REALIZATION AND VERIFICATION OF 3-DIMENSIONAL CONFORMAL RADIOTHERAPY WITH MODULATED FIELDS

被引:157
|
作者
BORTFELD, T
BOYER, AL
SCHLEGEL, W
KAHLER, DL
WALDRON, TJ
机构
[1] UNIV TEXAS,MD ANDERSON CANC CTR,DEPT RADIAT PHYS,HOUSTON,TX 77030
[2] DEUTSCH KREBSFORSCHUNGSZENTRUM,FORSCHUNGSSCHWERPUNKT RADIOL FS05,NEUENHEIMER FELD 280,D-69120 HEIDELBERG,GERMANY
关键词
CONFORMAL RADIOTHERAPY; MULTILEAF COLLIMATORS; OPTIMIZATION; INVERSE PROBLEM; 3-DIMENSIONAL TREATMENT PLANNING;
D O I
10.1016/0360-3016(94)90366-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: We describe the experimental demonstration of the delivery of a three-dimensional conformal radiotherapy dose distribution using in-field modulation of nine fixed-gantry fields. Methods and Materials: Two-dimensional in-field modulation profiles, varying from field to field, were realized by quasi-dynamic multileaf collimation using the prototype of a commercially available multileaf collimator installed on a medical linear accelerator. The profiles were calculated to deliver an optimal dose distribution for a patient with a prostate carcinoma. The target volume surface was invaginated and bifurcated. The calculated dose distribution was delivered to a homogeneous polystyrene phantom consisting of 1 cm thick slices that were cut to match the patient's outer contour. Seven therapy verification films were placed between the phantom slices. Results: Analysis of the films revealed a degree of conformation of the high-dose region to the target shape that would not be possible with unmodulated conformal therapy. However, small observed spatial displacements of the dose distribution confirm the need for very accurate positioning. Conclusions: It is feasible to deliver clinically relevant, three-dimensional dose distributions that conform to invaginated and bifurcated target volumes using fields modulated by multileaf collimators.
引用
收藏
页码:899 / 908
页数:10
相关论文
共 50 条
  • [1] Comparison of 3-dimensional conformal radiotherapy and intensity modulated radiotherapy for breast cancer
    Kivanc, H.
    Gultekin, M.
    Yildiz, F.
    Gurkaynak, M.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S189 - S189
  • [2] Target dose conformity in 3-dimensional conformal radiotherapy and intensity modulated radiotherapy
    Wu, VWC
    Kwong, DLW
    Sham, JST
    RADIOTHERAPY AND ONCOLOGY, 2004, 71 (02) : 201 - 206
  • [3] Comment on: "Target dose conformity in 3-dimensional conformal radiotherapy and intensity modulated radiotherapy"
    Ozyigit, G
    Selek, U
    RADIOTHERAPY AND ONCOLOGY, 2005, 74 (01) : 78 - 78
  • [4] Estimating the costs of intensity-modulated and 3-dimensional conformal radiotherapy in Ontario
    Yong, J. H. E.
    McGowan, T.
    Redmond-Misner, R.
    Beca, J.
    Warde, P.
    Gutierrez, E.
    Hoch, J. S.
    CURRENT ONCOLOGY, 2016, 23 (03) : E228 - E238
  • [5] Results and prognostic factors of 3-dimensional conformal radiotherapy and intensity-modulated radiotherapy for esophageal carcinoma
    Tan, L.
    Xiao, Z.
    Zhang, H.
    Chen, D.
    Feng, Q.
    Zhou, Z.
    Lv, J.
    Liang, J.
    Hui, Z.
    Wang, L.
    Yin, W.
    NEOPLASMA, 2015, 62 (05) : 777 - 786
  • [6] Comparison of Intensity-Modulated Radiotherapy and 3-Dimensional Conformal Radiotherapy as Adjuvant Therapy for Gastric Cancer
    Minn, A. Yuriko
    Hsu, Annie
    La, Trang
    Kunz, Pamela
    Fisher, George A.
    Ford, James M.
    Norton, Jeffrey A.
    Visser, Brendan
    Goodman, Karyn A.
    Koong, Albert C.
    Chang, Daniel T.
    CANCER, 2010, 116 (16) : 3943 - 3952
  • [7] 3-dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: Dosimetric and radiobiologic analysis
    Bhardwaj, A. K.
    Kehwar, T. S.
    Chakarvarti, S. K.
    Oinam, A. S.
    Sharma, S. C.
    IRANIAN JOURNAL OF RADIATION RESEARCH, 2007, 5 (01): : 1 - 8
  • [8] Effectiveness Of Intensity Modulated Versus 3-Dimensional Conformal Radiotherapy In Stage Iii Lung Cancer
    Kale, M. S.
    Bonomi, M. R.
    Mhango, G.
    Wisnivesky, J. P.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2013, 187
  • [9] Intensity Modulated Radiation Therapy Replaces 3-Dimensional Conformal Radiotherapy as Prostate Cancer Treatment
    Elliott, Sean P.
    Adejoro, Oluwakayode O.
    Konety, Badrinath R.
    Jarosek, Stephanie L.
    Dusenbery, Kathryn E.
    Virnig, Beth A.
    JOURNAL OF UROLOGY, 2012, 187 (04): : 1253 - 1258
  • [10] POSTPROSTATECTOMY 3-DIMENSIONAL CONFORMAL RADIOTHERAPY - RESPONSE TO TREATMENT
    WATSON, GA
    SANDLER, HM
    MCLAUGHLIN, PW
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 : 280 - 281