Patient specific cup anteversion in total hip arthroplasty: a computed tomography study investigating the use of the transverse acetabular ligament to control cup placement

被引:3
|
作者
Archbold, H. A. P. [1 ]
Slomczykowski, M. [2 ]
Cairns, H. [1 ]
Eckman, Kort [3 ]
Jaramaz, Branislav [4 ]
Beverland, D. E. [1 ]
机构
[1] Musgrave Pk Hosp, Outcomes Unit, Belfast BT9 7JB, Antrim, North Ireland
[2] Johnson & Johnson Co, DePuy Int, Leeds LS11 0EA, W Yorkshire, England
[3] Carnegie Mellon Univ, Robot Inst, Pittsburgh, PA 15213 USA
[4] Western Penn Hosp, Inst Comp Assisted Surg, Pittsburgh, PA USA
来源
CURRENT ORTHOPAEDIC PRACTICE | 2009年 / 20卷 / 01期
关键词
acetabular component orientation; transverse acetabular ligament;
D O I
10.1097/BCO.0b013e3181944dd2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Ensuring optimal position of the acetabular component during total hip arthroplasty is a complex problem. Although computer assisted techniques have been developed to achieve this, these systems may result in improper cup alignment caused by errors in registration of the anterior pelvic plane. Furthermore, set goals for cup placement do not reflect the variation in acetabular morphology. Aneed exists to developamethodfor cuppositioning that is patient specific and eliminates the need to register the anterior pelvic plane. It is our hypothesis that the transverse acetabular ligament can be used to do this. The objective of this study was to define the version of acetabular components placed using this technique. Methods In this series of 40 consecutive primary hip replacements, the transverse acetabular ligament was used as the sole method to define cup version. Postoperative CT scans of the pelvis were analyzed tomeasure the anteversion of the acetabular component. Results At a minimum follow-up of 12 months (range 12-18 months), none of the hips dislocated. Using the transverse acetabular ligament as the sole method to control the version of the acetabular component resulted in an average radiographic anteversion of 19.78 +/- 8.18 (mean +/- standard deviation) which equates to an operative anteversion of 28.18 +/- 11.38 (mean +/- standard deviation). Conclusions This paper highlights the variation in cup version when the transverse acetabular ligament is used to establish and control cup placement. This questions the one-size-fits-all philosophy of a set goal for cup positioning.
引用
收藏
页码:73 / 76
页数:4
相关论文
共 50 条
  • [1] Reliability of the transverse acetabular ligament as a landmark for functional cup anteversion in total hip arthroplasty
    Jassim, Shivan S.
    Bhatia, Tejasvi
    McMahon, Jack R. D.
    Pierrepont, Jim W.
    McMahon, Stephen J.
    HIP INTERNATIONAL, 2024, 34 (05) : 608 - 613
  • [2] COMPUTED-TOMOGRAPHY MEASUREMENT OF ACETABULAR CUP ANTEVERSION AND RETROVERSION IN TOTAL HIP-ARTHROPLASTY
    MIAN, SW
    TRUCHLY, G
    PFLUM, FA
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1992, (276) : 206 - 209
  • [3] The transverse acetabular ligament may be used to align the acetabular cup in total hip arthroplasty
    Pearce, C. J.
    Sexton, S. A.
    Davies, D. C.
    Khaleel, A.
    HIP INTERNATIONAL, 2008, 18 (01) : 7 - 10
  • [4] Transverse Acetabular Ligament as an Anatomical Landmark for Intraoperative Cup Anteversion in Primary Total Hip Replacement
    Salal, Mohammed Hatem
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2017, 27 (10): : 642 - 644
  • [5] Is transverse acetabular ligament a reliable guide for aligning cup anteversion in total hip arthroplasty?: A measurement by CT arthrography in 90 hips
    Yoon, Byung-Ho
    Ha, Yong-Chan
    Lee, Young-Kyun
    Jo, Woo-Lam
    Lee, Kyoung-Min
    Koo, Kyung-Hoi
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2016, 21 (02) : 199 - 204
  • [6] Anteversion of the Acetabular Component Aligned With the Transverse Acetabular Ligament in Total Hip Arthroplasty
    Miyoshi, Hideaki
    Mikami, Hiroshi
    Oba, Koichi
    Amari, Rui
    JOURNAL OF ARTHROPLASTY, 2012, 27 (06): : 916 - 922
  • [7] Novel Measure of Acetabular Cup Inclination and Anteversion During Total Hip Arthroplasty
    Walter, William L.
    Baker, Neri A.
    Marsden-Jones, Daniel
    Sadeghpour, Ameneh
    MEDICAL DEVICES-EVIDENCE AND RESEARCH, 2022, 15 : 1 - 14
  • [8] A new method for the measurement of anteversion of the acetabular cup after total hip arthroplasty
    Aydogan M.
    Burç H.
    Saka G.
    European Journal of Orthopaedic Surgery & Traumatology, 2014, 24 (6) : 897 - 903
  • [9] Is transverse acetabular ligament an anatomical landmark to reliably orient the cup in primary total hip arthroplasty?
    Viste, A.
    Chouteau, J.
    Testa, R.
    Cheze, L.
    Fessy, M. -H.
    Moyen, B.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2011, 97 (03) : 241 - 245
  • [10] A new radiographic acetabular cup anteversion measurement method in total hip arthroplasty: a clinical study
    Saka, G.
    Altun, G.
    Burc, H.
    Aydogan, M.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2019, 29 (04): : 813 - 818