AN ACCORDION LIQUID ARGON ELECTROMAGNETIC CALORIMETER WITH ABSORBER IN ALL ELECTRODES

被引:1
|
作者
BENARY, O
CLELAND, W
FERGUSON, I
GORDEEV, A
GORDON, H
KISTENEV, E
KROON, P
LELTCHOUK, M
LISSAUER, D
MA, H
MAKOWIECKI, D
MASLENNIKOV, A
MCCORKLE, S
ONOPRIENKO, D
ONUCHIN, A
OREN, Y
PANIN, V
PARSONS, JA
RADEKA, V
ROGERS, L
RAHM, D
RESCIA, S
RUTHERFOORD, J
SEMAN, M
SMITH, M
SONDERICKER, J
STEINER, R
STEPHANI, D
STERN, E
STUMER, I
TAKAI, H
THEMANN, H
TIKHONOV, Y
WILLIS, W
机构
[1] BROOKHAVEN NATL LAB,UPTON,NY 11973
[2] ADELPHI UNIV,GARDEN CITY,NY 11530
[3] UNIV ARIZONA,TUCSON,AZ 85721
[4] OAK RIDGE NATL LAB,OAK RIDGE,TN 37831
[5] UNIV PITTSBURGH,PITTSBURGH,PA 15260
[6] BUDKER INST NUCL PHYS,NOVOSIBIRSK,RUSSIA
[7] TEL AVIV UNIV,IL-69978 TEL AVIV,ISRAEL
[8] SUNY STONY BROOK,STONY BROOK,NY 11794
[9] COLUMBIA UNIV,NEVIS LABS,IRVINGTON,NY 10533
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 1994年 / 350卷 / 1-2期
基金
美国国家科学基金会;
关键词
D O I
10.1016/0168-9002(94)91157-6
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A prototype electromagnetic liquid argon calorimeter with accordion geometry, using absorber material in all electrodes, has been constructed and tested. This construction results in twice the sampling frequency compared to the conventional accordion electrode structure. The energy resolution, measured with 15 GeV electrons, was found to be 6.3%/square-rootE, in good agreement with the value expected from Monte Carlo simulations.
引用
收藏
页码:131 / 135
页数:5
相关论文
共 50 条
  • [1] PERFORMANCE OF AN ACCORDION ELECTROMAGNETIC CALORIMETER WITH LIQUID KRYPTON AND ARGON
    BENARY, O
    CLELAND, W
    FERGUSON, I
    GORDEEV, A
    GORDON, H
    KISTENEV, E
    KROON, P
    LELTCHOUK, M
    LISSAUER, D
    MA, H
    MAKOWIECKI, D
    MASLENNIKOV, A
    MCCORKLE, S
    ONOPRIENKO, D
    ONUCHIN, A
    OREN, Y
    PANIN, V
    PARSONS, JA
    RADEKA, V
    ROGERS, L
    RAHM, D
    RESCIA, S
    RUTHERFOORD, J
    SEMAN, M
    SMITH, M
    SONDERICKER, J
    STEINER, R
    STEPHANI, D
    STERN, E
    STUMER, I
    TAKAI, H
    THEMANN, H
    TIKHONOV, Y
    WILLIS, WJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 344 (02): : 363 - 377
  • [2] PERFORMANCE OF A LIQUID ARGON ELECTROMAGNETIC CALORIMETER WITH AN ACCORDION GEOMETRY
    AUBERT, B
    BAZAN, A
    CAVANNA, F
    COLAS, J
    LEFLOUR, T
    VIALLE, JP
    GORDON, HA
    POLYCHRONAKOS, V
    RADEKA, V
    RAHM, D
    STEPHANI, D
    BAISIN, L
    BERSET, JC
    FABJAN, CW
    FOURNIER, D
    GILDEMEISTER, O
    JENNI, P
    LEFEBVRE, M
    MARIN, CP
    NESSI, M
    NESSITEDALDI, F
    PEPE, M
    POLESELLO, G
    RICHTER, W
    SIGRIST, A
    WILLIS, WJ
    CAMIN, DV
    COSTA, G
    GIANOTTI, F
    MANDELLI, L
    PESSINA, G
    ICONOMIDOUFAYARD, L
    MERKEL, B
    PETROFF, P
    REPELLIN, JP
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 309 (03): : 438 - 449
  • [3] PERFORMANCE OF THE LIQUID ARGON ELECTROMAGNETIC AND HADRONIC ACCORDION CALORIMETER FOR THE LHC
    GINGRICH, D
    GREENIOUS, G
    KITCHING, P
    OLSEN, B
    PINFOLD, J
    RODNING, N
    BOOS, E
    SCHAOUTNIKOV, BO
    AUBERT, B
