helicopter under-floor structure impact on water
    Vignjevic, R
    Meo, M
    [J]. INTERNATIONAL JOURNAL OF CRASHWORTHINESS, 2001, 6 (03) : 425 - 443
  • [4] Effect of thermal conductivities of shape stabilized PCM on under-floor heating system
    Cheng, Wenlong
    Xie, Biao
    Zhang, Rongming
    Xu, Zhiming
    Xia, Yuting
    [J]. APPLIED ENERGY, 2015, 144 : 10 - 18
  • [5] Modeling and simulation of thermal performance of under-floor electric heating system with shape-stabilized PCM thermal energy storage plate
    Lin, KP
    Zhang, YP
    [J]. ENERGY AND ENVIRONMENT, VOLS 1 AND 2, 2003, : 1069 - 1074
  • [6] Effect of raised floor height on different arrangement of under-floor air distribution performance in data center
    Zhang, Meng
    Zhang, Zhongbin
    Hu, Yu
    Geng, Yun
    Huang, Hu
    Huang, Yi
    [J]. 10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 556 - 564
  • [7] THERMAL COMFORT AND IEQ ASSESSMENT OF AN UNDER-FLOOR AIR DISTRIBUTION SYSTEM
    Ioan, Bode Florin
    Verona, Croitoru Cristiana
    Madalin, Dogeanu Angel
    Ilinca, Nastase
    [J]. BUILDING SIMULATION 2013: 13TH INTERNATIONAL CONFERENCE OF THE INTERNATIONAL BUILDING PERFORMANCE SIMULATION ASSOCIATION, 2013, : 2334 - 2339
  • [8] Investigating thermal performance and energy efficiency in under-floor air distribution data centers: A case study
    Feng, Xiumin
    Zhang, Zhongbin
    Zhang, Yu
    Zhang, Yuxuan
    Yao, Yuan
    Wang, Xiaolin
    [J]. THERMAL SCIENCE AND ENGINEERING PROGRESS, 2024, 54
  • [9] Analysis of the Under-Floor Air Supply System
    He, Chengfu
    Zhao, Jingye
    [J]. 6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 1272 - 1278
  • [10] THE EFFECT OF UNDER-FLOOR OBSTRUCTIONS ON DATA CENTER PERFORATED TILE AIRFLOW
    VanGilder, James W.
    Sheffer, Zachary R.
    Zhang, Xuanhang
    O'Kane, Collyn T.
    [J]. PROCEEDINGS OF THE ASME PACIFIC RIM TECHNICAL CONFERENCE AND EXHIBITION ON PACKAGING AND INTEGRATION OF ELECTRONIC AND PHOTONIC SYSTEMS, MEMS AND NEMS 2011, VOL 2, 2012, : 505 - +