DEPTH-DOSE IN AN ANTHROPOMORPHIC HEAD PHANTOM FOR MONOENERGETIC PHOTONS

被引:0
|
作者
SHARAF, MA
机构
[1] Ministry of Scientific Research, National Institute for Standards, Dokki, Cairo
来源
RADIATION PHYSICS AND CHEMISTRY | 1994年 / 44卷 / 04期
关键词
D O I
10.1016/0969-806X(94)90078-7
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Depth-dose distribution measurements in an anthropomorphic phantom exposed to a broad parallel beam of different monoenergetic photons (X-ray, Cs-137 and Co-60) were studied. The depth dose was measured by setting BeO-TLDs in the phantom. From the view point of clinical dosimetry, for low energy X-rays < 100 keV, the dose is high and jumps at the head bone interface while for high energy photons, the differential at the interface is not great. The dose to tissue at the interface is high. Thus, in the case of higher energy photon beams, higher doses can be delivered to the deep-seated tumours without exceeding the tolerance of the scalp.
引用
收藏
页码:395 / 398
页数:4
相关论文
共 50 条
  • [1] CALCULATED DEPTH DOSE DISTRIBUTIONS IN AN ANTHROPOMORPHIC PHANTOM
    SCHERPELZ, RI
    TANNER, JE
    BRACKENBUSH, LW
    HEALTH PHYSICS, 1987, 52 : S68 - S69
  • [2] DEPTH-DOSE DISTRIBUTION MEASUREMENTS AND CALCULATIONS IN AN ELLIPTICAL PHANTOM
    PALFALVI, J
    KOBLINGER, L
    SZABO, PP
    HEALTH PHYSICS, 1983, 44 (01): : 35 - 44
  • [3] Thermoluminescence needle difference dosimeter for depth-dose distribution in phantom
    Kubu, M
    PATRAS MEDICAL PHYSICS 99, 1999, : 143 - 148
  • [4] Evaluation of depth-dose profiles in a water phantom at the BNCT facility at BINP
    Bykov, T. A.
    Kasatov, D. A.
    Koshkarev, A. M.
    Makarov, A. N.
    Leonov, V. V.
    Porosev, V. V.
    Savinov, G. A.
    Savinov, S. S.
    Shchudlo, I. M.
    Taskaev, S. Yu
    Verkhovod, G. D.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (10)
  • [5] Measurements of depth-dose distributions in a phantom for gadolinium Neutron capture therapy
    Matsumoto, T
    Tsuruno, A
    CANCER NEUTRON CAPTURE THERAPY, 1996, : 517 - 522
  • [6] PROTON DEPTH-DOSE DOSIMETRY
    MITCHELL, JC
    DALRYMPLE, GV
    WILLIAMS, GH
    HALL, JD
    MORGAN, IL
    RADIATION RESEARCH, 1966, 28 (02) : 390 - +
  • [7] DEPTH-DOSE SCANNING DEVICE
    MAUDERLI, W
    HAZARD, B
    RADIOLOGY, 1965, 84 (01) : 130 - &
  • [8] LIF DEPTH-DOSE MEASUREMENTS
    HENDEE, WR
    GOLDEN, R
    GARCIGA, CE
    GILBERT, DB
    IBBOTT, GS
    RADIOLOGY, 1968, 90 (02) : 371 - &
  • [9] DISTRIBUTION OF DOSE EQUIVALENT IN AN ANTHROPOMORPHIC PHANTOM RESULTING FROM BROAD-BEAM SOURCES OF MONOENERGETIC NEUTRONS
    SNYDER, WS
    AUXIER, JA
    BROWN, MD
    JONES, TD
    BOUGHNER, RT
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1966, 9 (02): : 357 - +
  • [10] The antiproton depth-dose curve in water
    Bassler, N.
    Holzscheiter, M. H.
    Jaekel, O.
    Knudsen, H. V.
    Kovacevic, S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (03): : 793 - 805