A COMPUTERIZED BIOELECTRICAL CARDIAC MONITOR

被引:0
|
作者
JOSSINET, J [1 ]
LEFTHERIOTIS, G [1 ]
VERNIER, F [1 ]
SAUMET, JL [1 ]
机构
[1] CTR HOSP REG & UNIV ANGERS, F-49045 ANGERS, FRANCE
关键词
Cardiac contractility; Cardiac output; Electrical bio-impedance; Microcomputer; Signal processing;
D O I
10.1016/0010-4825(90)90050-Y
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The use of a micro-computer improves the performance of an impedance cardiograph. The impedance signals and the ECG are real-time processed and four analog signals are displayed on the screen. A beat-to-beat estimation of cardiac output and several indexes are computed and displayed. User's interface is by interactive screen menus. Some facilities permit data identification, storage and post-processing. The software has been designed in such a way as to be adaptable to each specific application and to enable the development of new routines for cardiac signal processing. The signals recorded in healthy patients are in agreement with the results of other similar studies. © 1990.
引用
收藏
页码:253 / 260
页数:8
相关论文
共 50 条
  • [1] A FATAL ARRHYTHMIA UNDETECTED BY A COMPUTERIZED CARDIAC MONITOR
    BRINBERG, D
    BERKELEY, B
    NASH, I
    [J]. ANNALS OF INTERNAL MEDICINE, 1987, 106 (02) : 326 - 326
  • [2] COMPUTERIZED PORTAL MONITOR
    LATTIN, KR
    HANSON, DE
    [J]. HEALTH PHYSICS, 1977, 33 (06): : 659 - 659
  • [3] The application of bioelectrical impedance to monitor leg movement
    Song, CG
    Kim, DW
    [J]. IEICE TRANSACTIONS ON INFORMATION AND SYSTEMS, 2005, E88D (01): : 164 - 168
  • [4] COMPUTERIZED MONITORING OF BIOELECTRICAL BRAIN ACTIVITY AT ASSISTED CIRCULATION
    BUNATYAN, AA
    OSIPOV, VP
    FLEROV, EV
    MIERBEKOV, EM
    GEORGIEVSKAYA, EY
    TOLMACHEV, VA
    ROMANOV, VA
    [J]. VESTNIK AKADEMII MEDITSINSKIKH NAUK SSSR, 1988, (09): : 16 - 24
  • [5] SIMULTANEOUS COMPUTERIZED ASSESSMENT OF BIOELECTRICAL ACTIVITY AND HEMODYNAMIC PARAMETERS
    BOGDANOV, EG
    ZAITSEV, AA
    TSURINOV, AD
    UDOVICHENKO, NA
    [J]. BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE, 1987, 103 (05) : 654 - 656
  • [6] COMPUTERIZED ANALYSIS OF HOLTER MONITOR TAPES
    FOX, W
    KACZKOWSKI, DJ
    [J]. ANNALS OF INTERNAL MEDICINE, 1985, 102 (05) : 716 - 717
  • [7] CARDIAC MONITOR
    ANDREOLI, KG
    [J]. AMERICAN JOURNAL OF NURSING, 1969, 69 (06) : 1238 - 1243
  • [8] Computerized cardiac mapping
    Ellenbogen, K
    Furman, S
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2002, 25 (01): : 2 - 3
  • [9] COMPUTERIZED PORTABLE 9 DECADE RADIATION MONITOR
    DIIANNI, E
    COOLEY, HJ
    [J]. HEALTH PHYSICS, 1984, 47 (01): : 176 - 177
  • [10] Evaluation of a computerized telephone system to monitor falls
    van der Marck, M. A.
    Klok, M. Ph C.
    Overeem, S.
    Bloem, B. R.
    Munneke, M.
    [J]. MOVEMENT DISORDERS, 2009, 24 : S270 - S271