X-RAY-IMAGING ARRAYS FOR IMPURITY TRANSPORT STUDIES ON THE TEXAS-EXPERIMENTAL-TOKAMAK

被引:20
|
作者
WENZEL, KW
PETRASSO, RD
机构
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1990年 / 61卷 / 02期
关键词
D O I
10.1063/1.1141480
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Three multichannel soft x-ray imaging arrays are used for impurity transport studies on the Texas Experimental Tokamak. The entire system has a total of 92 broadband x-ray detectors that view the plasma at the same toroidal location from three different poloidal angles: Array A is a 40-channel vertically viewing set of silicon surface barrier diodes (SBDs); array B is a 40-channel horizontally viewing set of SBDs; and array C is a 12-channel set of p-intrinsic-n (p-i-n) detectors viewing the plasma from 45° above the horizontal plane. Array B is absolutely calibrated; array A is relatively calibrated in situ; and array C is cross-calibrated relative to array B. In this article we describe the primary components of the system: (1) the specific x-ray diodes used for the arrays and their spectral sensitivities; (2) the corresponding electronics necessary for data acquisition; and (3) the vacuum system for the arrays. Furthermore, we describe a novel krypton edge absorption filter which discriminates between the resonance line radiation of He-like and H-like aluminum injected into TEXT plasmas.
引用
收藏
页码:693 / 700
页数:8
相关论文
共 50 条
  • [1] X-RAY-IMAGING OF IMPURITY TRANSPORT
    PETRASSO, RD
    WENZEL, KW
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (10): : 3144 - 3144
  • [2] IMPURITY TRANSPORT STUDIES IN THE TEXAS EXPERIMENTAL TOKAMAK (TEXT)
    HORTON, W
    ROWAN, W
    [J]. PHYSICS OF PLASMAS, 1994, 1 (04) : 901 - 908
  • [3] TOKAMAK FUSION TEST REACTOR X-RAY-IMAGING DIAGNOSTIC
    HILL, KW
    VONGOELER, S
    BITTER, M
    DAVIS, W
    DUDEK, L
    FREDD, E
    JOHNSON, LC
    KIRALY, J
    MCGUIRE, K
    MONTAGUE, J
    MOSHEY, E
    SAUTHOFF, NR
    YOUNG, KM
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1985, 56 (05): : 830 - 832
  • [4] USING X-RAY ARRAYS TO MEASURE IMPURITY TRANSPORT IN THE ALCATOR-C TOKAMAK
    PETRASSO, RD
    TERRY, J
    HOPF, J
    LOTER, N
    SEGUIN, FH
    DELGRANDE, NK
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1985, 56 (05): : 843 - 843
  • [5] X-RAY-IMAGING WITH TWO-DIMENSIONAL CCD ARRAYS
    KENNEDY, WH
    HERRON, JM
    GUR, D
    MILLER, SL
    GOOD, WF
    GOOD, BC
    [J]. MEDICAL PHYSICS, 1985, 12 (04) : 504 - 504
  • [6] X-RAY-IMAGING WITH TWO-DIMENSIONAL CCD ARRAYS
    KENNEDY, WH
    HERRON, JM
    GUR, D
    MILLER, SL
    GOOD, WF
    GOOD, BC
    LATCHAW, RE
    YONAS, H
    [J]. MEDICAL PHYSICS, 1984, 11 (03) : 386 - 386
  • [7] X-RAY-IMAGING WITH TWO-DIMENSIONAL CCD ARRAYS
    GUR, D
    HERRON, JM
    KENNEDY, WH
    GOOD, WF
    MILLER, SL
    GOOD, BC
    [J]. INVESTIGATIVE RADIOLOGY, 1984, 19 (05) : S39 - S39
  • [8] SPECTROSCOPIC DIAGNOSTIC FOR MEASUREMENT OF PLASMA ROTATION IN THE TEXAS-EXPERIMENTAL-TOKAMAK (TEXT)
    MEIGS, AG
    ROWAN, WL
    WOODWARD, NW
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (10): : 2952 - 2954
  • [9] CORE TURBULENCE AND TRANSPORT STUDIES ON THE TEXAS EXPERIMENTAL TOKAMAK
    BRAVENEC, RV
    GENTLE, KW
    RICHARDS, B
    ROSS, DW
    SING, DC
    WOOTTON, AJ
    BROWER, DL
    LUHMANN, NC
    PEEBLES, WA
    YU, CX
    CROWLEY, TP
    HEARD, JW
    HICKOK, RL
    SCHOCH, PM
    YANG, XZ
    [J]. PHYSICS OF FLUIDS B-PLASMA PHYSICS, 1992, 4 (07): : 2127 - 2135
  • [10] DIGITAL X-RAY-IMAGING
    COWEN, AR
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 1991, 2 (08) : 691 - 707