IRREVERSIBLE DROP OF SYSTEMIC VASCULAR RESISTANCES IN PATIENTS IMPLANTED WITH A JARVIK TOTAL ARTIFICIAL-HEART

被引:4
|
作者
DELEUZE, P [1 ]
LOISANCE, DY [1 ]
SHIIYA, N [1 ]
WAN, F [1 ]
HILLION, ML [1 ]
BENVENUTI, C [1 ]
HEURTEMATTE, Y [1 ]
CACHERA, JP [1 ]
机构
[1] HOP HENRI MONDOR,CNRS,URA 1431,CTR RECH CHIRURG,SERV CHIRURG CARDIOTHORAC,F-94010 CRETEIL,FRANCE
来源
关键词
TOTAL ARTIFICIAL HEART; SYSTEMIC VASCULAR RESISTANCES; MULTIORGAN FAILURE;
D O I
10.1177/039139889101400508
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Maintenance of the body's perfusion by a total artificial heart (TAH) may result in physiological alterations to the circulatory system. Little has been said about modifications to systemic vascular resistances (SVR) during TAH assistance. This paper reports on two patients implanted with a Jarvik - 70 cc TAH, who died after 1 and 3 days, both with an irreversible drop of SVR related to a complete loss of vascular tone but not related to sepsis. Activation of multiple cascades of inflammation, triggered by the extracorporeal circulation (ECC), is maintained during TAH support. Desperately sick patients might not be able to face the vaso-active situations created by the inflammatory response.
引用
收藏
页码:286 / 289
页数:4
相关论文
共 50 条
  • [1] EVALUATION OF DIRECT EFFECTS OF ENOXIMONE ON SYSTEMIC AND PULMONARY VASCULAR BED IN ANIMALS WITH A JARVIK TOTAL ARTIFICIAL-HEART
    DELEUZE, PH
    RANDE, JLD
    OKUDE, J
    WAN, F
    BRUNET, S
    THORAVAL, FR
    CACHERA, JP
    LOISANCE, DY
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1992, 103 (03): : 589 - 594
  • [2] ANALYSIS OF CIRCULATING MICROPARTICLES IN A PATIENT ON A JARVIK TOTAL ARTIFICIAL-HEART
    KEON, WJ
    ADAMS, GA
    LABOW, B
    [J]. CLINICAL AND INVESTIGATIVE MEDICINE-MEDECINE CLINIQUE ET EXPERIMENTALE, 1987, 10 (04): : B50 - B50
  • [3] NATIVE RIGHT ATRIAL TAMPONADE WITH THE JARVIK TOTAL ARTIFICIAL-HEART
    LINDEN, P
    STEIN, K
    PRISTAS, J
    KORMOS, RL
    GRIFFITH, BP
    [J]. CHEST, 1991, 99 (06) : 1523 - 1525
  • [4] HEMODYNAMIC CHARACTERISTICS OF THE JARVIK-7 TOTAL ARTIFICIAL-HEART
    KAWAGUCHI, A
    MUNERETTO, C
    PAVIE, A
    SOLIS, E
    LEGER, P
    GANDJBAKHCH, I
    BORS, V
    DESRUENNES, M
    CABROL, A
    CABROL, C
    [J]. CIRCULATION, 1989, 80 (05) : 152 - 157
  • [5] THE IMPLANTED TOTAL ARTIFICIAL-HEART - IMAGING PERSPECTIVES
    ARMSTRONG, JD
    DEVRIES, WC
    JOYCE, LD
    ANDERSON, FL
    [J]. INVESTIGATIVE RADIOLOGY, 1983, 18 (04) : S34 - S34
  • [6] ARTIFICIAL-HEART PROGRAMS TO GROW - JARVIK
    CHERSKOV, M
    JARVIK, R
    [J]. HOSPITALS, 1986, 60 (12): : 70 - 71
  • [7] SURGICAL IMPLANTATION OF THE JARVIK-5 TOTAL ARTIFICIAL-HEART IN A CALF
    FUKUMASU, H
    IWAYA, F
    OLSEN, DB
    LAWSON, JH
    KOLFF, WJ
    [J]. TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1979, 25 : 232 - 238
  • [8] THE JARVIK-7 TOTAL ARTIFICIAL-HEART IS PRELOAD AND AFTERLOAD DEPENDENT
    GOLDENBERG, IF
    WALKER, M
    ROELLER, SK
    GOBEL, FL
    JOYCE, L
    JORGENSEN, CR
    MADISON, JD
    PEDERSEN, WR
    [J]. CIRCULATION, 1987, 76 (04) : 404 - 404
  • [9] ORTHOTOPIC TRANSPLANTATION AFTER IMPLANTATION OF A JARVIK-7 TOTAL ARTIFICIAL-HEART
    CABROL, C
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1989, 97 (03): : 342 - 350
  • [10] PERMANENT IMPLANTATION OF THE JARVIK-7 TOTAL ARTIFICIAL-HEART - A CLINICAL PERSPECTIVE
    LAWRIE, GM
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1988, 259 (06): : 892 - 893