LIGHT-ELEMENT TRACE ANALYSIS BY MEANS OF TXRF USING SYNCHROTRON-RADIATION

被引:0
|
作者
STRELI, C
机构
来源
关键词
EDXRF; TXRF; SYNCHROTRON RADIATION; LOW-Z ELEMENTS; LIGHT ELEMENTS;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Synchrotron radiation is the ideal excitation source for photon induced X-ray Fluorescence Analysis (XRF) of light elements, e.g. B, C, N, O, F, Na, Mg, Al,.. due to its best suited spectral distribution and spectral brightness. Total Reflection S-ray Fluorescence Analysis (TXRF), a special method of energy dispersive XRF offers some advantages in excitation and detection geometry especially for light element detection. A combination of TXRF with synchrotron radiation leads to drastically reduced detection limits. 200 Mg for Mg have been achieved at SSRL, Stanford, California. The principle, the experimental setup, as well as results are described.
引用
收藏
页码:109 / 117
页数:9
相关论文
共 50 条
  • [1] TRACE-ELEMENT ANALYSIS OF STEEL SAMPLES WITH SYNCHROTRON-RADIATION
    WHEELER, RM
    CHATURVEDI, RP
    DUGGAN, JL
    MARBLE, DK
    BRASWELL, D
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1993, 79 (1-4): : 545 - 548
  • [2] THE USE OF SYNCHROTRON-RADIATION FOR TRACE-ELEMENT ANALYSIS OF BIOMEDICAL SAMPLES
    VALKOVIC, V
    MOSCHINI, G
    [J]. RIVISTA DEL NUOVO CIMENTO, 1993, 16 (10): : 1 - 55
  • [3] TXRF WITH SYNCHROTRON-RADIATION ANALYSIS OF NI ON SI-WAFER SURFACES
    WOBRAUSCHEK, P
    KREGSAMER, P
    LADISICH, W
    STRELI, C
    PAHLKE, S
    FABRY, L
    GARBE, S
    HALLER, M
    KNOCHEL, A
    RADTKE, M
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 363 (03): : 619 - 620
  • [4] Performances of the TXRF beamline for trace element mapping at the European synchrotron radiation facility
    Comin, F
    Barrett, R
    [J]. APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY, 2003, 680 : 431 - 435
  • [5] QUANTITATIVE LIGHT-ELEMENT ANALYSIS USING EDS
    BLOOMFIELD, DJ
    LOVE, G
    SCOTT, VD
    [J]. JOURNAL DE PHYSIQUE, 1984, 45 (NC-2): : 181 - 184
  • [6] LIGHT-SOURCE FOR SYNCHROTRON-RADIATION TOPOGRAPHICAL STUDY AT BEIJING SYNCHROTRON-RADIATION FACILITY (BSRF)
    ZHAO, JY
    YANG, P
    JIANG, JH
    TIAN, YL
    HAN, Y
    WANG, CX
    SHI, CT
    XIAN, DC
    [J]. HIGH ENERGY PHYSICS & NUCLEAR PHYSICS-ENGLISH EDITION, 1992, 16 (03): : 234 - 241
  • [7] XRF ANALYSIS OF VOLCANIC ASH USING SYNCHROTRON-RADIATION
    SANCHEZ, HJ
    BURATTINI, E
    RUBIO, M
    RIVEROS, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1994, 84 (03): : 408 - 410
  • [8] TRACE-ELEMENT DETERMINATION USING SYNCHROTRON RADIATION
    GIAUQUE, RD
    JAKLEVIC, JM
    THOMPSON, AC
    [J]. ANALYTICAL CHEMISTRY, 1986, 58 (04) : 940 - 944
  • [9] Trace element analysis of tissue section by means of synchrotron radiation: the use of GNUPLOT for SRIXE spectra analysis
    Banas, A
    Kwiatek, WM
    Zajac, W
    [J]. JOURNAL OF ALLOYS AND COMPOUNDS, 2001, 328 (1-2) : 135 - 138
  • [10] Trace element analysis by means of synchrotron radiation, XRF, and PIXE: selection of sample preparation procedure
    Kwiatek, WM
    Kubica, B
    Paluszkiewicz, C
    Galka, M
    [J]. JOURNAL OF ALLOYS AND COMPOUNDS, 2001, 328 (1-2) : 283 - 288