MEMBRANE MODEL FOR NEUTRAL-CARRIER-BASED MEMBRANE ELECTRODES CONTAINING IONIC SITES

被引:93
|
作者
EUGSTER, R [1 ]
SPICHIGER, UE [1 ]
SIMON, W [1 ]
机构
[1] SWISS FED INST TECHNOL,DEPT ORGAN CHEM,UNIV STR 16,CH-8092 ZURICH,SWITZERLAND
关键词
D O I
10.1021/ac00054a007
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The selectivity characteristics of neutral-carrier-based electrodes can be improved to a large extent by the optimization of the ionic sites/carriers ratio. A new membrane model and a new equation for the emf response of such membranes are introduced. They illustrate the dependence of the emf response on the activity of free carriers available. As a case of practical importance the emf function of a magnesium ion-selective electrode is discussed. It demonstrates that the emf function normally deviates from the Nikolsky-type behavior and that transient potentials and long-term drifts occur and therefore make the selectivity determination according to the separate solution method questionable. The measured data are in good agreement with the values calculated on the basis of the reported model.
引用
收藏
页码:689 / 695
页数:7
相关论文
共 50 条
  • [1] SELECTIVITY-MODIFYING INFLUENCE OF ANIONIC SITES IN NEUTRAL-CARRIER-BASED MEMBRANE ELECTRODES
    EUGSTER, R
    GEHRIG, PM
    MORF, WE
    SPICHIGER, UE
    SIMON, W
    ANALYTICAL CHEMISTRY, 1991, 63 (20) : 2285 - 2289
  • [2] NEUTRAL-CARRIER-BASED ION-SELECTIVE ELECTRODES
    OGGENFUSS, P
    MORF, WE
    OESCH, U
    AMMANN, D
    PRETSCH, E
    SIMON, W
    ANALYTICA CHIMICA ACTA, 1986, 180 : 299 - 311
  • [3] Potentiometric Response of a Neutral-carrier-based Membrane to Aqueous Mercury in Cl−-rich Media
    Yunmi Kim
    Jongwon Kim
    Kyoung Nam Kim
    Suk-Kyu Chang
    Taek Dong Chung
    Analytical Sciences, 2009, 25 : 567 - 570
  • [4] Potentiometric Response of a Neutral-carrier-based Membrane to Aqueous Mercury in Cl--rich Media
    Kim, Yunmi
    Km, Jongwon
    Kim, Kyoung Nam
    Chang, Suk-Kyu
    Chung, Thek Dong
    ANALYTICAL SCIENCES, 2009, 25 (04) : 567 - 570
  • [5] OPTIMIZING PERMSELECTIVITY FOR NEUTRAL CARRIER MEMBRANE ELECTRODES
    LEWIS, SB
    BUCK, RP
    ANALYTICAL LETTERS, 1976, 9 (05) : 439 - 449
  • [6] LIFETIME OF NEUTRAL-CARRIER-BASED LIQUID MEMBRANES IN AQUEOUS SAMPLES AND BLOOD AND THE LIPOPHILICITY OF MEMBRANE-COMPONENTS
    DINTEN, O
    SPICHIGER, UE
    CHANIOTAKIS, N
    GEHRIG, P
    RUSTERHOLZ, B
    MORF, WE
    SIMON, W
    ANALYTICAL CHEMISTRY, 1991, 63 (06) : 596 - 603
  • [7] AMMONIUM-SELECTIVE NEUTRAL CARRIER MEMBRANE ELECTRODES
    DEGAWA, H
    SHINOZUKA, N
    HAYANO, S
    NIPPON KAGAKU KAISHI, 1980, (10) : 1462 - 1468
  • [8] SELECTIVITY OF NEUTRAL CARRIER-PVC MEMBRANE ELECTRODES
    MASCINI, M
    PALLOZZI, F
    ANALYTICA CHIMICA ACTA, 1974, 73 (02) : 375 - 382
  • [9] Iodide selective membrane electrodes based on a Molybdenum-Salen as a neutral carrier
    Ghanei-Motlagh, Masoud
    Taher, Mohammad Ali
    Ahmadi, Kyoumars
    Sheikhshoaie, Iran
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2011, 31 (08): : 1625 - 1631
  • [10] NEUTRAL-CARRIER-BASED MAGNESIUM-SELECTIVE ELECTRODE
    ROUILLY, MV
    BADERTSCHER, M
    PRETSCH, E
    SUTER, G
    SIMON, W
    ANALYTICAL CHEMISTRY, 1988, 60 (19) : 2013 - 2016