ELECTRONICS FOR VERY HIGH-RATE TRACKING DETECTORS

被引:5
|
作者
WILLIAMS, HH
DRESSNANDT, N
EKENBERG, T
GERDS, EJ
NEWCOMER, FM
TEDJA, S
VANBERG, R
VANDERSPEIGEL, J
机构
[1] University of Pennsylvania, Department of Physics, Philadelphia
关键词
D O I
10.1016/0168-9002(95)00088-7
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Results are presented on a system of electronics designed for very high rate tracking detectors at the SSC and LHC. The primary goal was a system for signal detection, time measurement, and readout for the straw tracker for SDC. An integrated circuit incorporating eight channels of amplifier-shaper-discriminator (including detector tail cancellation), and two different integrated circuits for time measurement are described. The performance of tracking measurements up to counting rates of 8 MHz per wire is reported, as well as preliminary results from a baseline restoration circuit.
引用
收藏
页码:146 / 149
页数:4
相关论文
共 50 条
  • [1] Digital centroid-finding electronics for high-rate detectors
    Pietraski, PJ
    Zojceski, Z
    Siddons, DP
    Smith, GC
    Yu, B
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (04) : 810 - 816
  • [2] Digital centroid-finding electronics for high-rate detectors
    Brookhaven Natl Lab, Upton, United States
    IEEE Nucl Sci Symp Med Imaging Conf, (944-950):
  • [3] Digital centroid-finding electronics for high-rate detectors
    Pietraski, P.J.
    Zojceski, Z.
    Siddons, D.P.
    Smith, G.C.
    Yu, B.
    IEEE Transactions on Nuclear Science, 1999, 46 (4 I): : 810 - 816
  • [4] SYSTEM OF PWC ELECTRONICS FOR HIGH-RATE SITUATIONS
    GREEN, DR
    NUCLEAR INSTRUMENTS & METHODS, 1979, 158 (01): : 249 - 260
  • [5] Readout electronics for a high-rate CSC detector
    O'Connor, P
    Gratchev, V
    Kandasamy, A
    Polychronakos, V
    Tcherniatine, V
    Parsons, J
    Sippach, P
    PROCEEDINGS OF THE FIFTH WORKSHOP ON ELECTRONICS FOR LHC EXPERIMENTS, 1999, : 452 - 456
  • [6] The fundamental limitations of high-rate gaseous detectors
    Fonte, P
    Peskov, V
    Ramsey, B
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) : 321 - 325
  • [7] High-rate neutrino detectors for neutrino factories
    King, BJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 451 (01): : 198 - 206
  • [8] Breakdown limit studies in high-rate gaseous detectors
    Ivaniouchenkov, Y
    Fonte, P
    Peskov, V
    Ramsey, BD
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3): : 300 - 304
  • [9] NEW APPROACH TO HIGH-RATE, HIGH-ACCURACY GASEOUS DETECTORS
    CHARPAK, G
    MELCHART, G
    PETERSEN, G
    SAULI, F
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (01) : 186 - 192
  • [10] A SELECTIVE GATE FOR VERY HIGH-RATE ANALOG PULSES
    DIEULOT, JM
    BUSSON, P
    KLUBERG, L
    CALDERO, JC
    GARDIEN, S
    DESCROIX, E
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 314 (01): : 185 - 190