Clinical and physiological effects of transcranial electrical stimulation position on motor evoked potentials in scoliosis surgery

被引:7
|
作者
Lo, Y. L. [1 ]
Dan, Y. F. [2 ]
Tan, Y. E. [2 ]
Teo, A. [2 ]
Tan, S. B. [3 ]
Yue, W. M. [3 ]
Guo, C. M. [3 ]
Fook-Chong, S. [4 ]
机构
[1] Singapore Gen Hosp, Natl Neurosci Inst, Dept Neurol, Outram Rd, Singapore 169608, Singapore
[2] Singapore Gen Hosp, Dept Neurol, Singapore 169608, Singapore
[3] Singapore Gen Hosp, Dept Orthoped Surg, Singapore 169608, Singapore
[4] Singapore Gen Hosp, Dept Clin Res, Singapore 169608, Singapore
来源
关键词
D O I
10.1186/1748-7161-5-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: During intraoperative monitoring for scoliosis surgery, we have previously elicited ipsilateral and contralateral motor evoked potentials (MEP) with cross scalp stimulation. Ipsilateral MEPs, which may have comprised summation of early ipsilaterally conducted components and transcallosally or deep white matter stimulated components, can show larger amplitudes than those derived purely from contralateral motor cortex stimulation. We tested this hypothesis using two stimulating positions. We compared intraoperative MEPs in 14 neurologically normal subjects undergoing scoliosis surgery using total intravenous anesthetic regimens. Methods: Trancranial electrical stimulation was applied with both cross scalp (C3C4 or C4C3) or midline (C3Cz or C4Cz) positions. The latter was assumed to be more focal and result in little transcallosal/deep white matter stimulation. A train of 5 square wave stimuli 0.5 ms in duration at up to 200 mA was delivered with 4 ms (250 Hz) interstimulus intervals. Averaged supramaximal MEPs were obtained from the tibialis anterior bilaterally. Results: The cross scalp stimulating position resulted in supramaximal MEPs that were of significantly higher amplitude, shorter latency and required lower stimulating intensity to elicit overall (Wilcoxon Signed Rank test, p < 0.05 for all), as compared to the midline stimulating position. However, no significant differences were found for all 3 parameters comparing ipsilaterally and contralaterally recorded MEPs (p > 0.05 for all), seen for both stimulating positions individually. Conclusions: Our findings suggest that cross scalp stimulation resulted in MEPs obtained ipsilaterally and contralaterally which may be contributed to by summation of ipsilateral and simultaneous transcallosally or deep white matter conducted stimulation of the opposite motor cortex. Use of this stimulating position is advocated to elicit MEPs under operative circumstances where anesthetic agents may cause suppression of cortical and spinal excitability. Although less focal in nature, cross scalp stimulation would be most suitable for infratentorial or spinal surgery, in contrast to supratentorial neurosurgical procedures.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] "Quadripolar" Transcranial Electrical Stimulation for Motor Evoked Potentials
    Schwartz, Stephanie L.
    Kale, Emily B.
    Madden, Dennis
    Husain, Aatif M.
    JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2022, 39 (01) : 92 - 97
  • [2] TRANSCRANIAL MAGNETIC MOTOR-EVOKED POTENTIALS IN SCOLIOSIS SURGERY
    GLASSMAN, SD
    ZHANG, YP
    SHIELDS, CB
    JOHNSON, JR
    LINDEN, RD
    ORTHOPEDICS, 1995, 18 (10) : 1017 - 1023
  • [3] Optimal parameters of transcranial electrical stimulation for intraoperative monitoring of motor evoked potentials of the tibialis anterior muscle during pediatric scoliosis surgery
    Azabou, E.
    Manel, V.
    Andre-Obadia, N.
    Fischer, C.
    Mauguiere, F.
    Peiffer, C.
    Lofaso, F.
    Shils, J. L.
    NEUROPHYSIOLOGIE CLINIQUE-CLINICAL NEUROPHYSIOLOGY, 2013, 43 (04): : 243 - 250
  • [4] Transcranial electrical stimulation technique for induction of unilateral motor evoked potentials
    Yamada, Shoto
    Enatsu, Rei
    Ishikawa, Shu
    Kimura, Yusuke
    Komatsu, Katsuya
    Chaki, Tomohiro
    Akiyama, Yukinori
    Mikami, Takeshi
    Mikuni, Nobuhiro
    CLINICAL NEUROPHYSIOLOGY, 2023, 150 : 194 - 196
  • [5] A Response to: "Quadripolar" Transcranial Electrical Stimulation for Motor-Evoked Potentials
    Bamford, Jeremy
    JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2023, 40 (02) : 187 - 187
  • [6] Monitoring of motor evoked potentials with high intensity repetitive transcranial electrical stimulation during spinal surgery
    Haghighi S.S.
    Journal of Clinical Monitoring and Computing, 2002, 17 (5) : 301 - 308
  • [7] Modification of Motor Evoked Potentials Caused by Electrical Peripheral Nerve Stimulation in Transcranial Magnetic Stimulation
    Hiwaki, Osamu
    Odagaki, Masato
    Fukuda, Hiroshi
    Kodabashi, Atsushi
    Fujimoto, Toshiro
    IEEE TRANSACTIONS ON MAGNETICS, 2008, 44 (11) : 4440 - 4443
  • [8] Peculiarity of soleus motor potentials evoked by transcranial magnetic stimulation and electrical stimulation of tibial nerve
    Wochnik-Dyjas, D
    Glazowski, C
    Niewiadomska, M
    ELECTROMYOGRAPHY AND MOTOR CONTROL-ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1998, 109 (04): : 369 - 375
  • [9] Successful Monitoring of Transcranial Electrical Motor Evoked Potentials With Isoflurane and Nitrous Oxide in Scoliosis Surgeries
    Kempton, Laurence B.
    Nantau, William E.
    Zaltz, Ira
    SPINE, 2010, 35 (26) : E1627 - E1629
  • [10] Pharyngeal motor evoked potentials elicited by transcranial electrical stimulation for intraoperative monitoring during skull base surgery
    Fukuda, Masafumi
    Oishi, Makoto
    Hiraishi, Tetsuya
    Saito, Akihiko
    Fujii, Yukihiko
    JOURNAL OF NEUROSURGERY, 2012, 116 (03) : 605 - 610