ULTRASONOGRAPHY DETECTION OF RADIOLUCENT FOREIGN-BODIES IN SOFT-TISSUE COMPARED TO COMPUTED-TOMOGRAPHY SCAN

被引:3
|
作者
ALZAHRANI, S [1 ]
KREMLI, M [1 ]
SAADEDDIN, M [1 ]
IKRAM, A [1 ]
TAKRONI, T [1 ]
ZEIDAN, H [1 ]
机构
[1] KING SAUD UNIV, KING KHALID UNIV HOSP, DIV ORTHOPED 49, RIYADH 11472, SAUDI ARABIA
关键词
D O I
10.5144/0256-4947.1995.110
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Thirty-one patients with suspected radiolucent foreign bodies (wooden splinters) in soft tissues of extremities were investigated by plain radiography, computed tomography (CT) scan and ultrasonography to the area suspected clinically. Ultrasonography detected and localized radiolucent foreign bodies in 18 of the 31 patients, while only 14 were seen on CT scan. Following surgical exploration, the presence of foreign bodies was confirmed in 20 patients; thus, the accuracy of ultrasonography was 90 degrees while that of CT scan was 70 degrees. The size of foreign body, the presence of infection or the delay in diagnosis had no effect on results. Ultrasonography is clearly a reliable method of detecting radiolucent foreign bodies in soft tissues of extremities.