COMPARATIVE LIMITING FLUX ANALYSIS OF BLACK LIQUOR AND POLYETHYLENE-GLYCOL IN ULTRAFILTRATION

被引:16
|
作者
DASGUPTA, S [1 ]
BHATTACHARYA, PK [1 ]
机构
[1] INDIAN INST TECHNOL,DEPT CHEM ENGN,KANPUR 208016,UTTAR PRADESH,INDIA
关键词
D O I
10.1080/00986449008911446
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Ultrafiltration of black liquor was carried out using an asymmetric membrane and the results were compared with that of polyethylene glycol, a standard macromolecule, in a stirred batch cell. The effects of system parameters, e.g., pressure, concentration and stirrer speed on permeate flux and solute rejection were studied extensively for both the solutes. An osmotic pressure model was used to analyze experimental results. To take into account the phenomena of concentration polarization, an extra resistance term, called the polarization layer resistance (Ro), was incorporated into the model. The polarization layer resistance was found to be a function of now regime and concentration at the membrane. To correlate these, the following two types of relationship were examined and tested with the experimental results. © 1990, Taylor & Francis Group, LLC. All rights reserved.
引用
收藏
页码:193 / 210
页数:18
相关论文
共 50 条
  • [1] ULTRAFILTRATION FLUX AND REJECTION CHARACTERISTICS OF BLACK LIQUOR AND POLYETHYLENE-GLYCOL
    PODDAR, TK
    SINGH, RP
    BHATTACHARYA, PK
    CHEMICAL ENGINEERING COMMUNICATIONS, 1989, 75 : 39 - 56
  • [2] LIMITING FLUX PHENOMENA IN ULTRAFILTRATION OF KRAFT BLACK LIQUOR
    SRIDHAR, S
    BHATTACHARYA, PK
    JOURNAL OF MEMBRANE SCIENCE, 1991, 57 (2-3) : 187 - 206
  • [3] PREDICTION OF LIMITING FLUX IN ULTRAFILTRATION OF KRAFT BLACK LIQUOR
    BHATTACHARJEE, C
    BHATTACHARYA, PK
    JOURNAL OF MEMBRANE SCIENCE, 1992, 72 (02) : 137 - 147
  • [4] FLUX DECLINE ANALYSIS IN ULTRAFILTRATION OF KRAFT BLACK LIQUOR
    BHATTACHARJEE, C
    BHATTACHARYA, PK
    JOURNAL OF MEMBRANE SCIENCE, 1993, 82 (1-2) : 1 - 14
  • [5] Ultrafiltration of Lignin from Black Liquor: Modelling Decline in Flux
    Kekana, P. T.
    Sithole, B. B.
    Ramjugernath, D.
    JOURNAL OF SCIENTIFIC & INDUSTRIAL RESEARCH, 2019, 78 (02): : 91 - 95
  • [6] Flux decline during ultrafiltration of kraft black liquor using different flow modules: a comparative study
    Satyanarayana, SV
    Bhattacharya, PK
    De, S
    SEPARATION AND PURIFICATION TECHNOLOGY, 2000, 20 (2-3) : 155 - 167
  • [7] PRETREATMENT OF SERUM SAMPLES FOR IMMUNONEPHELOMETRIC ANALYSIS BY PRECIPITATION WITH POLYETHYLENE-GLYCOL
    HELLSING, K
    ENSTROM, H
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1977, 37 (06): : 529 - 536
  • [8] PROTEIN PRECIPITATION BY ACETONE FOR THE ANALYSIS OF POLYETHYLENE-GLYCOL IN INTESTINAL PERFUSION FLUID
    BUXTON, TB
    CROCKETT, JK
    MOORE, WL
    MOORE, WL
    RISSING, JP
    GASTROENTEROLOGY, 1979, 76 (04) : 820 - 824
  • [9] PROTEIN PRECIPITATION BY ACETONE AND POLYETHYLENE-GLYCOL (PEG) ANALYSIS IN INTESTINAL PERFUSATES
    RISSING, JP
    BUXTON, TB
    CROCKETT, JK
    TALLEDO, RA
    MOORE, WL
    CLINICAL RESEARCH, 1978, 26 (06): : A761 - A761
  • [10] MECHANISM OF PROTEIN PRECIPITATION BY POLYETHYLENE-GLYCOL - ANALYSIS IN TERMS OF EXCLUDED VOLUME
    ATHA, DH
    INGHAM, KC
    FEDERATION PROCEEDINGS, 1980, 39 (06) : 2210 - 2210