EXPERIMENTAL HYALINE CARTILAGE LESIONS - 2-DIMENSIONAL SPIN-ECHO VERSUS 3-DIMENSIONAL GRADIENT-ECHO MR IMAGING

被引:18
|
作者
ADAM, G
NOLTEERNSTING, C
PRESCHER, A
BUHNE, M
BRUCHMULLER, K
KUPPER, W
GUNTHER, RW
机构
[1] Department of Diagnostic Radiology, University of Technology,Aachen, Aachen, 5100, Pauwelsstrasse
[2] Department of Anatomy, University of Technology, Aachen, 5100, Pauwelsstrasse
[3] Animal Research Laboratory, University of Technology, Aachen, 5100, Pauwelsstrasse Aachen
来源
关键词
CARTILAGE; KNEE; ABNORMALITIES; ARTHRITIS; MR STUDIES; RAPID IMAGING; 3-DIMENSIONAL IMAGING;
D O I
10.1002/jmri.1880010608
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The value of magnetic resonance (MR) imaging, with two-dimensional (2D) spin-echo and FISP (fast imaging with steady-state precession) and FLASH (fast low-angle shot) three-dimensional (3D) gradient-echo sequences, for the detection of hyaline cartilage defects of the femoral condyle and the tibial plateau, was investigated in an animal model. In eight dogs, the anterior cruciate ligament was transected in one knee joint. resulting in rapid development of osteoarthritis with degeneration of the hyaline cartilage. At autopsy, 24 cartilage lesions were found, which were classified into four grades. The overall detection of cartilage lesions with MR imaging was poor. Only five of the 24 lesions were visible on 2D spin-echo images, while 11 of 24 were visible on 3D FISP images and 15 of 24 were seen on 3D FLASH images. The best results were obtained in advanced stages of cartilage degeneration, involving ulceration and complete abrasion of the cartilage layer. Signal loss or signal intensity increase in the cartilage layer was seen inconsistently in grades 3 and 4 degeneration. In this animal model, 2D spin-echo imaging was inadequate for the diagnosis of hyaline cartilage lesions, while 3D gradient-echo imaging permitted satisfactory diagnosis in only grade 4 cartilage disease.
引用
收藏
页码:665 / 672
页数:8
相关论文
共 50 条
  • [1] MR CHOLANGIOPANCREATOGRAPHY - COMPARISON BETWEEN 2-DIMENSIONAL FAST SPIN-ECHO AND 3-DIMENSIONAL GRADIENT-ECHO PULSE SEQUENCES
    REINHOLD, C
    GUIBAUD, L
    GENIN, G
    BRET, PM
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (04): : 379 - 384
  • [2] MR-IMAGING OF THE KNEE IN THE SAGITTAL PROJECTION - COMPARISON OF 3-DIMENSIONAL GRADIENT-ECHO AND SPIN-ECHO SEQUENCES
    REEDER, JD
    MATZ, SO
    BECKER, L
    ANDELMAN, SM
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (03) : 537 - 540
  • [3] MR LESION ENHANCEMENT - SPIN-ECHO VERSUS GRADIENT-ECHO - REPLY
    RAND, S
    MARAVILLA, KR
    SCHMIEDL, U
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1995, 16 (03) : 611 - 612
  • [4] MR IMAGING OF PARKINSON DISEASE WITH SPIN-ECHO AND GRADIENT-ECHO SEQUENCES
    BRAFFMAN, BH
    GROSSMAN, RI
    GOLDBERG, HI
    STERN, MB
    HURTIG, HI
    HACKNEY, DB
    BILANIUK, LT
    ZIMMERMAN, RA
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1988, 9 (06) : 1093 - 1099
  • [5] MR IMAGING OF PARKINSON DISEASE WITH SPIN-ECHO AND GRADIENT-ECHO SEQUENCES
    BRAFFMAN, BH
    GROSSMAN, RI
    GOLDBERG, HI
    STERN, MB
    HURTIG, HI
    HACKNEY, DB
    BILANIUK, LT
    ZIMMERMAN, RA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (01) : 159 - 165
  • [6] INTRACRANIAL LESION ENHANCEMENT WITH GADOLINIUM - T1-WEIGHTED SPIN-ECHO VERSUS 3-DIMENSIONAL FOURIER-TRANSFORM GRADIENT-ECHO MR IMAGING
    MIROWITZ, SA
    RADIOLOGY, 1992, 185 (02) : 529 - 534
  • [7] MUSCULOSKELETAL MR-IMAGING - TURBO (FAST) SPIN-ECHO VERSUS CONVENTIONAL SPIN-ECHO AND GRADIENT-ECHO IMAGING AT 0.5-TESLA
    VAHLENSIECK, M
    LANG, P
    SEELOS, K
    SZE, DYH
    GRAMPP, S
    REISER, M
    SKELETAL RADIOLOGY, 1994, 23 (08) : 607 - 610
  • [8] THEORETICAL-ANALYSIS OF GADOPENTETATE DIMEGLUMINE ENHANCEMENT IN T1-WEIGHTED IMAGING OF THE BRAIN - COMPARISON OF 2-DIMENSIONAL SPIN-ECHO AND 3-DIMENSIONAL GRADIENT-ECHO SEQUENCES
    MUGLER, JP
    BROOKEMAN, JR
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (05): : 761 - 769
  • [9] GRADIENT-ECHO MR IMAGING OF THE LUMBAR SPINE - COMPARISON WITH SPIN-ECHO TECHNIQUE
    WATANABE, AT
    TEITELBAUM, GP
    LUFKIN, RB
    TSURUDA, JS
    JINKINS, JR
    BRADLEY, WG
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (03) : 410 - 414
  • [10] SUSCEPTIBILITY ARTIFACTS IN SPIN-ECHO AND GRADIENT-ECHO IMAGING
    POSSE, S
    AUE, WP
    JOURNAL OF MAGNETIC RESONANCE, 1990, 88 (03): : 473 - 492