MARGINAL LEAKAGE OF VISIBLE LIGHT-CURED GLASS-IONOMER RESTORATIVE MATERIALS

被引:35
|
作者
CRIM, GA
机构
[1] School of Dentistry, University of Louisville, Louisville, KY
来源
JOURNAL OF PROSTHETIC DENTISTRY | 1993年 / 69卷 / 06期
关键词
D O I
10.1016/0022-3913(93)90281-R
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study examined the sealing of two visible light-cured glass ionomer restorative materials and a conventional glass ionomer. Class V cavity preparations were completed at the cementoenamel junction on the facial and lingual surfaces of extracted human molars. The cavity preparations were restored with either VariGlass VLC, GC Fuji II LC, or GC Fuji II glass ionomer cements. The restored teeth were thermocycled, immersed in fuchsin dye for 24 hours, sectioned, and evaluated with a measuring microscope. No microleakage occurred at the enamel/glass ionomer or dentin/glass ionomer cement interfaces of any samples, but the enamel adjacent to the VariGlass glass ionomer cement restorations exhibited crazing and staining.