Comparative analysis of corneal morphological changes after transversal and torsional phacoemulsification through 2.2 mm cornel incision

被引:12
|
作者
Assaf, Ahmed [1 ]
Roshdy, Maged Maher [1 ]
机构
[1] Ain Shams Univ, Ophthalmol Dept, Cairo, Egypt
来源
CLINICAL OPHTHALMOLOGY | 2013年 / 7卷
关键词
cornea; endothelium; transversal phacoemulsification; torsional phacoemulsification; Ellips(TM); FX; OZIL((R)); IR;
D O I
10.2147/OPTH.S39019
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: This paper compares and evaluates the corneal morphological changes occurring after cataract surgery through a 2.2 mm corneal incision. We use two platforms for comparison and evaluation, transversal and torsional phacoemulsification. Patients and methods: This study includes 139 consecutive cataractous eyes ( nuclear color 2-4, according to the Lens Opacities Classification System III [LOCSIII]) of 82 patients undergoing cataract surgery through a 2.2 mm' corneal incision. Two different phacoemulsification platforms were used and assigned randomly: we used the WhiteStar Signature ((R)) system with the Ellips (TM) FX transversal continuous ultrasound (US) mode for group I (mean age: 65.33 +/- 6.97 years), and we used the Infiniti ((R)) system with the OZil ((R)) Intelligent Phaco (IP) torsional US mode for group II (mean age: 64.02 +/- 7.55 years). The corneal endothelium and pachymetry were evaluated preoperatively and at 1 month postoperatively. Incision size changes were also evaluated. Results: All surgeries were uneventful. Before intraocular lens implantation, the mean incision size was 2.24 +/- 0.06 mm in both groups (P=.75). In terms of corneal endothelial cell density, neither preoperative ( I vs II: 2304.1 +/- 122.5 cell/mm(2) vs 2315.6 +/- 83.1 cell/mm(2), P +/- 0.80) nor postoperative (I vs II: 2264.1 +/- 124.3 cell/mm(2) vs 2270.3 +/- 89.9 cell/mm(2), P +/- 0.98) differences between the groups were statistically significant. The mean endothelial cell density loss was 1.7% +/- 1.6% and 2.0%+/- 1.4% in groups I and II, respectively. Furthermore, no significant differences between groups I and II were found preoperatively (P=0) and postoperatively (P=.68) in central pachymetry. With surgery, the mean increase in central pachymetry was 28.1 +/- 23.6 mu m and 24.0 +/- 24.0 mu m in groups I and II, respectively (P=0.1). Conclusion: Ellips (TM) FX transversal and OZil ((R)) IP torsional phacoemulsification modes are safe for performing cataract surgery, inducing minimal corneal thickness and endothelial changes.
引用
收藏
页码:55 / 61
页数:7
相关论文
共 50 条
  • [1] Comparison of corneal endothelial changes following phacoemulsification with transversal and torsional phacoemulsification machines
    Atas, Mustafa
    Demircan, Suleyman
    Hashas, Arzu Seyhan Karatepe
    Gulhan, Ahmet
    Zararsiz, Gokmen
    [J]. INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2014, 7 (05) : 822 - 827
  • [2] Comparison of corneal endothelial changes following phacoemulsification with transversal and torsional phacoemulsification machines
    Mustafa Atas
    Süleyman Demircan
    Arzu Seyhan Karatepe Hashas
    Ahmet Gülhan
    Gkmen Zararsιz
    [J]. International Journal of Ophthalmology, 2014, (05) : 822 - 827
  • [3] Polynomial Curve Fitting of the Corneal Profile in 2.2-mm Corneal Incision Phacoemulsification
    Tejedor, Jaime
    Gutierrez-Carmona, Francisco J.
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2015, 31 (01) : 42 - +
  • [4] Phakonit: Phacoemulsification through a 0.9 mm corneal incision
    Agarwal, A
    Agarwal, A
    Agarwal, S
    Narang, P
    Narang, S
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (10): : 1548 - 1552
  • [5] Corneal topographic changes after phacoemulsification through steep axis incision
    Acar S.
    Mavi E.
    Cosar C.B.
    Sakaoglu N.
    [J]. International Ophthalmology, 2004, 25 (2) : 123 - 128
  • [6] Comparative analysis of coaxial phacoemulsification with 2.2-and 2.8-mm clear corneal incisions
    Sethi, Harinder Singh
    Saluja, Komal
    Naik, Mayuresh P.
    [J]. INTERNATIONAL OPHTHALMOLOGY, 2018, 38 (01) : 215 - 222
  • [7] Comparative analysis of coaxial phacoemulsification with 2.2- and 2.8-mm clear corneal incisions
    Harinder Singh Sethi
    Komal Saluja
    Mayuresh P. Naik
    [J]. International Ophthalmology, 2018, 38 : 215 - 222
  • [8] Corneal profile on-axis polynomial curve fitting in 2.2-mm incision for phacoemulsification
    Tejedor, Jaime
    Gutierrez-Carmona, Francisco J.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [9] Corneal biomechanical properties changes after coaxial 2.2-mm microincision and standard 3.0-mm phacoemulsification
    Zhe Zhang
    Hua Yu
    Hui Dong
    Li Wang
    Ya-Ding Jia
    Su-Hua Zhang
    [J]. International Journal of Ophthalmology, 2016, (02) : 230 - 234
  • [10] Corneal biomechanical properties changes after coaxial 2.2-mm microincision and standard 3.0-mm phacoemulsification
    Zhang, Zhe
    Yu, Hua
    Dong, Hui
    Wang, Li
    Jia, Ya-Ding
    Zhang, Sa-Hua