MRI SIMULATION USING THE K-SPACE FORMALISM

被引:33
|
作者
PETERSSON, JS
CHRISTOFFERSSON, JO
GOLMAN, K
机构
[1] Department of Radiation Physics, Lund University, Malmö General Hospital
[2] Department of Experimental Research, Malmö General Hospital
关键词
MRI; SIMULATION; K-SPACE; FLOW;
D O I
10.1016/0730-725X(93)90475-S
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An MRI simulation method, together with a corresponding computer program, using the k-space formalism has been developed. It uses a FFT algorithm to generate the ideal NMR signal from a user defined object. The k-space trajectory given by a pulse sequence is calculated. And it is used to select elements from the ideal NMR signal. This selection of elements mimic the sampling of the signal in an actual MRI experiment. During the sampling procedure changes in signal amplitude due to relaxation and excitation are introduced as well as signal phase changes due to movement or flow. Artifacts due to stimulated echoes and transversal magnetization that propagate through several repetition periods are also handled. The usefulness of the method is demonstrated by calculations using standard spin-echo sequence as well as modifications introduced in order to generate angiographical images and flow phase images. Further more a fast pulse sequence, echo planar imaging (EPI), is also simulated. The method is faster than previously presented ones. It is capable of generating images (128 x 128 matrix), including more than eight different T1 and T2 combinations, in less than 3 min on a standard 386/387 type IBM compatible PC.
引用
收藏
页码:557 / 568
页数:12
相关论文
共 50 条
  • [1] k-Space Deep Learning for Accelerated MRI
    Han, Yoseob
    Sunwoo, Leonard
    Ye, Jong Chul
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (02) : 377 - 386
  • [2] Estimation of k-Space Trajectories in Spiral MRI
    Tan, Hao
    Meyer, Craig H.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (06) : 1396 - 1404
  • [3] Motion artifact suppression in MRI using k-space overlap processing
    Kadah, Yasser M.
    [J]. PROCEEDINGS OF THE 25TH NATIONAL RADIO SCIENCE CONFERENCE: NRSC 2008, 2008, : U221 - U229
  • [4] Partial K-Space MRI Reconstruction Using a Modified Homodyne Approach
    Abche, Antoine
    Yaacoub, Fadi
    Karam, Elie
    [J]. SPA 2010: SIGNAL PROCESSING ALGORITHMS, ARCHITECTURES, ARRANGEMENTS, AND APPLICATIONS CONFERENCE PROCEEDINGS, 2010, : 56 - 61
  • [5] On optimality of parallel MRI reconstruction in k-space
    Samsonov, Alexey A.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (01) : 156 - 164
  • [6] A SIMPLIFIED PHYSICAL PICTURE OF PHASE CONJUGATION USING K-SPACE FORMALISM AND RAY OPTICS
    GHOSH, PK
    BANERJEE, PP
    [J]. AMERICAN JOURNAL OF PHYSICS, 1993, 61 (03) : 237 - 241
  • [7] A Novel Retrospective 3D K-Space Sorting 4D-MRI Technique Using a Radial K-Space Acquisition MRI Sequence
    Liu, Y.
    Subashi, E.
    Yin, F.
    Cai, J.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3898 - 3898
  • [8] Fast Ultrasound Imaging Simulation in K-space
    Hergum, Torbjorn
    Langeland, Stian
    Remme, Espen W.
    Torp, Hans
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (06) : 1159 - 1167
  • [9] COMPRESSED SENSING MRI USING TOTAL VARIATION REGULARIZATION WITH K-SPACE DECOMPOSITION
    Sun, Liyan
    Huang, Yue
    Cai, Congbo
    Ding, Xinghao
    [J]. 2017 24TH IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2017, : 3061 - 3065
  • [10] An Optimized k-Space Configuration for Parallel MRI Reconstruction
    Pugachevskii, M. A.
    Polyakov, A. G.
    [J]. BIOMEDICAL ENGINEERING-MEDITSINSKAYA TEKNIKA, 2020, 54 (01): : 33 - 36