Experimental Investigation with Cross Fluted Double-Pipe Suction Line Heat Exchanger to Enhance AC System Performance

被引:0
|
作者
Mathur, Gursaran D. [1 ]
机构
[1] CalsonicKansei N Amer, 27000 Hills Tech Court, Farmington Hills, MI 48331 USA
关键词
D O I
10.4271/2009-01-0970
中图分类号
U [交通运输];
学科分类号
08 ; 0823 ;
摘要
An experimental investigation has been carried out to quantify the performance enhancements with a suction line heat exchanger (SLHX) in an AC system. An off-the shelf double pipe cross fluted SLHX is used for this investigation. System level bench tests are conducted with an AC system from a 2008 MY mid-sized sedan. The cabin interior condition is held constant at 25 degrees C and 50% RH. The dry bulb temperature for the engine compartment is varied from 25 to 45 degrees C. The compressor speed is varied from 800 to 3000 rpm and the air velocity over the condenser is varied from 2 to 10 m/s. Based on the tests conducted on the AC system without and with SLHX, system performance (COP) has been improved by 7%. Additional tests have been planned with modified SLHX.
引用
收藏
页码:1031 / 1041
页数:11
相关论文
共 50 条
  • [1] Experimental Investigation of Heat Transfer Performance of Molten Salt in Double-pipe Heat Exchanger
    Dong, Xinyu
    Bi, Qincheng
    Jiang, Mengyu
    [J]. Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2021, 41 (19): : 6670 - 6678
  • [2] Experimental investigation on the hydrothermal performance of a double-pipe heat exchanger using helical tape insert
    Salem, M. R.
    Eltoukhey, M. B.
    Ali, R. K.
    Elshazly, K. M.
    [J]. INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2018, 124 : 496 - 507
  • [3] Experimental studies of a double-pipe helical heat exchanger
    Rennie, TJ
    Raghavan, VGS
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2005, 29 (08) : 919 - 924
  • [4] What dominates heat transfer performance of a double-pipe heat exchanger
    Zheng, Dan
    Hu, Zhenwei
    Tian, Liting
    Wang, Jin
    Sunden, Bengt
    [J]. OPEN PHYSICS, 2021, 19 (01): : 863 - 866
  • [5] EFFECTS OF BUOYANCY ON THE PERFORMANCE OF A VERTICAL DOUBLE-PIPE HEAT EXCHANGER
    Voicu, Ionut
    Galanis, Nicolas
    Mare, Thierry
    [J]. COMPUTATIONAL THERMAL SCIENCES, 2011, 3 (05): : 345 - 357
  • [6] Performance of double-pipe heat exchanger enhanced by helical fins
    [J]. Wang, D. (wangdb@zzu.edu.cn), 1600, Materials China (65):
  • [7] Experimental studies of heat transfer of air in a double-pipe helical heat exchanger
    Majidi, Davood
    Alighardashi, Hashem
    Farhadi, Fatola
    [J]. APPLIED THERMAL ENGINEERING, 2018, 133 : 276 - 282
  • [8] Numerical investigation of thermohydraulic performance of air to water double-pipe heat exchanger with helical fins
    El Maakoul, Anas
    El Metoui, Mustapha
    Ben Abdellah, Abdellatif
    Saadeddine, Said
    Meziane, Mohamed
    [J]. APPLIED THERMAL ENGINEERING, 2017, 127 : 127 - 139
  • [9] Thermal analysis of double-pipe heat exchanger in thermodynamic vent system
    Liu, Zhan
    Li, Yanzhong
    Zhou, Ke
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2016, 126 : 837 - 849
  • [10] Investigation of turbulent flow and heat transfer in an air to water double-pipe heat exchanger
    Mohsen Sheikholeslami
    M. Jafaryar
    F. Farkhadnia
    Mofid Gorji-Bandpy
    Davood Domiri Ganji