MAGNETIC-RESONANCE VELOCITY MAPPING

被引:22
|
作者
UNDERWOOD, SR
FIRMIN, DN
REES, RSO
LONGMORE, DB
机构
[1] Royal Brompton and National Heart Hospital, London
关键词
D O I
10.1088/0143-0815/11/4A/305
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Magnetic resonance velocity mapping is achieved by encoding velocity at each point in a tomographic imaging plane in the phase of the magnetic resonance signal. Although this can be achieved with almost any imaging sequence, cine gradient echo sequences are particularly suitable because of the high signal from blood and the ability to repeat the sequence rapidly to form a cine image. The technique has been shown to be accurate by in vitro and in vivo validation, with flow measurements in the great vessels having an accuracy of approximately 6%. A potential problem arises from loss of signal from turbulent blood flow, but this can be overcome with the use of even echo rephasing and echo times below 5 ms. Using such sequences, velocities of up to 6 m s-1 have been measured clinically and pressure gradients across valves as great as 16 kPa (120 mmHg) can be computed. Clinical application has centred on the measurement of flow in the pulmonary circulation and in shunts and conduits in patients with congenital heart disease. Other applications include the measurement of valvular regurgitation and stenosis, and flow in coronary artery bypass grafts. Flow in native coronary arteries has been measured but the technique requires further development before such measurements can be considered reliable. Real time imaging using echo planar velocity mapping has been achieved and it is hoped that this will make coronary artery flow measurements more robust.
引用
收藏
页码:37 / 43
页数:7
相关论文
共 50 条
  • [1] CIRCULATION REVISITED BY MAGNETIC-RESONANCE VELOCITY MAPPING
    BOGREN, HG
    BUONOCORE, MH
    LEWIS, WR
    FASEB JOURNAL, 1991, 5 (04): : A775 - A775
  • [2] MAGNETIC-RESONANCE VELOCITY MAPPING IN AORTIC DISSECTION
    BOGREN, HG
    UNDERWOOD, SR
    FIRMIN, DN
    MOHIADDIN, RH
    KLIPSTEIN, RH
    REES, RSO
    LONGMORE, DB
    BRITISH JOURNAL OF RADIOLOGY, 1988, 61 (726): : 456 - 462
  • [3] MAGNETIC-RESONANCE VELOCITY MAPPING OF THE CENTRAL CIRCULATION
    SONDERGAARD, L
    CLINICAL PHYSIOLOGY, 1994, 14 (03): : 323 - 328
  • [4] QUANTIFICATION OF AORTIC REGURGITATION BY MAGNETIC-RESONANCE VELOCITY MAPPING
    SONDERGAARD, L
    LINDVIG, K
    HILDEBRANDT, P
    THOMSEN, C
    STAHLBERG, F
    JOEN, T
    HENRIKSEN, O
    AMERICAN HEART JOURNAL, 1993, 125 (04) : 1081 - 1090
  • [5] MAGNETIC-RESONANCE VELOCITY MAPPING OF NORMAL HUMAN TRANSMITRAL VELOCITY PROFILES
    FUJIMOTO, S
    MOHIADDIN, RH
    PARKER, KH
    GIBSON, DG
    HEART AND VESSELS, 1995, 10 (05) : 236 - 240
  • [6] AORTIC COARCTATION ASSESSED BY MAGNETIC-RESONANCE JET VELOCITY MAPPING
    KILNER, PJ
    FIRMIN, DN
    MANZARA, CC
    MARTINEZ, J
    REES, S
    UNDERWOOD, R
    LONGMORE, DB
    CIRCULATION, 1990, 82 (04) : 63 - 63
  • [7] MAGNETIC-RESONANCE VELOCITY MAPPING - CLINICAL-APPLICATION OF A NEW TECHNIQUE
    UNDERWOOD, SR
    FIRMIN, DN
    KLIPSTEIN, RH
    REES, RSO
    LONGMORE, DB
    BRITISH HEART JOURNAL, 1987, 57 (01): : 74 - 75
  • [8] MAGNETIC-RESONANCE VOLUME FLOW AND JET VELOCITY MAPPING IN AORTIC COARCTATION
    MOHIADDIN, RH
    KILNER, PJ
    REES, S
    LONGMORE, DB
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (05) : 1515 - 1521
  • [9] MAGNETIC-RESONANCE VELOCITY MAPPING - CLINICAL-APPLICATION OF A NEW TECHNIQUE
    UNDERWOOD, SR
    FIRMIN, DN
    KLIPSTEIN, RH
    REES, RSO
    LONGMORE, DB
    BRITISH HEART JOURNAL, 1987, 57 (05): : 404 - 412
  • [10] COMPARISON BETWEEN RETROSPECTIVE GATING AND ECG TRIGGERING IN MAGNETIC-RESONANCE VELOCITY MAPPING
    SONDERGAARD, L
    STAHLBERG, F
    THOMSEN, C
    SPRAGGINS, TA
    GYMOESE, E
    MALMGREN, L
    MULLER, E
    HENRIKSEN, O
    MAGNETIC RESONANCE IMAGING, 1993, 11 (04) : 533 - 537