AN INVESTIGATION OF SIMULATED UMBILICAL ARTERY DOPPLER WAVE-FORMS .2. A COMPARISON OF 3 DOPPLER WAVE-FORM QUALITY INDEXES

被引:2
|
作者
HOSKINS, PR
机构
[1] Department of Medical Physics and Medical Engineering, Royal Infirmary of Edinburgh, Edinburgh
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 1991年 / 17卷 / 01期
关键词
DOPPLER ULTRASOUND; MAXIMUM FREQUENCY ENVELOPE; WAVE-FORM QUALITY INDEX;
D O I
10.1016/0301-5629(91)90005-H
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Three Doppler waveform quality indices based upon assessment of the noise of the maximum frequency envelope of simulated umbilical artery waveforms were investigated. These indices were: an estimate of the correlation between successive waveforms (QI1), a local linearity measure (QI2) and a ratio of two regions of the Fourier transform amplitude spectrum of the maximum frequency envelope (QI3). Simulated umbilical artery waveforms were acquired from a physiological flow phantom. A test population was used consisting of a large number of waveforms where one of three physical variables had been adjusted to produce waveforms of varying quality. These three physical variables were: beam-vessel angle, beam-vessel axial misalignment and attenuator thickness. For this group of waveforms the accuracy of estimation of the maximum frequency envelope and pulsatility index (PI) were known. All three quality indices gave good separation of high- and low-quality waveforms based upon threshold values of the accuracy of PI and maximum frequency envelope. The dependence of each quality index on fetal breathing, waveform length and waveform pulsatility was investigated. QI2, the local linearity measure, showed most promise in its independence from these variables.
引用
收藏
页码:23 / 30
页数:8
相关论文
共 50 条
  • [1] A COMPARISON OF DOPPLER ULTRASOUND WAVE-FORM INDEXES IN THE UMBILICAL ARTERY .2. INDEXES DERIVED FROM THE MEAN VELOCITY AND 1ST MOMENT WAVE-FORMS
    THOMPSON, RS
    TRUDINGER, BJ
    COOK, CM
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1986, 12 (11): : 845 - 854
  • [2] CLINICAL-TRIAL OF UMBILICAL ARTERY DOPPLER WAVE-FORM QUALITY INDEXES
    HOSKINS, PR
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (08): : 777 - 786
  • [3] A COMPARISON OF DOPPLER ULTRASOUND WAVE-FORM INDEXES IN THE UMBILICAL ARTERY .1. INDEXES DERIVED FROM THE MAXIMUM VELOCITY WAVE-FORM
    THOMPSON, RS
    TRUDINGER, BJ
    COOK, CM
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1986, 12 (11): : 835 - 844
  • [4] VARIABILITY OF CONTINUOUS-WAVE DOPPLER FLOW VELOCITY WAVE-FORM INDEXES FROM THE UMBILICAL ARTERY
    DAVIES, JA
    LEE, A
    SPENCER, JAD
    OBSTETRICS AND GYNECOLOGY, 1990, 76 (03): : 366 - 369
  • [5] PREGNANCY SCREENING BY DOPPLER UTEROPLACENTAL AND UMBILICAL ARTERY WAVE-FORMS
    TRUDINGER, B
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1990, 97 (03): : 278 - 279
  • [6] CONTINUOUS MONITORING OF DOPPLER UMBILICAL ARTERY WAVE-FORMS IN LABOR
    ABITBOL, MM
    ROCHELSON, B
    CASTILLO, I
    TAYLOR, U
    UDOMRICE, I
    WANG, HP
    JOURNAL OF MATERNAL-FETAL INVESTIGATION, 1992, 2 (01): : 45 - 49
  • [7] RENAL-ARTERY DOPPLER WAVE-FORMS IN NEONATES WITH UMBILICAL ARTERY CATHETERS
    GLICKSTEIN, J
    FRIEDMAN, D
    SCHACHT, R
    RUTKOWSKI, M
    CLINICAL RESEARCH, 1991, 39 (03): : A669 - A669
  • [8] PREGNANCY SCREENING BY DOPPLER UTEROPLACENTAL AND UMBILICAL ARTERY WAVE-FORMS - REPLY
    HANRETTY, KP
    NEILSON, JP
    WHITTLE, MJ
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1990, 97 (03): : 279 - 279
  • [9] DOPPLER UMBILICAL ARTERY FLOW VELOCITY WAVE-FORMS IN DIABETIC PREGNANCY
    JOHNSTONE, FD
    STEEL, JM
    HADDAD, NG
    HOSKINS, PR
    GREER, IA
    CHAMBERS, S
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1992, 99 (02): : 135 - 140
  • [10] THE USE OF DOPPLER UMBILICAL ARTERY WAVE-FORMS IN PLACENTAL ABRUPTION - A REPORT OF 2 CASES
    RAFLA, NM
    EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 1991, 38 (02): : 167 - 168