    BAZAN, A
    BEAUGIRAUD, B
    COLAS, J
    LEFLOUR, T
    MARIE, M
    STIPCEVIC, M
    WINGERTERSEEZ, I
    ZOLNIEROWSKI, YP
    CHEMEISSIANI, M
    FERNANDEZ, E
    GARRIDO, L
    MARTINEZ, M
    PADILLA, C
    GORDON, HA
    RADEKA, V
    RAHM, D
    STEPHANI, D
    CHEVALLEY, JL
    FABJAN, CW
    GILDEMEISTER, O
    JENNI, P
    NESSI, M
    POGGIOLI, L
    RICHTEL, W
    VUILLEMIN, V
    BAZE, JM
    GOSSET, L
    LAVOCAT, P
    LOTTIN, JP
    MANSOULIE, B
    MEYER, JP
    RENARDY, JF
    SCHWINDLING, J
    TEIGER, J
    ZACCONE, H
    COLLOT, J
    DESAINTIGNON, P
    DZAHINI, D
    LABORIE, G
    MAHOUT, G
    MERCHEZ, E
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 344 (01): : 39 - 46
  • [4] PERFORMANCE OF A LIQUID ARGON ELECTROMAGNETIC CALORIMETER WITH A CYLINDRICAL ACCORDION GEOMETRY
    AUBERT, B
    BAZAN, A
    BEAUGIRAUD, B
    COLAS, J
    LEFLOUR, T
    MAIRE, M
    VIALLE, JP
    WINGERTERSEEZ, I
    ZOLNIEROWSKI, YP
    GORDON, HA
    RADEKA, V
    RAHM, D
    STEPHANI, D
    BULGAKOV, N
    CHEVALLEY, JL
    FABJAN, CW
    FOURNIER, D
    GILDEMEISTER, O
    JENNI, P
    NESSI, M
    NESSITEDALDI, F
    PEPE, M
    RICHTER, W
    SODERQVIST, J
    VUILLEMIN, V
    BAZE, JM
    GOSSET, L
    LAVOCAT, P
    LOTTIN, JP
    MANSOULIE, B
    MEYER, JP
    RENARDY, JR
    TEIGER, J
    ZACCONE, H
    BATTISTONI, G
    CAMIN, DV
    CAVALLI, D
    COSTA, G
    CRAVERO, A
    FERRARI, A
    GIANOTTI, F
    MANDELLI, L
    MAZZANTI, M
    PERINI, L
    SCIAMANNA, M
    AUGE, E
    CHASE, R
    CHOLLET, JC
    DELATAILLE, C
    FAYARD, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 325 (1-2): : 116 - 128
  • [5] Performance of the liquid argon electromagnetic and hadronic accordion calorimeter for the LHC
    Gingrich, D.
    Greenious, G.
    Kitching, P.
    Olsen, B.
    Pinfold, J.
    Rodning, N.
    Boos, E.
    Schaoutnikov, B.O.
    Aubert, B.
    Bazan, A.
    Beaugiraud, B.
    Colas, J.
    Leflour, T.
    Marie, M.
    Stipcevic, M.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1994, A344 (01) : 39 - 46
  • [6] PERFORMANCE OF A LIQUID ARGON ACCORDION HADRONIC CALORIMETER PROTOTYPE
    GINGRICH, DM
    GREENIAUS, G
    KITCHING, P
    OLSEN, B
    PINFOLD, JL
    RODNING, NL
    BOOS, E
    SCHAOUTNIKOV, BO
    AUBERT, B
    BAZAN, A
    BEAUGIRAUD, B
    BONIFACE, J
    COLAS, J
    JEZEQUEL, S
    LEFLOUR, T
    MAIRE, M
    RIVAL, F
    STIPCEVIC, M
    THION, J
    VANDENPLAS, D
    WINGERTERSEEZ, I
    ZOLNIEROWSKI, YP
    CHMEISSANI, M
    FERNANDEZ, E
    GARRIDO, L
    MARTINEZ, M
    PADILLA, C
    GORDON, HA
    RADEKA, V
    RAHM, D
    STEPHANI, D
    CHEVALLEY, JL
    GIANOTTI, F
    NESSI, M
    POGGIOLI, L
    VUILLEMIN, V
    BAZE, JM
    GOSSET, L
    LAVOCAT, P
    LOTTIN, JP
    MANSOULIE, B
    MEYER, JP
    RENARDY, JF
    SCHWINDLING, J
    TEIGER, J
    COLLOT, J
    DESAINTIGNON, P
    DZAHINI, D
    HOSTACHY, JY
    LABORIE, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 355 (2-3): : 295 - 307
  • [7] Performance of a liquid argon accordion calorimeter with faster readout
    Aubert, B.
