Left-ventricular unloading with a new pulsatile assist device: The HIA-VAD system and its influence on myocardial stunning

被引:5
|
作者
Waldenberger, FR
Pongo, E
Meyns, B
Flameng, W
机构
[1] KATHOLIEKE UNIV LEUVEN,CTR EXPTL SURG & ANESTHESIOL,PROVISORIUM 1,B-3000 LOUVAIN,BELGIUM
[2] KATHOLIEKE UNIV LEUVEN,DEPT CARDIAC SURG,B-3001 LOUVAIN,BELGIUM
来源
THORACIC AND CARDIOVASCULAR SURGEON | 1995年 / 43卷 / 06期
关键词
cardiac assist device; mechanical unloading; myocardial stunning; HIA-VAD;
D O I
10.1055/s-2007-1013802
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To assess the mechanical unloading properties of a new pneumatic cardiac assist device (60 ml Medos(R) HIA-VAD(R)) and its possible influence on recovery from myocardial stunning we performed a study in 12 anaesthetized sheep. After left thoracotomy measuring transducers were placed and the assist device connected between the left-atrial appendage and the descending thoracic aorta. Global hemodynamics were measured before and after unloading was performed. Myocardial stunning was induced by transient occlusion of a coronary artery for 15 minutes and regional myocardial wall thickening was measured. A group without unloading served as controls (group I, n=4). In a second group unloading was performed during the last ten minutes of ischemia (group II, n=4) and in a third group unloading was performed for 30 minutes starting after ten minutes of reperfusion (group III, n=4). After starting the Medos(R) HIA-VAD(R), significant unloading could be demonstrated: left-ventricular dP/dt(max) decreased significantly (p<0.05) to 54% and 61% in groups II and III and left-atrial pressure to 50% and 71%, respectively. Systolic and mean arterial pressure did not change significantly (p<0.05), while the diastolic pressure increased (p<0.05) to 134% and 138% in groups II and III. After mechanical unloading whether during ischemia or during reperfusion systolic wall thickening in the postischemic area recovered to 103% and 92% of preischemic control in groups II and III, respectively. Recovery was incomplete in the non-unloaded controls (76%) (p<0.05 versus groups II and III). Post-ejection thickening, a diastolic measure of stunning, diminished significantly after unloading in both protocols (p<0.05 for groups II and III versus group I). We conclude that mechanical unloading with the 60 ml Medos(R) HIA-VAD(R) significantly improves recovery from myocardial stunning.
引用
收藏
页码:313 / 319
页数:7
相关论文
共 50 条
  • [1] IN-VIVO EVALUATION OF THE HIA-VAD - A NEW GERMAN VENTRICULAR ASSIST DEVICE
    RAKHORST, G
    HENSENS, AG
    VERKERKE, GJ
    BLANKSMA, PK
    BOM, VJJ
    ELSTRODT, J
    MAGIELSE, CPE
    VANDERMEER, J
    EILERS, R
    RUEL, H
    THORACIC AND CARDIOVASCULAR SURGEON, 1994, 42 (03): : 136 - 140
  • [2] LEFT-VENTRICULAR ASSIST DEVICE SYSTEM CONSIDERATIONS
    MOISE, JC
    BUTLER, KC
    WAMPLER, R
    FUJIMOTO, L
    SMITH, W
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1984, 31 (08) : 564 - 564
  • [3] Impact of Continuous Versus Pulsatile Unloading Pattern on Myocardial Matrix Biomarkers in Patients with Left Ventricular Assist Device
    Kato, T. S.
    Chokshi, A.
    Singh, P.
    Cheema, F.
    Akashi, H.
    Shahzad, K.
    Iwata, S.
    Homma, S.
    Takayama, H.
    Naka, Y.
    Jorde, U.
    Farr, M.
    Mancini, D.
    Schulze, C. P.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2011, 30 (04): : S76 - S77
  • [4] STUDY OF THE TRANSAPICAL LEFT-VENTRICULAR BYPASS COMBINED WITH PULSATILE ASSIST DEVICE
    TAGAMI, S
    MOCHIZUKI, T
    MATSUMURA, M
    IWAMIYA, H
    OHOTSUBO, A
    HIRONAKA, T
    NAKAGAKI, M
    TAGUCHI, K
    ARTIFICIAL ORGANS, 1981, 5 (03) : 319 - 319
  • [5] INTRAOPERATIVE TRANSESOPHAGEAL ECHOCARDIOGRAPHY FOR IMPLANTATION OF A PULSATILE LEFT-VENTRICULAR ASSIST DEVICE
    GEORGE, SJ
    BLACK, JJM
    BOSCOE, MJ
    BRITISH JOURNAL OF ANAESTHESIA, 1995, 75 (06) : 794 - 797
  • [6] Pre-clinical evaluation of a novel, pneumatic, ventricular assist device (Medos(R) HIA-VAD(R)) under pathophysiological conditions
    Waldenberger, FR
    Meyns, B
    Reul, H
    Eilers, R
    Flameng, W
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1997, 20 (07): : 389 - 396
  • [7] Left ventricular pressure and volume unloading during pulsatile versus nonpulsatile left ventricular assist device support
    Klotz, S
    Deng, MC
    Stypmann, J
    Roetker, J
    Wilhelm, MJ
    Hammel, D
    Scheld, HH
    Schmid, C
    ANNALS OF THORACIC SURGERY, 2004, 77 (01): : 143 - 149
  • [8] Myocardial Recovery by Mechanical Unloading With Left Ventricular Assist System
    Matsumiya, Goro
    Saitoh, Shunsuke
    Sakata, Yasushi
    Sawa, Yoshiki
    CIRCULATION JOURNAL, 2009, 73 (08) : 1386 - 1392
  • [9] EVALUATION OF THE PULSATILITY OF A NEW PULSATILE LEFT-VENTRICULAR ASSIST DEVICE - THE INTEGRATED CARDIOASSIST CATHETER - IN DOGS
    IDE, H
    YAMAGUCHI, A
    INO, T
    ADACHI, H
    MIZUHARA, A
    KAWAHITO, K
    MATSUMOTO, H
    FUJIMASA, I
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1994, 107 (02): : 569 - 575
  • [10] Recovery-directed left ventricular assist device (RDLVAD): Influence of its main components on left ventricular unloading
    不详
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2005, 28 (09): : 893 - 893