Thermal-hydraulic analysis of SWAMUP facility using ATHLET-SC code

被引:1
|
作者
Wang, Zidi [1 ]
Cao, Zhen [1 ]
Liu, Xiaojing [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Nucl Sci & Engn, 800 Dongchuan Rd, Shanghai 200240, Peoples R China
基金
中国国家自然科学基金;
关键词
SWAMUP facility; trans-critical transient; ATHLET-SC code; pre-test calculation;
D O I
10.3389/fenrg.2015.00011
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
During the loss of coolant accident (LOCA) of supercritical water-cooled reactor (SCWR), the pressure in the reactor system will undergo a rapid decrease from the supercritical pressure to the subcritical condition. This process is called trans-critical transients, which is of crucial importance for the LOCA analysis of SCWR. In order to simulate the trans-critical transient, a number of system codes for SCWR have been developed up to date. However, the validation work for the trans-critical models in these codes is still missing. The test facility Supercritical WAter MUltiPurpose loop (SWAMUP) with 2 x 2 rod bundle in Shanghai Jiao Tong University (SJTU) will be applied to provide test data for code validation. Some pre-test calculations are important and necessary to show the feasibility of the experiment. In this study, trans-critical transient analysis is performed for the SWAMUP facility with the system code ATH LET-SC, which is modified in SJTU, for supercritical water system. This paper presents the system behavior, e.g., system pressure, coolant mass flow, cladding temperature during the depressurization. The effects of some important parameters such as heating power, depressurization rate on the system characteristics are also investigated in this paper. Additionally, some sensitivities study of the code models, e.g., heat transfer coefficient, critical heat flux correlation are analyzed and discussed. The results indicate that the revised system code ATH LET-SC is capable of simulating thermal-hydraulic behavior during the trans-critical transient. According to the results, the cladding temperature during the transient is kept at a low value. However, the pressure difference of the heat exchanger after depressurization could reach 6 MPa, which should be considered in the experiment.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Thermal-hydraulic analysis of SWAMUP test facility
    Wang, Zi-Di
    Cao, Zhen
    Liu, Xiao-Jing
    Cheng, Xu
    [J]. Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2015, 49 (07): : 1191 - 1199
  • [2] Thermal-hydraulic model of the reactor facility with lead coolant in the ATHLET code
    Chudinova, V. A.
    Nikonov, S. P.
    [J]. INTERNATIONAL CONFERENCE FOR YOUNG SCIENTISTS, SPECIALISTS AND POST-GRADUATES ON NUCLEAR REACTOR PHYSICS, 2018, 1133
  • [3] Natural circulation experiments at the ISB-VVER integral test facility and calculations using the thermal-hydraulic code ATHLET
    Krepper, E
    Prasser, HM
    [J]. NUCLEAR TECHNOLOGY, 1999, 128 (01) : 75 - 86
  • [4] Validation of the ATHLET-SC code by trans-critical transient data
    Liu, X.
    Cheng, X.
    [J]. KERNTECHNIK, 2016, 81 (02) : 164 - 166
  • [5] PARAMETER ADAPTATION TECHNIQUES FOR THE BEST-ESTIMATE THERMAL-HYDRAULIC CODE ATHLET
    Kerner, Alexander
    Schaefer, Anselm
    Chen, Kan
    [J]. ICONE 17: PROCEEDINGS OF THE 17TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, VOL 3, 2009, : 585 - 593
  • [6] Heat transfer to water near the critical point: evaluation of the ATHLET thermal-hydraulic system code
    Gschnaidtner, T.
    Rodriganez, L. Aymerich
    Lerchl, G.
    Wieland, C.
    Spliethoff, H.
    [J]. KERNTECHNIK, 2019, 84 (05) : 375 - 389
  • [7] Development of a thermal-hydraulic analysis code for CARR
    Tian, WX
    Qiu, SZ
    Guo, Y
    Su, GH
    Jia, DN
    [J]. ANNALS OF NUCLEAR ENERGY, 2005, 32 (03) : 261 - 279
  • [8] Thermal-hydraulic analysis of the coil test facility for CFETR
    Ren, Yong
    Liu, Xiaogang
    Li, Junjun
    Wang, Zhaoliang
    Qiu, Lilong
    Du, Shijun
    Li, Guoqiang
    Gao, Xiang
    [J]. SPRINGERPLUS, 2016, 5
  • [9] DEVELOPMENT AND APPLICATION OF A UTSG THERMAL-HYDRAULIC ANALYSIS CODE
    Cong, Tenglong
    Tian, Wenxi
    Su, Guanghui
    Qiu, Suizheng
    [J]. PROCEEDINGS OF THE 22ND INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2014, VOL 4, 2014,
  • [10] UKAP - A CODE FOR THERMAL-HYDRAULIC ANALYSIS OF A REACTOR CORE
    HUHN, J
    [J]. KERNENERGIE, 1989, 32 (05): : 193 - 198