TOLUENE POLYMER AS A NEW STATIONARY PHASE IN REVERSED-PHASE COLUMN LIQUID-CHROMATOGRAPHY

被引:8
|
作者
NASUTO, R
KWIETNIEWSKI, L
机构
[1] Department of Physical Chemistry, Faculty of Chemistry, Maria Curie-Skłodowska University, Lublin
关键词
Aromatic hydrocarbons; Column liquid chromatography; Phenols; Silica gel covered with toluene polymer;
D O I
10.1007/BF02261230
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The toluene polymer adhesively sprayed on the surface of silica gel (TP Si100) was used as the packing in reversed-phase liquid column chromatography. The effect of the thickness of the polymer layer covering the silica gel surface on the retention of aromatic hydrocarbons was determined. Retention of aromatic hydrocarbons and phenol on the column packed with TP Si100 is shorter than on a column packed with ODS Si100. Selectivity of the column packed with TP Si100 for phenol, toluene and naphthalene vs. benzene is higher than of a column packed with ODS Si100. Columns packed with TP Si100 were used for the separation of condensed-rings aromatic hydrocarbons and phenols. © 1990 Friedr. Vieweg & Sohn Verlagsgesellschaft mbH.
引用
收藏
页码:597 / 602
页数:6
相关论文
共 50 条
  • [1] STATIONARY PHASE EFFECTS IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY
    COLIN, H
    KRSTULOVIC, A
    GUIOCHON, G
    YUN, Z
    JOURNAL OF CHROMATOGRAPHY, 1983, 255 (JAN): : 295 - 309
  • [2] COLUMN SELECTIVITY IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY
    SANDER, LC
    WISE, SA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1990, 199 : 122 - ANYL
  • [3] STATIONARY-PHASE EFFECTS IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY
    TANAKA, N
    KIMATA, K
    HOSOYA, K
    MIYANISHI, H
    ARAKI, T
    JOURNAL OF CHROMATOGRAPHY A, 1993, 656 (1-2) : 265 - 287
  • [4] PREPARATION AND COMPARISON OF A PENTAFLUOROPHENYL STATIONARY PHASE FOR REVERSED-PHASE LIQUID-CHROMATOGRAPHY
    CSATO, E
    FULOP, N
    SZABO, G
    JOURNAL OF CHROMATOGRAPHY, 1990, 511 : 79 - 88
  • [5] INFLUENCE OF TEMPERATURE ON COLUMN EFFICIENCY IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY
    WARREN, FV
    BIDLINGMEYER, BA
    ANALYTICAL CHEMISTRY, 1988, 60 (24) : 2821 - 2824
  • [6] STATIONARY PHASE EFFECTS IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY UNDER OVERLOAD CONDITIONS
    MILLER, NT
    JOURNAL OF CHROMATOGRAPHY, 1991, 550 (1-2): : 301 - 312
  • [7] ELECTRONIC SPECTROSCOPIC INVESTIGATIONS OF THE STATIONARY-PHASE IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY
    RUTAN, SC
    HARRIS, JM
    JOURNAL OF CHROMATOGRAPHY A, 1993, 656 (1-2) : 197 - 215
  • [8] RETENTION OF RETINOIDS ON AN AROMATIC STATIONARY-PHASE IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY
    SALO, M
    HERRALA, S
    CHROMATOGRAPHIA, 1993, 37 (9-10) : 501 - 504
  • [9] SWOLLEN POLYSILOXANES AS STATIONARY PHASES IN REVERSED-PHASE OPEN-TUBULAR COLUMN LIQUID-CHROMATOGRAPHY
    FOLESTAD, S
    LARSSON, M
    JOURNAL OF CHROMATOGRAPHY, 1987, 394 (03): : 455 - 464
  • [10] SELECTIVITY IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY
    PETROVIC, SM
    LOMIC, S
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1989, 12 (1-2): : 59 - 75