MICROPREPARATIVE CAPILLARY ISOELETRIC FOCUSING OF PROTEIN AND PEPTIDE SAMPLES FOLLOWED BY PROTEIN SEQUENCING

被引:0
|
作者
GRIMM, R [1 ]
机构
[1] HEWLETT PACKARD GMBH,ANALYT DIV EUROPE,D-76337 WALDBRONN,GERMANY
关键词
CAPILLARY ISOELECTRIC FOCUSING; FULLY AUTOMATED FRACTION COLLECTION; PROTEIN SEQUENCING;
D O I
暂无
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
This paper presents a simple, straightforward method for fully automated micropreparative capillary isoelectric focusing (CIEF) of protein and pep tide samples, including fully automated fraction collection from single runs followed by protein sequencing. Protein and peptide samples were separated by native CIEF. Micropreparative CIEF of proteins was carried out using capillaries with 100-mu m inner diameter; 75-mu m-i.d. capillaries were used for micropreparative CIEF of peptides. Protein and peptide components were automatically collected into vials containing carrier ampholytes and reinjected to confirm successful fraction collection. Remaining protein and peptide fractions containing carrier ampholytes were loaded directly onto the protein sequencer support without any further sample pretreatment. Protein samples were sequenced for up to 45 cycles.
引用
收藏
页码:111 / 115
页数:5
相关论文
共 50 条
  • [1] Micropreparative isoelectric focusing protein separation in a suspended drop
    Egatz-Gomez, Ana
    Thormann, Wolfgang
    ELECTROPHORESIS, 2011, 32 (12) : 1433 - 1437
  • [2] Capillary electrophoresis and isoelectric focusing in peptide and protein analysis
    Righetti, Pier Giorgio
    Sebastiano, Roberto
    Citterio, Attilio
    PROTEOMICS, 2013, 13 (02) : 325 - 340
  • [3] THE USE OF MICROPREPARATIVE ELECTROPHORESIS OF PROTEIN PEPTIDE ISOLATIONS FOR PRIMARY STRUCTURE DETERMINATIONS
    SHEER, DG
    YAMANE, DK
    HAWKE, DH
    YUAN, PM
    BIOTECHNIQUES, 1990, 9 (04) : 486 - &
  • [4] Protein sequencing and peptide synthesis
    Hammar, F
    NACHRICHTEN AUS CHEMIE TECHNIK UND LABORATORIUM, 1997, 45 : S101 - S109
  • [5] Protein sequencing and peptide synthesis
    Hammar, F
    NACHRICHTEN AUS CHEMIE TECHNIK UND LABORATORIUM, 1997, 45 (10): : M71 - M79
  • [6] Capillary isoelectric focusing: The problem of protein solubility
    Conti, M
    Galassi, M
    Bossi, A
    Righetti, PG
    JOURNAL OF CHROMATOGRAPHY A, 1997, 757 (1-2) : 237 - 245
  • [7] Capillary isoelectric focusing -: reproducibility and protein adsorption
    Graf, M
    Wätzig, H
    ELECTROPHORESIS, 2004, 25 (17) : 2959 - 2964
  • [8] Capillary isoelectric focusing of the scrapie prion protein
    Schmerr, MJ
    Cutlip, RC
    Jenny, A
    JOURNAL OF CHROMATOGRAPHY A, 1998, 802 (01) : 135 - 141
  • [9] APPLICATION OF CAPILLARY ISOELECTRIC-FOCUSING WITH UNIVERSAL CONCENTRATION GRADIENT DETECTOR TO THE ANALYSIS OF PROTEIN SAMPLES
    WU, J
    PAWLISZYN, J
    JOURNAL OF CHROMATOGRAPHY, 1992, 608 (1-2): : 121 - 130
  • [10] AUTOMATED SUBPICOMOLE LEVEL PROTEIN AND PEPTIDE SEQUENCING
    NIKA, H
    CHOW, DT
    BURES, EJ
    HESS, D
    MORRISON, HD
    AEBERSOLD, R