THE SENSITIVITY OF DROSOPHILA LARVAE TO CONTINUOUS-WAVE ULTRASOUND

被引:3
|
作者
CHILD, SZ [1 ]
RAEMAN, CH [1 ]
WALTERS, E [1 ]
CARSTENSEN, EL [1 ]
机构
[1] UNIV ROCHESTER,ROCHESTER CTR BIOMED ULTRASOUND,ROCHESTER,NY 14627
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 1992年 / 18卷 / 08期
关键词
CW ULTRASOUND; LARVAE; GAS BODY ACTIVATION; CAVITATION;
D O I
10.1016/0301-5629(92)90123-R
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The threshold for killing of freshly hatched Drosophila larvae exposed to continuous-wave (CW) ultrasound shows a minimum at approximately 0.3 MHz. This suggests that the stiffness of the material surrounding the gas bodies in the organism is comparable to water. From this, it is apparent that the gas bodies in three-day-old larvae that we have used in earlier studies are far larger than resonance size at the frequencies (1-5 MHz) used. Yet, these larvae were killed by short exposures to low-temporal-average-intensity pulsed ultrasound with peak intensities of the order of 10 W/cm2. Hence, it appears that "large" bubbles cannot be ignored in considerations of the biological effects of pulsed ultrasound and lithotripsy.
引用
收藏
页码:725 / 728
页数:4
相关论文
共 50 条
  • [1] OCULAR DIMENSIONS BY CONTINUOUS-WAVE ULTRASOUND
    SCHLEGEL, WA
    LAWRENCE, C
    [J]. INVESTIGATIVE OPHTHALMOLOGY, 1969, 8 (02): : 234 - &
  • [2] CONTINUOUS-WAVE ULTRASOUND AND NEOPLASTIC TRANSFORMATION INVITRO
    HARRISON, GH
    BALCERKUBICZEK, EK
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1989, 15 (04): : 335 - 340
  • [3] Generation of ultrasound in materials using continuous-wave lasers
    Caron, James N.
    DiComo, Gregory P.
    Nikitin, Sergei
    [J]. OPTICS LETTERS, 2012, 37 (05) : 830 - 832
  • [4] A full-wave Helmholtz model for continuous-wave ultrasound transmission
    Huttunen, T
    Malinen, M
    Kaipio, JP
    White, PJ
    Hynynen, K
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2005, 52 (03) : 397 - 409
  • [5] ENCAPSULATION OF CONCENTRATED PROTEIN INTO ERYTHROCYTE PORATED BY CONTINUOUS-WAVE ULTRASOUND
    Yamagata, Koutarou
    Kawasaki, Emi
    Kawarai, Hideki
    Iino, Masaaki
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (12): : 1924 - 1933
  • [6] Continuous-wave ultrasound reflectometry for surface roughness imaging applications
    Mitri, F. G.
    Kinnick, R. R.
    Greenleaf, J. F.
    Fatemi, M.
    [J]. ULTRASONICS, 2009, 49 (01) : 10 - 14
  • [7] A continuous-wave ultrasound system for displacement amplitude and phase measurement
    Finneran, JJ
    Hastings, MC
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2004, 115 (06): : 3202 - 3209
  • [8] Modeling of anomalies due to hydrophones in continuous-wave ultrasound fields
    Huttunen, T
    Kaipio, JP
    Hynynen, K
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2003, 50 (11) : 1486 - 1500
  • [9] Continuous-Wave EPR
    van der Est, Art
    [J]. EMAGRES, 2016, 5 (03): : 1411 - 1421
  • [10] MODEL OF DAMAGE DUE TO CONTINUOUS-WAVE HIGH-POWER ULTRASOUND
    HSU, WL
    LELE, PP
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1974, 55 : S6 - S6