INDIVIDUAL AND SIMULTANEOUS DETERMINATION OF URIC-ACID AND ASCORBIC-ACID BY FLOW-INJECTION ANALYSIS

被引:20
|
作者
ALMUAIBED, AM [1 ]
TOWNSHEND, A [1 ]
机构
[1] UNIV HULL,SCH MED,HULL HU6 7RX,N HUMBERSIDE,ENGLAND
关键词
D O I
10.1016/0039-9140(92)80126-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Flow injection methods for the individual and simultaneous determination of ascorbic acid and uric acid are proposed. A spectrophotometer and a miniamperometric detector are connected in sequence. The calibration graphs for uric acid obtained by measuring its absorbance at 293 nm and its current at +0.6 V are linear up to at least 80 and 70 mug/ml, respectively, with an rsd (n = 10) of 1% for both methods at mid-range concentrations. The calibration graph for ascorbic acid with amperometric detection is linear up to 80 mg/l. with an rsd (n = 10) of 0.8% at 30 mg/l. The simultaneous determination of uric acid and ascorbic acid is based on measurement of the absorbance of uric acid at 393 nm and amperometric determination of both analytes at +0.6 V. The average relative errors of the analysis of binary mixtures of uric acid and ascorbic acid are 2.2 and 4.2%, respectively.
引用
收藏
页码:1459 / 1462
页数:4