    Bazan, A.
    Beaugiraud, B.
    Colas, J.
    Leflour, T.
    Maire, M.
    Vialle, J.P.
    Wingerter-Seez, I.
    Zolnierowski, Y.P.
    Gordon, H.A.
    Radeka, V.
    Rahm, D.
    Stephani, D.
    Chevalley, J.L.
    Fabjan, C.W.
    Fournier, D.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1992, A321 (03) : 467 - 478
  • [8] PERFORMANCE OF A LIQUID ARGON ACCORDION CALORIMETER WITH FAST READOUT
    AUBERT, B
    BAZAN, A
    BEAUGIRAUD, B
    COLAS, J
    LEFLOUR, T
    MAIRE, M
    VIALLE, JP
    WINGERTERSEEZ, I
    ZOLNIEROWSKI, YP
    GORDON, HA
    RADEKA, V
    RAHM, D
    STEPHANI, D
    CHEVALLEY, JL
    FABJAN, CW
    FOURNIER, D
    FRANZ, A
    GILDEMEISTER, O
    JENNI, P
    NESSI, M
    NESSITEDALDI, F
    PEPE, M
    RICHTER, W
    SODERQVIST, J
    BAZE, JM
    GOSSET, L
    LAVOCAT, P
    LOTTIN, JP
    MANSOULIE, B
    MEYER, JP
    RENARDY, JF
    TEIGER, J
    ZACCONE, H
    BATTISTONI, G
    CAMIN, DV
    CAVALLI, D
    COSTA, G
    CRAVERO, A
    FERRARI, A
    GIANOTTI, F
    MANDELLI, L
    MAZZANTI, M
    PERINI, L
    PESSINA, G
    SALA, P
    SCIAMANNA, M
    AUGE, E
    CHASE, R
    CHOLLET, JC
    DELATAILLE, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 321 (03): : 467 - 478
  • [9] PERFORMANCE OF A LIQUID ARGON PRESHOWER DETECTOR INTEGRATED WITH AN ACCORDION CALORIMETER
    AUBERT, B
    BAZAN, A
    BEAUGIRAUD, B
    COLAS, J
    LEFLOUR, T
    MAIRE, M
    VIALLE, JP
    WINGERTERSEEZ, I
    ZOLNIEROWSKI, YP
    GORDON, HA
    RADEKA, V
    RAHM, D
    STEPHANI, D
    BULGAKOV, N
    CHEVALLEY, JL
    FABJAN, CW
    FOURNIER, D
    GILDEMEISTER, O
    JENNI, P
    NESSI, M
    NESSITEDALDI, F
    PEPE, M
    RICHTER, W
    SODERQVIST, J
    VUILLEMIN, V
    BAZE, JM
    GOSSET, L
    LAVOCAT, P
    LOTTIN, JP
    MANSOULIE, B
    MEYER, JP
    RENARDY, JF
    TEIGER, J
    ZACCONE, H
    BATTISTONI, G
    CAMIN, DV
    CAVALLI, D
    COSTA, G
    CRAVERO, A
    FERRARI, A
    GIANOTTI, F
    MANDELLI, L
    MAZZANTI, M
    PERINI, L
    PESSINA, G
    SCIAMANNA, M
    AUGE, E
    CHASE, R
    CHOLLET, JC
    DELATAILLE, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 330 (03): : 405 - 415
  • [10] The ATLAS Liquid Argon electromagnetic calorimeter
    Pralavorio, P
    INTERSECTIONS OF PARTICLE AND NUCLEAR PHYSICS, 2000, 549 : 872 - 874