How can the orientation of CT scanning undermine the biomechanical performance of the intact mandible? A finite element study

被引:2
|
作者
Marques, H. R. [1 ]
Ramos, A. [1 ]
Mesnard, M. [2 ]
机构
[1] Univ Aveiro, Dept Mech Engn, Biomech Res Grp, P-3810193 Aveiro, Portugal
[2] Univ Bordeaux, I2M, CNRS UMR 5295, Talence, France
关键词
CT scan; image acquisition; mandible behaviour; geometry; strain distribution;
D O I
10.1080/21681163.2013.834270
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The bone structures present a complex geometry with non-homogenous mechanical properties. The geometric construction of these in vivo structures involves the computer tomography (CT scan) acquisition. The objective of this work was to analyse the influence of CT scanning and image acquisition of the geometry of the mandible and how it can undermine its biomechanical behaviour using finite element simulation. Two different orientations of CT scans were considered for the same mandible. For the finite element analysis models, six muscle forces (on each side) and three constraints were considered. The results showed that the orientation of scanning modifies the geometry of the mandible and changes the total volume around 21%. Since different strain distributions at the outer side surface of the mandible were observed. The assign properties according CT scan numbers in some regions charge the local behaviour.
引用
收藏
页码:38 / 45
页数:8
相关论文
共 32 条
  • [1] Biomechanical performance of dental implants inserted in different mandible locations and at different angles: A finite element study
    Thomkova, Barbora
    Marcian, Petr
    Borak, Libor
    Joukal, Marek
    Wolff, Jan
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (01): : 128.e1 - 128.e10
  • [2] Biomechanical influence of plate configurations on mandible subcondylar fracture fixation: a finite element study
    Anoushka Gupta
    Abir Dutta
    Kaushik Dutta
    Kaushik Mukherjee
    Medical & Biological Engineering & Computing, 2023, 61 : 2581 - 2591
  • [3] Biomechanical influence of plate configurations on mandible subcondylar fracture fixation: a finite element study
    Gupta, Anoushka
    Dutta, Abir
    Dutta, Kaushik
    Mukherjee, Kaushik
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2023, 61 (10) : 2581 - 2591
  • [4] Biomechanical and morphological analysis of Pierre Robin sequence mandible: Finite element and morphometric study
    Humphries, Laura S.
    Reid, Russell R.
    Ross, Callum F.
    Taylor, Andrea B.
    Collins, John M.
    Freire, Alexandre R.
    Rossi, Ana Claudia
    Prado, Felippe B.
    ANATOMICAL RECORD-ADVANCES IN INTEGRATIVE ANATOMY AND EVOLUTIONARY BIOLOGY, 2021, 304 (07): : 1375 - 1388
  • [6] Biomechanical effects of different miniplate use on bone and miniplate systems in multiple mandible fracture: A finite element study
    Sulukan, Erdinc
    Gumrukcu, Zeynep
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2024, 55 (12):
  • [7] The biomechanical aspects of reconstruction for segmental defects of the mandible: A finite element study to assess the optimisation of plate and screw factors
    Bujtar, Peter
    Simonovics, Janos
    Varadi, Karoly
    Sandor, George K. B.
    Avery, C. M. E.
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2014, 42 (06) : 855 - 862
  • [8] Biomechanical performance of cranial implants with different thicknesses and material properties: A finite element study
    Marcian, Petr
    Narra, Nathaniel
    Borak, Libor
    Chamrad, Jakub
    Wolff, Jan
    COMPUTERS IN BIOLOGY AND MEDICINE, 2019, 109 : 43 - 52
  • [9] How to Optimize Pedicle Screw Parameters for the Thoracic Spine? A Biomechanical and Finite Element Method Study
    Solitro, Giovanni F.
    Welborn, Michelle C.
    Mehta, Ankit, I
    Amirouche, Farid
    GLOBAL SPINE JOURNAL, 2024, 14 (01) : 187 - 194
  • [10] Effects of Attachment Orientation and Designed Vertical Movement on Molar Distalisation With Clear Aligners: A Biomechanical Finite Element Study
    Li, Jialun
    Yang, Yi
    He, Xian
    Lai, Wenli
    Long, Hu
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2025, 28 (02) : 296 - 303