SEDIMENTATION METHOD IN CALIBRATING OPTICAL-PARTICLE COUNTERS

被引:3
|
作者
LEHTIMAKI, M [1 ]
KESKINEN, J [1 ]
JANKA, K [1 ]
机构
[1] TAMPERE UNIV,PHYS LAB,SF-33101 TAMPERE,FINLAND
关键词
D O I
10.1080/02786829008959386
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The use of a horizontal elutriator in calibrating optical particle counters according to aerodynamic particle size has been studied. As elutriator a ceramic component with 4800 parallel square channels with dimensions of 0.1 × 0.1 × 15.2 cm has been used. The advantage of the present method is that the particle penetration characteristic of the elutriator can be easily changed simply by varying the flow rate. The elutriator has been used in studying the properties of an optical particle size analyzer (PMS Las-X). The relationship between the equivalent aerodynamic particle size and the corresponding particle size indicated by the analyzer has been determined by using Arizona road dust particles and dioctylphthalate particles. The practical size range of the method is Dp≥ 0.3 μm. © 1990 Elsevier Science Publishing Co., Inc.
引用
收藏
页码:711 / 715
页数:5
相关论文
共 50 条
  • [1] INTERCOMPARISON OF OPTICAL-PARTICLE COUNTERS
    GEBHART, J
    BLANKENBERG, P
    BORMANN, S
    ROTH, C
    [J]. STAUB REINHALTUNG DER LUFT, 1983, 43 (11): : 439 - 447
  • [2] METHODS FOR CALIBRATION OF OPTICAL-PARTICLE COUNTERS
    BIRD, MA
    [J]. 1988 WORKSHOP AND SYMPOSIUM, TECHNICAL PRESENTATIONS : COMPETITIVENESS IN A WORLD MARKET, 1988, : 411 - 423
  • [3] PERFORMANCE AND PROPERTIES OF OPTICAL-PARTICLE COUNTERS
    GEBHART, J
    [J]. TECHNISCHES MESSEN, 1989, 56 (05): : 192 - 203
  • [4] OPTICAL-PARTICLE COUNTERS - OPTIMIZATION OF RESPONSE FUNCTIONS
    MAKYNEN, J
    [J]. JOURNAL OF AEROSOL SCIENCE, 1988, 19 (07) : 957 - 958
  • [5] EXPERIMENTAL RESPONSES OF 2 OPTICAL-PARTICLE COUNTERS
    CHEN, BT
    CHENG, YS
    YEH, HC
    [J]. JOURNAL OF AEROSOL SCIENCE, 1984, 15 (04) : 457 - 464
  • [6] ON THE SIZING ACCURACY OF LASER OPTICAL-PARTICLE COUNTERS
    SZYMANSKI, WW
    LIU, BYH
    [J]. PARTICLE CHARACTERIZATION, 1986, 3 (01): : 1 - 7
  • [7] SIZE RESOLUTION OF LASER OPTICAL-PARTICLE COUNTERS
    VANDERMEULEN, A
    VANELZAKKER, BG
    PLOMP, A
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 1986, 5 (03) : 313 - 324
  • [8] VIRTUAL IMPACTOR AS AN ACCESSORY TO OPTICAL-PARTICLE COUNTERS
    KESKINEN, J
    JANKA, K
    LEHTIMAKI, M
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 1987, 6 (01) : 79 - 83
  • [9] A STUDY OF GEOMETRICAL FACTOR IN OPTICAL-PARTICLE COUNTERS
    SINGH, C
    SINGH, RN
    PILLAI, PKC
    NATH, N
    CHATTOPADHYAYA, SK
    [J]. OPTICA APPLICATA, 1982, 12 (02) : 231 - 242
  • [10] COMPARATIVE-ASSESSMENT OF OPTICAL-PARTICLE COUNTERS
    LEUSCHNER, AH
    KRUGER, L
    [J]. HEALTH PHYSICS, 1979, 36 (04): : 555 - 555