摘要
Situations may arise during elective and emergency surgery when vascular control is required but conventional vascular clamps cannot be used. We have found the Foley catheter useful for the control of inadvertent perforation of the heart especially in ''redo'' operations. We describe the use of the Foley catheter for the control of the difficult aorta and illustrate its potential versatility in a variety of uncommon situations. As Foley catheters are present in every operating theatre we hope that our experience will be of benefit to other surgeons who encounter similar problems.
引用
收藏
页码:617 / 619
页数:3
相关论文
共 50 条
  • [1] THE USE OF BALLOON-TIPPED PULMONARY-ARTERY CATHETERS IN CHILDREN UNDERGOING CARDIAC-SURGERY
    DAMEN, J
    WEVER, JEAT
    INTENSIVE CARE MEDICINE, 1987, 13 (04) : 266 - 272
  • [2] USE OF CATHETERS IN CARDIAC-SURGERY, WITH SPECIAL REFERENCE TO THEIR BREAKING
    IRIARTE, A
    JUFFE, A
    QUINTERO, E
    FIGUERA, D
    CIRUGIA ESPANOLA, 1977, 31 (06): : 489 - 492
  • [3] USE OF INTRA-AORTIC BALLOON IN CARDIAC-SURGERY
    LIMET, R
    MAILLE, JG
    LEPAGE, G
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1976, 69 (05): : 495 - 502
  • [4] PREINDUCTION USE OF PULMONARY-ARTERY CATHETERS DURING CARDIAC-SURGERY
    SNOW, N
    CHEST, 1983, 83 (03) : 587 - 587
  • [5] eComment. Balloon catheters in cardiac surgery
    Assar, Omid
    Motamedi, Mohammadhasan Kalantar
    Saleh, Davoud Kazemi
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2013, 17 (01) : 217 - 218
  • [6] USE OF AN INTRA-AORTIC BALLOON IN CARDIAC-SURGERY - WITH REFERENCE TO 2 CASES
    SOYER, R
    EISENMANN, B
    RIBEROLLES, CD
    HAAS, C
    DIAMANTBERGER, F
    LETAC, B
    LEROUX, G
    TOUCHOT, B
    ANNALES DE CHIRURGIE, 1975, 14 (01): : 17 - 19
  • [7] INDICATIONS FOR ELECTIVE USE OF INTRA-AORTIC BALLOON PUMP IN CARDIAC-SURGERY
    BOLOOKI, H
    WILLIAMS, W
    VARGAS, A
    KAISER, G
    GHAHRAMANI, A
    CLINICAL RESEARCH, 1975, 23 (03): : A173 - A173
  • [8] USE OF HES IN CARDIAC-SURGERY
    BELCHER, P
    ANNALS OF THORACIC SURGERY, 1985, 40 (04): : 416 - 416
  • [9] PARAPLEGIA FOLLOWING BALLOON ASSISTANCE AFTER CARDIAC-SURGERY
    CRIADO, A
    AGOSTI, J
    HORNO, R
    JIMENEZ, C
    SCANDINAVIAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1981, 15 (01): : 103 - 104
  • [10] CURRENT STATUS OF INTRAAORTIC BALLOON COUNTERPULSATION IN CARDIAC-SURGERY
    PAULUS, S
    BASTIEN, O
    HERCULE, C
    ESTANOVE, S
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1992, 85 (12): : 1805 - 1810