THE PRODUCTION OF XE-127 VIA (NAT)XE(P,XN)CS-127-]XE-127

被引:1
|
作者
NORTIER, FM
MILLS, SJ
STEYN, GF
机构
[1] National Accelerator Centre, Faure, 7131
关键词
D O I
10.1016/0969-8043(93)90106-K
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Effective cross-sections for the production of Cs-127 in the bombardment of (nat)Xe with protons were measured from threshold up to 100 MeV. From the integral excitation function obtained, yield curves for Xe-127, produced via the (nat)Xe(p,xn)Cs-127 --> Xe-127 route, were derived for a full range of ps target thicknesses. These curves can be used for the optimization of the production of Xe-127 within specific practical incident energy and target thickness constraints. The expected optimum yield for a representative production gas target (1.64 g/cm2 thick) is 6.7 MBq/muAh (obtained at an incident energy of 39.3 MeV).
引用
收藏
页码:1494 / 1496
页数:3
相关论文
共 50 条
  • [1] RADIATIONS OF XE-127
    FORREST, RN
    EASTERDAY, HT
    [J]. PHYSICAL REVIEW LETTERS, 1958, 1 (09) : 352 - 352
  • [2] RADIATIONS OF XE-127
    FORREST, RN
    EASTERDAY, HT
    [J]. PHYSICAL REVIEW, 1958, 112 (03): : 950 - 954
  • [3] SOME WAYS OF PRODUCTION FOR XE-127
    BIEVELEZ, P
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1983, 8 (05): : A44 - A44
  • [4] COST CONSIDERATIONS FOR XE-127
    MERRICK, MV
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1991, 32 (08) : 1642 - 1642
  • [5] EXPERIENCE WITH XE-127 VENTILATION IMAGING
    SMALL, DR
    RAILTON, R
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1985, 11 (2-3): : A35 - A35
  • [6] LEVELS OF XE-127 FROM BETA-DECAY OF CS-127
    WELLS, JC
    HENRY, EA
    MEYER, RA
    [J]. BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1975, 20 (09): : 1188 - 1188
  • [7] IMPROVED XENON IMAGES WITH XE-127
    HOFFER, PB
    HARPER, PV
    BECK, RN
    STARK, V
    KRIZEK, H
    HECK, L
    LEMBARES, N
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1973, 14 (03) : 172 - 174
  • [8] COLLIMATOR AND XE-127 FOR VENTILATION STUDIES
    CHU, RYL
    ZIELINSKI, FW
    ING, SJ
    POE, ND
    [J]. RADIOLOGY, 1980, 137 (03) : 819 - 823
  • [9] HEALTH-PHYSICS OF XE-127
    CHU, RYL
    POE, ND
    ZIELINSKI, FW
    ING, SJ
    [J]. RADIOLOGY, 1980, 134 (02) : 493 - 495
  • [10] AN ORIGINAL PREPARATION METHOD OF XE-127
    MOUADILIA, A
    VERNOIS, J
    ISABELLE, DB
    [J]. APPLIED RADIATION AND ISOTOPES, 1995, 46 (6-7) : 597 - 598