A FIELD-EVALUATION OF THE COULTER STKS

被引:65
|
作者
WARNER, BA
REARDON, DM
机构
[1] Department of Hematology, Addenbrooke's Hospital, Cambridge CB2 2QQ, Hills Road
关键词
D O I
10.1093/ajcp/95.2.207
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
The performance of the Coulter STKS(R) (Coulter, Hialeah, FL) was evaluated in a busy computerized teaching hospital laboratory. The STKS was compared with a Coulter S Plus IV and manually performed 400 white blood-cell differentials. The measured blood-count parameters (i.e., white blood cells [WBCs], red blood cells [RBCs], hemoglobin [Hb], mean corpuscular volume [MCV], and platelets [PLTs]), compared very well between the two aperture impedance-based systems; precision, linearity, and lack of carryover were excellent. The STKS WBC differential (DIFF), derived from a combination of aperture impedance, aperture conductance, and laser light scatter, also was precise; linear and carryover were insignificant. The DIFFs (n = 424) compared well to the manual WBC differentials, with r values of 0.97, 0.97, 0.73, and 0.86 for neutrophils, lymphocytes, monocytes, and eosinophils, respectively. The DIFF and Suspect Flagging system produced 6.2% false negatives and 2.6% false positives when compared with the manual technique. These were further investigated and discussed. STKS DIFFs were stable for 18 to 24 hours in normal samples anticoagulated with K2EDTA and stored at 20-degrees-C prior to analysis. Storage in the same anticoagulant at 4-degrees-C and immediate aspiration preserved the DIFF analysis for considerably longer than 24 hours. These performance characteristics make the STKS a significant advancement in automated hematology.
引用
收藏
页码:207 / 217
页数:11
相关论文
共 50 条
  • [1] EVALUATION AND PERFORMANCE OF THE COULTER STKS
    VERHEUL, FEAM
    SPITTERS, JMC
    BERGMANS, CHF
    [J]. EUROPEAN JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1993, 31 (03): : 179 - 186
  • [2] AN EVALUATION OF LEUKOCYTE ANALYSIS ON THE COULTER STKS
    ROBERTSON, EP
    LAI, HW
    WEI, DCC
    [J]. CLINICAL AND LABORATORY HAEMATOLOGY, 1992, 14 (01): : 53 - 68
  • [3] EVALUATION OF THE COULTER STKS 5-PART DIFFERENTIAL
    CORNBLEET, PJ
    MYRICK, D
    LEVY, R
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1993, 99 (01) : 72 - 81
  • [4] MONOCYTE COUNTS ON THE COULTER STKS
    ROBERTSON, EP
    LAI, HW
    WEI, DCC
    AU, M
    [J]. CLINICAL AND LABORATORY HAEMATOLOGY, 1992, 14 (03): : 269 - 270
  • [5] Evaluation of the HemoCue compared with the Coulter STKS for measurement of neonatal haemoglobin
    Rechner, IJ
    Twigg, A
    Davies, AF
    Imong, S
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2002, 86 (03): : 188 - 189
  • [6] MONOCYTE COUNT IN COULTER STKS AND MAXM
    VINATIER, I
    PICARD, F
    FIALON, P
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1992, 98 (02) : 269 - 270
  • [7] IMPROVEMENT IN DIAGNOSTIC PERFORMANCE OF THE COULTER STKS
    FERNANDEZCASTRO, M
    FERRIZ, C
    MARTIN, P
    JIMENEZ, MC
    [J]. BLOOD, 1994, 84 (10) : A589 - A589
  • [8] Evaluation of the ABX Cobas Vega automated hematology analyzer and comparison with the Coulter STKS
    FerreroVacher, C
    Sudaka, I
    Jambou, D
    Vanhaeke, D
    Fischer, F
    Bayle, J
    [J]. HEMATOLOGY AND CELL THERAPY, 1997, 39 (03): : 149 - 158
  • [9] BASOPHIL COUNTS ON THE COULTER STKS HEMATOLOGY ANALYZER
    MALASPINA, D
    [J]. LABORATORY MEDICINE, 1994, 25 (10) : 677 - 677
  • [10] EVALUATION OF THE ERYTHROCYTE AND PLATELET MORPHOLOGICAL ANALYSIS GIVEN BY THE HEMATOLOGY ANALYZER COULTER STKS
    VINATIER, I
    LORRIAUX, C
    CAPIOD, JC
    FAILLE, N
    DELOBEL, J
    [J]. NOUVELLE REVUE FRANCAISE D HEMATOLOGIE, 1992, 34 (02): : 205 - 210