IN-LINE FIBER OPTIC POLARIMETER WITH A 99-PERCENT COUPLER

被引:3
|
作者
SCHOLL, B [1 ]
STEIN, T [1 ]
NEUES, A [1 ]
MERTENS, K [1 ]
机构
[1] RHEIN WESTFAL TH AACHEN,D-52056 AACHEN,GERMANY
关键词
POLARIZATION ANALYSIS AND MEASUREMENT; IN-LINE POLARIMETER; MONOMODE FIBER;
D O I
10.1117/12.202088
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A polarization transformer in combination with a polarization analyzer is well suited for the generation of any wanted polarization state. We describe the setup, calibration, and applications of an in-line fiber optic polarization detector (IPD) built with a fiber optic coupler of 99% coupling ratio. At the low power output port we use standard beamsplitters and polarizers to generate four different polarization dependent signals. For calibration, the polarization is measured at the high-power output port with an off-line polarimeter (OPD). This enables the determination of the system matrix, which represents the relation between the polarization at the high-power port and the four signals at the low-power port. With this system matrix, a continuous and accurate determination of the polarization at the high-power output port is possible.
引用
收藏
页码:1669 / 1672
页数:4
相关论文
共 50 条
  • [1] In-line fiber-optic polarimeter using a fused 1x5 star coupler
    Lee, SM
    Pan, WP
    Yang, CJ
    [J]. FIBER OPTIC AND LASER SENSORS XIV, 1996, 2839 : 133 - 143
  • [2] 99-PERCENT GOOD
    HAYES, AE
    [J]. ELECTRONIC DESIGN, 1978, 26 (07) : 20 - 20
  • [3] In-line polarimeter using blazed fiber gratings
    Westbrook, PS
    Strasser, TA
    Erdogan, T
    [J]. IEEE PHOTONICS TECHNOLOGY LETTERS, 2000, 12 (10) : 1352 - 1354
  • [4] High bandwidth in-line polarization maintaining fiber polarimeter
    Mikhailov, V.
    Dunn, S.
    Westbrook, P. S.
    [J]. 2010 23RD ANNUAL MEETING OF THE IEEE PHOTONICS SOCIETY, 2010, : 724 - 725
  • [5] A 99-PERCENT GAIN IN JUST 9 MONTHS
    KNOWLTON, W
    [J]. FORTUNE, 1995, 132 (09) : 225 - 225
  • [6] 99-PERCENT PERSPIRATION + PLIGHT OF THE PROFESSIONAL HISTORY WRITER
    HUTTON, R
    [J]. HISTORY TODAY, 1985, 35 (DEC) : 4 - 5
  • [7] DO ONE PERCENT OF FOREST FIRES CAUSE 99-PERCENT OF THE DAMAGE
    STRAUSS, D
    BEDNAR, L
    MEES, R
    [J]. FOREST SCIENCE, 1989, 35 (02) : 319 - 328
  • [8] In-line fiber-optic light filter
    Perry, AS
    Murray, GM
    [J]. APPLIED SPECTROSCOPY, 2003, 57 (06) : 722 - 723
  • [9] Ultracompact metasurface in-line polarimeter
    Mueller, J. P. Balthasar
    Leosson, Kristjan
    Capasso, Federico
    [J]. OPTICA, 2016, 3 (01): : 42 - 47
  • [10] THIS UNIT WILL CUT RESIN DRYING TIME BY 99-PERCENT
    SMOLUK, GR
    [J]. MODERN PLASTICS, 1986, 63 (02): : 48 - 52