ACUTE SUBARACHNOID HEMORRHAGE - MR-IMAGING WITH FLUID-ATTENUATED INVERSION-RECOVERY PULSE SEQUENCES

被引:199
|
作者
NOGUCHI, K [1 ]
OGAWA, T [1 ]
INUGAMI, A [1 ]
TOYOSHIMA, H [1 ]
SUGAWARA, S [1 ]
HATAZAWA, J [1 ]
FUJITA, H [1 ]
SHIMOSEGAWA, E [1 ]
KANNO, I [1 ]
OKUDERA, T [1 ]
UEMURA, K [1 ]
YASUI, N [1 ]
机构
[1] RES INST BRAIN & BLOOD VESSELS,DEPT SURG NEUROL,AKITA 010,JAPAN
关键词
ANEURYSM; RUPTURE; ARACHNOID; HEMORRHAGE; BRAIN; MR;
D O I
10.1148/radiology.196.3.7644642
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the usefulness of fluid-attenuated inversion recovery (FLAIR) magnetic resonance (MR) imaging sequences in the detection of acute subarachnoid hemorrhage (SAH). MATERIALS AND METHODS: MR imaging with FLAIR sequences was performed with a 0.5-T superconducting unit in 20 patients (aged 30-72 years) with acute SAH due to a ruptured aneurysm and in 27 control subjects (aged 32-72 years). FLAIR images were obtained 2 hours to 2 days after ictus. Findings were evaluated and compared with computed tomographic (CT) findings. RESULTS: In all patients, acute SAH was clearly demonstrated as an area with signal intensity that was high relative to that of the normal cerebrospinal fluid and surrounding brain parenchyma at FLAIR imaging. This sequence was especially useful in demonstration of acute SAH in the posterior fossa, which was difficult to show at CT because of beam-hardening artifacts. In a double-blind comparison, no FLAIR images acquired in control subjects were confused with those acquired in patients. CONCLUSION: FLAIR sequences reliably provide diagnostic images in patients with acute SAH.
引用
收藏
页码:773 / 777
页数:5
相关论文
共 50 条
  • [1] MR OF ACUTE SUBARACHNOID HEMORRHAGE - A PRELIMINARY-REPORT OF FLUID-ATTENUATED INVERSION-RECOVERY PULSE SEQUENCES
    NOGUCHI, K
    OGAWA, T
    INUGAMI, A
    TOYOSHIMA, H
    OKUDERA, T
    UEMURA, K
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1994, 15 (10) : 1940 - 1943
  • [2] Subacute and chronic subarachnoid hemorrhage: Diagnosis with fluid-attenuated inversion-recovery MR imaging
    Noguchi, K
    Ogawa, T
    Seto, H
    Inugami, A
    Hadeishi, H
    Fujita, H
    Hatazawa, J
    Shimosegawa, E
    Okudera, T
    Uemura, K
    RADIOLOGY, 1997, 203 (01) : 257 - 262
  • [3] Comparison of fluid-attenuated inversion-recovery MR imaging with CT in a simulated model of acute subarachnoid hemorrhage
    Noguchi, K
    Seto, H
    Kamisaki, Y
    Tomizawa, G
    Toyoshima, S
    Watanabe, N
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2000, 21 (05) : 923 - 927
  • [4] Fluid-attenuated inversion-recovery MR imaging in acute and subacute cerebral intraventricular hemorrhage
    Bakshi, R
    Kamran, S
    Kinkel, PR
    Bates, VE
    Mechtler, LL
    Janardhan, V
    Belani, SL
    Kinkel, WR
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1999, 20 (04) : 629 - 636
  • [5] Fluid-attenuated inversion recovery MR Imaging and subarachnoid hemorrhage: Not a panacea
    Mohamed, M
    Heasely, DC
    Yagmurlu, B
    Yousem, DM
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2004, 25 (04) : 545 - 550
  • [6] Fluid-attenuated inversion-recovery MR imaging of gliomatosis cerebri
    Essig, M
    Schlemmer, HP
    Tronnier, V
    Hawighorst, H
    Wirtz, R
    van Kaick, G
    EUROPEAN RADIOLOGY, 2001, 11 (02) : 303 - 308
  • [7] INITIAL CLINICAL-EXPERIENCE IN MR-IMAGING OF THE BRAIN WITH A FAST FLUID-ATTENUATED INVERSION-RECOVERY PULSE SEQUENCE
    RYDBERG, JN
    HAMMOND, CA
    GRIMM, RC
    ERICKSON, BJ
    JACK, CR
    HUSTON, J
    RIEDERER, SJ
    RADIOLOGY, 1994, 193 (01) : 173 - 180
  • [8] Fluid-attenuated inversion-recovery MR imaging of gliomatosis cerebri
    M. Essig
    H.-P. Schlemmer
    V. Tronnier
    H. Hawighorst
    R. Wirtz
    G. van Kaick
    European Radiology, 2001, 11 : 303 - 308
  • [9] USE OF FLUID-ATTENUATED INVERSION-RECOVERY PULSE SEQUENCES FOR IMAGING THE SPINAL-CORD
    WHITE, SJ
    HAJNAL, JV
    YOUNG, IR
    BYDDER, GM
    MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (01) : 153 - 162
  • [10] Fluid-attenuated inversion-recovery SSFP imaging
    Bangerter, Neal K.
    Hargreaves, Brian A.
    Gold, Garry E.
    Stucker, Daniel T.
    Nishimura, Dwight G.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (06) : 1426 - 1431