Myocardial perfusion scintigraphy - interpretation of gated imaging. Part 2

被引:5
|
作者
Czaja, Monika Z. [1 ]
Wygoda, Zbigniew [2 ,3 ]
Duszanska, Agata [4 ]
Szczerba, Dominik [5 ]
Glowacki, Jan [6 ]
Gasior, Mariusz [7 ]
Wasilewski, Jaroslaw P. [7 ]
机构
[1] Med Univ Silesia, Sch Med, Dept Cardiol 3, Student Sci Soc,Div Dent Zabrze, Katowice, Poland
[2] Ctr Oncol, Inst Nucl Med & Oncol Endocrinol, Gliwice, Poland
[3] Silesian Ctr Heart Dis, Lab Nucl Med, Zabrze, Poland
[4] Silesian Ctr Heart Dis, Dept Cardiac Surg Transplantol & Mech Circulatory, Zabrze, Poland
[5] Med Univ Silesia, Inst Theoret Phys, Future Proc, Gliwice, Poland
[6] Med Univ Silesia, Lab Imaging Diagnost, Silesian Ctr Heart Dis Zabrze, Sch Med,Div Dent Zabrze,Chair & Inst Med Radiol &, Gliwice, Poland
[7] Med Univ Silesia, Silesian Ctr Heart Dis Zabrze, Dept Cardiol 3, Sch Med,Div Dent Zabrze, Katowice, Poland
来源
关键词
gated single photon emission computed tomography; contractility; thickening; systolic function; diastolic function;
D O I
10.5114/kitp.2018.74676
中图分类号
R61 [外科手术学];
学科分类号
摘要
The first part of the review describes the basic aspects of interpreting myocardial perfusion defects in single photon emission computed tomography (SPECT) scintigraphy. It also presents indications for invasive diagnostics based on stress perfusion defects. This article provides basic information concerning the interpretation of gated SPECT imaging, including such parameters as left ventricular wall motion and thickening as well as left ventricular wall systolic and diastolic function. Gated examination combined with the assessment of myocardial perfusion reduces the rate of false positives results of myocardial perfusion scintigraphy in perfusion tests, additionally providing data on left ventricular systolic and diastolic function.
引用
收藏
页码:49 / 56
页数:8
相关论文
共 50 条
  • [1] Effect of gated SPECT results on accuracy of blinded interpretation of Myoview SPECT myocardial perfusion imaging.
    Jain, D
    Jacobson, AF
    Carretta, RF
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 205P - 205P
  • [2] Clinical reproducibility of post-stress gated myocardial perfusion SPECT imaging.
    Lewin, HC
    Berman, DS
    Hayes, SW
    Friedman, JD
    Germano, G
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 160P - 160P
  • [3] Scatter and attenuation correction changes interpretation of gated myocardial perfusion imaging
    Allan Johansen
    Peter Grupe
    Annegrete Veje
    Poul-Erik Nielsen Braad
    Poul Flemming Høilund-Carlsen
    European Journal of Nuclear Medicine and Molecular Imaging, 2004, 31 : 1152 - 1159
  • [4] Scatter and attenuation correction changes interpretation of gated myocardial perfusion imaging
    Johansen, A
    Grupe, P
    Veje, A
    Braad, PEN
    Hoilund-Carlsen, PF
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 (08) : 1152 - 1159
  • [5] Gated Myocardial Perfusion Imaging
    Mackin, Maria L.
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2020, 48 (02) : 139 - 140
  • [6] A STOCHASTIC INTERPRETATION OF THALLIUM MYOCARDIAL PERFUSION SCINTIGRAPHY
    GORIS, ML
    GORDON, E
    KIM, D
    INVESTIGATIVE RADIOLOGY, 1985, 20 (03) : 253 - 259
  • [7] Myocardial perfusion scintigraphy: interpretation of a normal scan
    Knaapen, P.
    NETHERLANDS HEART JOURNAL, 2014, 22 (04) : 148 - 150
  • [8] Myocardial perfusion scintigraphy: interpretation of a normal scan
    P. Knaapen
    Netherlands Heart Journal, 2014, 22 : 148 - 150
  • [9] Evaluation of cirrhotic cardiomyopathy with gated myocardial perfusion scintigraphy
    Aktas, A.
    Kavak, K.
    Yaman, G.
    Gencoglu, A.
    Muderrisoglu, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S272 - S272
  • [10] Reproducibility of wall motion and thickening using fast gated-SPECT myocardial perfusion imaging.
    Everaert, H
    Vanhove, C
    Franken, PR
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 88P - 88P