Testing A New Method Of Intensive Measurements To Determine The State Of Anti -Corrosion Coating Of Main Pipelines Western Siberia.

被引:0
|
作者
Pyalchenkov, D. V. [1 ]
Pyalchenkov, V. A. [1 ]
机构
[1] Ind Univ Tyumen, Tyumen, Russia
关键词
two-electrode method; corrosion; main pipelines; cathodic protection; Modata;
D O I
暂无
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Integrity of anti-corrosion coating of the main pipeline is a prerequisite for system survival of the entire oil and gas transmission system. Currently, most of the main pipelines of Western Siberia are being operated for 25-35 and more years, and therefore relevance of the problem of controlling their state of isolation is not doubted. Enterprises operating gas and oil pipeline network of great extent, no doubt are interested in qualitative monitoring and adequate interpretation of the results. This paper represents some diagnostic testing results of insulation coating state of main pipelines by a two -electrode intensive measurements method, on the basis of which, recommendations on optimization of this type of work in the conditions of Western Siberia are presented.
引用
收藏
页码:1477 / +
页数:6
相关论文
共 3 条