ESTIMATION OF METHODOLOGY AND VALIDATION OF PARTICULATE ENTRAINMENT IN A PILOT-SCALE ROTARY KILN-BASED HAZARDOUS-WASTE INCINERATOR

被引:3
|
作者
ACHARYA, P
PRABHU, S
BARKDOLL, M
机构
[1] IT Corporation, Knoxville, Tennessee, 37923
来源
ENVIRONMENTAL PROGRESS | 1995年 / 14卷 / 01期
关键词
D O I
10.1002/ep.670140121
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Combustion gas particulate entrainment from rotary kiln hazardous waste incinerators (HWI) is a necessary design data requirement because of its impact on the design and operation of the downstream process equipment. The particulate leaving the rotary kiln off-gases may slag in the secondary combustion chamber (SCC). The potential to slag and the problems slagging can cause are dependent upon the SCC burner design, the mineralogical composition of the praticulate, and the SCC operating temperature. Some entrained particulate may adhere to the walls or fall out in the SCC as a dust/slag; the remainder of the particulates will be conveyed by the flue gas to the downstream air pollution control (APC) system. If a wet APC system is used, the particulates would be discharged to a wastewater treatment system (WTS) or publicly operated treatment works (POTW). A literature search was conducted to determine the knowledge base for particulate carry-over from a countercurrent rotary kiln processing sedimentary solids. No data existed for this type soil. A pilot test was, therefore, conducted to experimentally measure the potential entrainment rate of this material. A detailed discussion of the entrainment mechanisms, pilot test equipment, sampling procedure, test conditions simulating the commercial operation, particle size distribution (PSD) of the ash sample, percent carry-over rate, and measured PSD of the kiln particulate carry-over are presented in this article. A mathematical model was developed by the authors to predict the pilot test results. The PSD of incinerator ash was used to calculate percent carry-over rate and PSD of the entrained solids. A comparison of experimental versus estimated results for estimating entrainment are presented in this article.
引用
收藏
页码:44 / 50
页数:7
相关论文
共 7 条
  • [1] EVALUATION OF A PILOT-SCALE CIRCULATING BED COMBUSTOR AS A POTENTIAL HAZARDOUS-WASTE INCINERATOR
    CHANG, DPY
    SORBO, NW
    MURCHISON, GS
    ADRIAN, RC
    SIMEROTH, DC
    JAPCA-THE INTERNATIONAL JOURNAL OF AIR POLLUTION CONTROL AND HAZARDOUS WASTE MANAGEMENT, 1987, 37 (03): : 266 - 274
  • [2] EPAS PILOT-SCALE RESEARCH IN HAZARDOUS-WASTE THERMAL-DESTRUCTION
    LEE, CC
    HUFFMAN, GL
    WASTE MANAGEMENT & RESEARCH, 1987, 5 (01) : 67 - 71
  • [3] Evaluation of a pilot-scale circulating bed combustor as a potential hazardous waste incinerator
    Chang, D.P.Y.
    Sorbo, N.W.
    Murchison, G.S.
    Journal of the Air Pollution Control Association, 1987, 37 (03): : 266 - 274
  • [5] Sensitive in situ detection of CO and O2 in a rotary kiln-based hazardous waste incinerator using 760 nm and new 2.3 μm diode lasers
    Ebert, V
    Teichert, H
    Strauch, P
    Kolb, T
    Seifert, H
    Wolfrum, J
    PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2005, 30 : 1611 - 1618
  • [6] Green Waste/Wood Pellet Pyrolysis in a Pilot-Scale Rotary Kiln: Effect of Temperature on Product Distribution and Characteristics
    Tanoh, Tchini Severin
    Oumeziane, Amina Ait
    Lemonon, Jerome
    Sanz, Francisco Javier Escudero
    Salvador, Sylvain
    ENERGY & FUELS, 2020, 34 (03) : 3336 - 3345
  • [7] An efficient method for computational flow-based simulation of heat transfer in a rotary kiln with pilot scale validation
    Witt, Peter J.
    Johnson, Julian
    Schwarz, M. Philip
    APPLIED THERMAL ENGINEERING, 2022, 214